background image

page 18

Using Your EasyStand

Standing

• Please consult with your therapist or doctor before starting a standing program. 

• Once transferred into the EasyStand, position your feet and the knee support and secure any 

straps. Push the pump handle forward with 15-25 strokes. The seat will slowly rise into the 

standing position. Remember that you can stop the seat anywhere between the sitting and 

standing position. 

• To return to the seated position, move and hold the pump handle 

toward the rear until you have reached your desired position. The seat 

will slowly lower until you release the handle.

• If you have difficulty getting the seat to lower, you may not be applying 

the proper pressure to the handle.

• If you have difficulty reaching the handle, you may consider 

purchasing the actuator handle extension.

• If you have difficulty getting the seat to lower, check to see that you have the seat tube and 

the back adjustment tube set at the same color-coded setting. Failure to do this may cause 

serious damage to your unit!  

• If the unit is in the standing position and nobody is in it, apply moderate pressure to the seat 

of the unit while holding the pump handle back. Do not use excessive force.

low

er

rais

e

Содержание 5000 YOUTH

Страница 1: ...Owner s Manual 5000 YOUTH ...

Страница 2: ...Table of Contents Introduction 1 Safety Precautions 2 Assembly 3 15 Using Your EasyStand 16 19 Parts Options 20 40 Health Benefits 41 User Log 42 Specifications 43 Limited Warranty 44 ...

Страница 3: ...rtant and necessary that you inspect your EasyStand 5000 YOUTH periodically to assure that it is in safe operating condition Minor adjustments can be made by the operator However replacement of worn parts major adjustments or any other important corrections should be handled by an authorized dealer or service center Only Altimate Medical Inc approved replacement parts should be used to ensure safe...

Страница 4: ...reposition the foot holders while you are in the standing position Consult with your therapist or doctor for proper foot placement and angle If the unit was exposed to temperatures of less than 50 F 23 5 C you must allow the unit to warm to room temperature before use Use body weight to lower the seat Do not use excessive force The EasyStand is for indoor use only Extreme movement in the EasyStand...

Страница 5: ...kage Manyofthepicturesinthis manualshowtheoptionalratchet handles Youmayhavethe standardknobs If you ordered the high back extension the anti tips must be installed with the rear level glides as shown Tighten securely If you ordered level glides turn the level glides into the threaded holes in the back of the base and tighten securely Insert end caps 1 2 3 page 3 Assembly ...

Страница 6: ...vel glide and the adapter pointing outward After attaching adapter thread the level glide in securely If you ordered the high back extension the anti tips must be installed with the rear casters as shown Tighten securely If you ordered the formed table and casters thread the casters into the front and rear and tighten securely Caution The casters must be threaded all the way in 4 5 6 page 4 Assemb...

Страница 7: ...rs into the back of the unit as in figure 5 or 6 page 4 then install the drive wheels into the front Tighten securely If you ordered the Mobile Option refer to the assembly instructions you received If you ordered the optional table swing away sleeve mount it before installing the table frame It can be mounted on the right or left side Put the quick pin back into the other side Only one quick pin ...

Страница 8: ...ition when not in use to avoid possible injury If you ordered the independent adjustable kneepad slide the notch onto the pegs of the lower table H frame Note Table H frame must be installed properly for kneepad to function Caution Keep kneepad in the lower position when not in use to avoid possible injury 10 12 11 page 6 Assembly Be sure that H frame bracket is facing inward Independent Knee Stan...

Страница 9: ...tips must be installed as in step 7 Insert the table into the H frame and push the spring button to continue installation Tighten the knobs or the optional ratchet handles Note Spring button indi cates the highest allowable table adjustment There is only one spring button Attach the front pad and tighten securely 13 14 15 page 7 Assembly ratchet han dles or knobs ...

Страница 10: ...t side Attach the actuator handle so that the handle is near vertical Use the enclosed allen wrench and a multi use wrench Tighten Securely If you ordered the removable actuator handle it can be removed by loosening the knob as shown 16 17 18 page 8 Assembly ...

Страница 11: ... tube into the corresponding seat adjustment tube Depress the spring button to insert and continue until you here a click Note If colors do not match damage to the unit will occur when going to the standing position Be sure that the colors on the following arm and the seat adjustment tube are the same If colors are not the same damage will occur to the unit when raised to the standing position Tig...

Страница 12: ...or handle The bolts for the seat are found in the seat Remove bolts and place the seat onto the frame narrow end toward the rear of the unit Tighten securely Lower the seat by applying weight and pulling back gently on the actuator handle 22 23 24 page 10 Assembly ...

Страница 13: ...own is side support with optional padded hip guide Note If you ordered the high back extension go to 27 Attach the back pad and tighten securely If you ordered the high back extension slide it into the back frame before installing the lower back Then install the lower back pad with the attached bolts Tighten Securely 25 26 27 page 11 Assembly ...

Страница 14: ...then tighten securely If you ordered the high back extension with the optional chest vest it comes assembled Install it like you would the high back If you ordered the chest vest with the low back attach it to the back frame as shown Tighten Securely 28 29 30 page 12 Assembly ...

Страница 15: ...e high back extension with laterals install the high back onto the unit then attach lower backpad and laterals as shown Tighten securely Caution Lateral rod must extend through clamp as shown The universal headrest receiver can be used with a variety of other manufactures headrests Headrest receiver will snap down into maximum height position Depress again to lower headrest Tighten quick adjust kn...

Страница 16: ...e Stealth Otto Bock or Whitmyer M0012 detachable mount you must remove the auxiliary mounting plate If you are using the Whitmyer detachable mount fig A remove the chrome insert and knob then insert it into the universal headrest receiver as shown and secure with knob Note If you do not have a knob supplied by Whitmyer use the included buttonhead bolt 34 35 36 page 14 Assembly fig A ...

Страница 17: ...he two of the provided buttonhead bolts to fasten their hardware as shown Here is the 5000 Youth shown with casters ratchet handles padded hip guides table swing away sleeve clear desk table independent kneepads anti tips and back option 37 page 15 Assembly ...

Страница 18: ... loosen the quick adjust handles on each foot holder clamp When you find the desired foot position tighten the handles securely To adjust the height loosen the same quick adjust handle of the foot holder clamp Loosen the factory adjusted bolt on the outside of each clamp only if necessary Now the clamps will slide up with 9 of adjustment Tighten securely MOBILE OPTION Do not use the mobile option ...

Страница 19: ...s Secure the foot straps and reposition the knee and side supports If required many patient lifts can be used for transfers Remove the front table assembly of the EasyStand and transfer in from the front or use the removable back option and transfer from the rear To transfer with a sliding board position your chair parallel to the EasyStand and flip the side support and knee support back Be sure t...

Страница 20: ... have reached your desired position The seat will slowly lower until you release the handle If you have difficulty getting the seat to lower you may not be applying the proper pressure to the handle If you have difficulty reaching the handle you may consider purchasing the actuator handle extension If you have difficulty getting the seat to lower check to see that you have the seat tube and the ba...

Страница 21: ... not exceed the rated weight capacity of the equipment for which this hydraulic unit is used on the weight limit for the EasyStand 6000 is 280 lbs If your EasyStand was shipped to you during or exposed to a temperature of less then 50 degrees Fahrenheit you must allow the hydraulic unit to warm up to room temperature before any use Failure to follow this step could damage the unit and render it in...

Страница 22: ...page 20 Parts Detail 5000 YOUTH OPTION OVERVIEW EasyStand Parts Detail 1 14 26 27 28 28 33 33 29 30 30 37 37 40 43 42 34 29 38 40 38 45 44 41 31 31 31 41 44 44 44 42 41 41 34 32 32 43 36 35 36 35 page ...

Страница 23: ...page 21 Parts Detail 5000 YOUTH BASIC FRAME ...

Страница 24: ...page 22 Parts Detail LEVEL GLIDES 10126 LOCKING CASTERS 5062 ...

Страница 25: ...page 23 Parts Detail ACTUATOR HANDLE 58483 MOBILE OPTION 5200Y ...

Страница 26: ...page 24 Parts Detail ACTUATOR HANDLE EXTENSION 5022 REMOVABLE ACTUATOR HANDLE 5020 ...

Страница 27: ...page 25 Parts Detail FOOT STRAPS 80634 FOOT HOLDERS 80635 SECURE FOOT OPTION 80616 ...

Страница 28: ...page 26 Parts Detail STANDARD KNEE PAD 10128 INDEPENDENT KNEE PADS 5026 ...

Страница 29: ...page 27 Parts Detail BLACK MOLDED TABLE 10600 CLEAR DESK TABLE 5041 ...

Страница 30: ...page 28 Parts Detail OVERSIZED TABLE OPTION 5040 NO TABLE OPTION 5250 ...

Страница 31: ...page 29 Parts Detail TILT TABLE FOR MOLDED TABLE 81011 TILT TABLE FOR OVERSIZED TABLE 80997 ...

Страница 32: ...page 30 Parts Detail TILT TABLE FOR CLEAR TABLE 80996 ROHO SEAT SET 81020 ...

Страница 33: ...page 31 Parts Detail TABLE SWING AWAY SLEEVE 5024 ARM TROUGHS 5030 ...

Страница 34: ...page 32 Parts Detail BACK OPTION 5100Y ...

Страница 35: ...page 33 Parts Detail REMOVABLE BACK OPTION 5100YR ...

Страница 36: ...HIGH BACK W CHEST STRAP 5150 LATERAL SUPPORTS 5036 page 34 Parts Detail ...

Страница 37: ...HIGH BACK UNIVERSAL RECEIVER 80643 HIGH BACK HEAD SUPPORT 5032 BACK HEAD SUPPORT 7030 BACK UNIVERSAL RECEIVER 80642 page 35 Parts Detail ...

Страница 38: ...UNIVERSAL HEADREST RECEIVER 80608 SHOULDER RETRACTORS 5034 page 36 Pats Detail ...

Страница 39: ...page 37 Parts Detail NO BACK OPTION 58582 HIP GUIDES 5038Y ...

Страница 40: ...page 38 Parts Detail LARGE CHEST STRAP 51600 SMALL CHEST STRAP 51601 MEDIUM CHEST VEST 80632 LARGE CHEST VEST 80633 SMALL CHEST VEST 80631 ...

Страница 41: ...page 39 Parts Detail SEAT BELT 51500 ...

Страница 42: ...icity allowing for improved positioning and comfort Strengthen cardiovascular and respiratory systems Range of motion spine hips knees ankles to prevent contractures Pressure relief through changing positions S t a n d i n g O c c a s i o n a l l y S h o r t T e r m B e n e f i t s L o n g T e r m B e n e f i t s S t a n d i n g O f t e n IMPROVED HEALTH THROUGH STANDING ...

Страница 43: ...User Log photo copy this page for a long term record of your standing progress Client Name Start Time Date End Time Total Time page 41 User Log ...

Страница 44: ...64cm Specifications page 42 Specifications Height Range Weight Limit Seat Depth Range from front pivot Seat Height from Floor transfer height Seat to Footplate Range Table Frontpad Depth Range from seat when standing Table Height Range from seat pivot Kneepad Depth Range Knee Width from front of seat Footprint Weight of Basic Unit Frame Color Standard Upholstery Color Black Table Size Desk Table S...

Страница 45: ... to our factory without prior authorization LIMITATIONS AND EXCLUSIONS The foregoing warranty shall not apply to serial numbered products if the serial number has been removed or defaced Products subject to negligence abuse misuse improper operation improper maintenance improper storage or damages beyond AMl s control are not covered by this warranty and that evaluation will be solely determined b...

Страница 46: ...6393 Fax Free 877 342 8968 or 507 697 6900 email info easystand com www easystand com Standing technology should only be used under the guidance of a physician with recommendations for standing program protocol and any medical precautions Standing programs should be monitored by the attending therapist AMI maintains a policy of continual product improvement and reserves the right to change feature...

Отзывы: