Appendix C – LCD Display Messages
-C-5-
R
A
I D
F
a
i l
C
o
d
e
1
<
1
3
X
4
>
“Code 1” represents the disk sequence is wrong with current sequence
displayed within <>.
Examples:
<2134>: disk 2 and disk 1 sequence is reversed.
<13x4>: the original disk 3 is put into tray 2 and the original
disk 2 is not plugged or failed.
<423s>: the spare disk is put in the tray 4 and original disk 4 is
put in the tray 1
R
A
I D
F
a
i l
C
o
d
e
2
“Code 2” represents the array has been failed but of 4 disk exist.
RAID configuration error message:
The following two messages will be displayed alternatively when the
setting of RAID level selectors does not match the existing disk RAID
level setting:
R
A
I D
L
e v
e l
U
n
m
a
t c
h
e
d
C u
r
r
e
n
t
:
R 5
O
r
i
g
i
n
a l
:
R
0
The system will stop working until users choose one of the following
options:
Shut down ERS4-FWTT and tune the RAID level selectors to
R5
Re-plug the four disks and re-create the RAID to R0 (but data
in the R5 disks will be lost)