1. Operational principle

The ultrasonic humidifying device adopts electronic overclocking shock (oscillation
frequency is 1.7 MHz, more than human hearing range, no harm to human and
animal), through the high frequency resonance of ceramic chip, it will make the water
leaving the cover to create the water mist shape, no need to heat or chemical to
produce 1 to 5 um water particles floating in the air, thereby to improve the air quality
and improve the environment.

2. Configuration and technical parameters

Model

EW-030HDA

Mist capacity

30 L/hour

Содержание EW-030HDA

Страница 1: ... Configuration and technical parameters 2 3 Filter installation and cleaning 3 4 Installation instruction 3 5 Atomization system 5 6 Regular failure and failure elimination 7 7 Maintenance 9 8 Precautions 9 9 After sales service 10 Please read this carefully before using and keep it for reference Easywell Electronic Co Ltd ...

Страница 2: ...o harm to human and animal through the high frequency resonance of ceramic chip it will make the water leaving the cover to create the water mist shape no need to heat or chemical to produce 1 to 5 um water particles floating in the air thereby to improve the air quality and improve the environment 2 Configuration and technical parameters Model EW 030HDA Mist capacity 30 L hour ...

Страница 3: ...stem of the equipment more effectively and prevent the entry of impurities to affect the atomization system please install the water filter and ensure that every interface with no waster leakage and air leakage Clean the filter element according to the local actual water conditions generally 1 2 months or so to clean the filter element impurities or replacement Turn on the water filter bottle take...

Страница 4: ...located in the position of the PVC pipe cross section level up 30 degrees or so the best diameter of the out put fog hole are 20 to 30mm the spacing between the outlet hole of the fog is depends on the length of the pipe for example if the single pipe length is 12m the spacing should be with 15 20cm Please also block off the end of the pipe so as to avoid water accumulation in the pipeline the lev...

Страница 5: ...otherwise the equipment will be easily damaged by the dripping of fog droplets and the short cycle of moisture will lead to the failure of components The worst result is cause accidents It is recommended that the equipment be separated from the humidifying room where the humidity is higher than 85 RH 5 Atomizing system The indicator light is green when powered up and is red when working The indica...

Страница 6: ...ace a new atomizer or atomized ceramic wafers energy exchange wafers The replacing method of atomizing plate is as follow see fig 11 图 11 Fig 11 Operation as following a Cut off the power drain the water from the tank and dry the water on the surface of the atomizer b Unscrew the pressure ring with the lock piece remove the old atomizer chip and keep the atomizer chamber clean c When install the n...

Страница 7: ...cuit b Remove the foreign matter in the float c The pressure must reach 5KG Don t stop when adding water a The water float is displaced b There is foreign matter in the float c The float is damaged a Adjust it to the correct position b Remove the foreign matter c Replace the float No fog outlet a The voltage 5 lower than the standard b The water is too hard c Too dirty in the tank a Check the powe...

Страница 8: ...r 2 Water tank cleaning clean the water tank regularly Turn off and uplog the machine before cleaning so as to avoid contact incident 3 Cleaning method Turn the fixing screw on the cover of the water tank and open the tank cover plate please pay attention to the circuit connection inside use a soft cotton close or brush to clean Dish soap is available see Fig 12 The scale and other foreign matter ...

Страница 9: ...in out the water if the machine is out of working for long time 8 Please don t dig hole on the cover of the machine directly when install the water filter 9 The power supply must be cut off if the machine stop working over 48 hours and the water storage in the tank must be drained out entirely As if the storage water stocked too long time it will become ropy this will affect the function of the eq...

Страница 10: ...e equipment We give 1 year warranty for the whole machine in the warranty period as a result of the failure problem of the product quality our after sales will give free maintenance The artificial damage and the damage caused by the irresistible force are not covered in the warranty We will charge a trend in the maintenance if the machine is not be operated correctly Please use clean water If the ...