Eaton-Williams ICUS30 Скачать руководство пользователя страница 17

 

 

ICUS CONDENSING UNIT INSTALLATION MANUAL 

 

 

Jan 09:F\Qualitair Eng\Icu\Manuals\0412118S 

 

 

 

 

 

 

17

 

 

C

C

 

 

E

E

 

 

 

 

 

 

C

C

 

 

E

E

 

 

R

R

 

 

T

T

 

 

I

I

 

 

F

F

 

 

I

I

 

 

C

C

 

 

A

A

 

 

T

T

 

 

E

E

 

 

 

Eaton-Williams Air Conditioning 

(Eaton-Williams Ltd) 

Station Road – Edenbridge - Kent - TN8 6EG - England 

Telephone ... 44 (0)1732 866055 

Telefax ... (0)1732 863461 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Qualitair 

 

Edenaire 

 

Moducel

 

 

We declare that the equipment designated below, 

on the basis of design and construction in the form marketed by us and 

when installed and operated in accordance with our information and instructions, 

conforms to the EMC Directive, the PED and the essential Health and Safety requirements of the Machinery 

Directive. 

 

If alterations are made to this equipment without our approval, 

this declaration becomes invalid.  Furthermore, this equipment may be 

assembled into other systems which may also constitute machinery and shall 

not be put into service until the assembled system has been declared in conformity 

with the Machinery Directive. 

 
 

 

Model    

 

 

 

 

Serial N° 

 

 

 

 

Standards Applied 

 

 

 

 

 

 

BS EN 292-Pt2 

 

 

EMC 

 

 

BS EN50081-1   

 

 

EMC 

 

 

BS EN50082-1   

 

 

Low Voltage  

 

EN60204 pt1 

 

 

Pressure Equipment 

prEN14276-2 

 
 

 

Controls Applied  

BS EN ISO 9001: 1994 

 

 

 

 

 

BSI Registered Company Q5026 

 

 

 
 

 

 

Gerry Stapley 

 

 

Gary Martin

 

 

 

 

  

Managing Directors 

 

ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 

89/336/EEC 

 

MACHINERY DIRECTIVE 

EC Declaration of Conformity 

As Defined by the EC Council Directive on Machinery 

 

89/392/EEC Annex IIA and amended by 

91/368/EEC - 93/44/EEC & 93/68/EEC 

Содержание ICUS30

Страница 1: ...INSTALLATION MANUAL ICUS CONDENSING UNIT IF SUPPLIED AS A SYSTEM ICC QLC PLEASE REFER TO INDOOR UNIT INSTALLATION MANUAL Eaton Williams Ltd Oldfields Business Park Birrell Street Fenton ST4 3ES Tel 4...

Страница 2: ...ce Connection 5 3 4 Air Entry 5 4 Outdoor Unit Access 6 4 1 Access Details Fixings 6 5 General Service Connection 7 6 Power Control Connections 8 6 1 Wiring up the unit 9 6 2 Wiring Requirements 9 6 3...

Страница 3: ...hazards are kept to a minimum 3 The equipment has been fitted with doors and covers to prevent access during operation These must be kept in place and additional guards fitted if necessary 4 The equip...

Страница 4: ...S Wall Bracket Option Kit The unit is supplied complete with axial fan and guard hermetic compressor shut off service valves fan speed controller low pressure switch high pressure switch winter start...

Страница 5: ...ided in the base of the unit to secure the unit to a suitable plinth or to the wall mount bracket kit If required the contractor should install the unit on anti vibration pads 3 3 Service Connections...

Страница 6: ...anel 5 Removable top panel Front and side access screw fixings 6 Service access panel Front access screw fixings 7 Reversing valve Heat pump unit only HP LP cut outs Remove service access panel 8 Elec...

Страница 7: ...up charge m 5m 25g 25g 40g 40g Refrigerant Connection Sizes Refer to Section 8 for Extended Pipework ICUS30 ICUS40 ICUS55 ICUS80 Liquid 7 1 1 4 1 4 3 8 3 8 Suction 7 2 5 8 5 8 5 8 3 4 Mains Power Cabl...

Страница 8: ...8 6 POWER CONTROL CONNECTIONS ICUS SINGLE PHASE COOLING ONLY ICUS Terminal Customer Connections PE Customer Earth Connection E N Customer Neutral Connection L Customer Live Connection C Cooling Signal...

Страница 9: ...ing Wiring Power and signal cables run between outdoor and indoor unit Details of the fuse ratings and cable requirements are given in the tables in Section 5 Page 7 of this manual 6 3 Terminations De...

Страница 10: ...refrigerant lines are adequately supported using refrigerant pipe clips 7 3 Unit Connections The ICUS unit connections are terminated in male flare connections as detailed in the tables in Section 5...

Страница 11: ...itional Charge ICUS30 Suction 3 8 5 8 Suction 3 8 5 None 5m 25g m Liquid Liquid ICUS40 Suction 5 8 5 8 5 8 Suction 8 None 5m 25g m Liquid Liquid ICUS55 Suction 5 8 5 8 5 8 5 8 Suction 10 None 5m 40g m...

Страница 12: ...Manuals 0412118S 12 Fitting Pipe Size 3 8 5 8 45 Bend 0 12 0 15 0 18 0 21 90 Bend Short Radius 0 37 0 43 0 49 0 55 90 Bend Long Radius 0 24 0 27 0 30 0 37 180 Bend Short Radius 0 73 0 91 1 10 1 28 18...

Страница 13: ...d 3 System Isolation After achieving the specified system vacuum close the gauge low pressure port 5 and switch off the vacuum pump Leave the system for 1 hour and check that the vacuum is maintained...

Страница 14: ...icular protection of lungs eyes and skin from refrigerants dust etc Only approved lifting gear and power tools should be used and access to the work area be restricted to authorised personnel Disconne...

Страница 15: ...Has correct HRC external fusing isolating been installed 5 Has additional extended pipe run refrigerant charge been measured into the system where necessary or heat pumps been charged correctly 6 Is...

Страница 16: ...e diagrams themselves are supplied with the unit and are located in the electrical section Please ensure the correct issue drawing is used with the relevant system refer to supplier if necessary Unit...

Страница 17: ...Machinery Directive If alterations are made to this equipment without our approval this declaration becomes invalid Furthermore this equipment may be assembled into other systems which may also const...

Страница 18: ...Eng Icu Manuals 0412118S 18 OLDFIELDS BUSINESS PARK BIRRELL STREET FENTON ST4 3ES TEL 01782 597124 FAX 01782 316633 AN EATON WILLIAMS COMPANY As part of the policy of continuous product improvement w...

Отзывы: