7
2.
TONEARM SETTING
a)
VTA adjustment
To set the Vertical Tracking Angle, first put a record on the platter. When the needle is lowered
into the record groove, the tube of the tonearm should be parallel to the surface of the record.
If it is not, loosen both hexagonal screws in the tonearm base just enough to allow vertical
movement of the arm pillar without force, and slide the arm up or down until it is parallel.
Carefully and evenly retighten the hexagon screws
without applying excessive force
(which
could deform the arm pillar).
F-Note tonearm has two stage VTA adjustment. Once you set VTA by moving main tonearm
pillar up and down, you can unlock fine adjustment with locking screw shown on following
illustration.
With needle in the record groove, carefully move tonearm up or down with main VTA
adjustment crew. When you are satisfied with VTA setting, carefully retighten VTA locking
screw and move tonearm to the tonearm rest position.