background image

3

2 Basic Configuration

This chapter describes disk array system connections and disk installation.

Unpacking

Contact your supplier if any of the following items are missing or damaged

.

Caution

The disk array system is heavy. Be careful when lifting and moving it.

easyRA

ID Q12

PS-F4R

2

4G Fibre Channel to SAS

Dis

k A

rray

 Sy

ste

m

Hardware User Manual

Power 

P/S Fai

l Acces

s

Ente

r      

        

ESC

        

    Pr

i/Sec

easyRA

ID Q12PS-F4R

2

4G Fibre Channel to SAS

Dis

k A

rray

 Sy

ste

m

Software User Manual

Power 

P/S Fai

l Acces

s

Ente

r      

        

ESC

        

    Pr

i/Sec

Power Cables

Front Panel Keys

Hardware and software user Manuals

Disk Array System

RS-232 Cable

HDD Screw pack

Rails

Rail Extenders

Fix Screw pack M5

Fix Screw pack 
UNC #10-32

Fix Screw pack M6

Содержание Q12PS-F4R2

Страница 1: ...easyRAID Q12PS F4R2 Hardware User Manual 42 30000 5103 4G Fibre Channel to SAS Disk Array System Version 1 0 ...

Страница 2: ......

Страница 3: ...easyRAID Q12PS F4R2 4G Fibre Channel to SAS Disk Array System Hardware User Manual ...

Страница 4: ......

Страница 5: ...ts 4 Closed Front Panel 4 Open Front Panel 5 Disk Tray 6 Rear View 7 Installing Disks 8 Making Connections 10 Connecting the Host Interface 10 Connecting the GUI management port 11 Connecting the JBOD enclosure 11 Connecting and Turning on the Power 12 Mounting in a Rack 13 Installing the Rail Extenders 14 Chapter 3 Maintenance Replacing a Disk 15 Replacing a Power Supply 16 Upgrading Memory 18 Re...

Страница 6: ......

Страница 7: ...umentation are protected by copyright and are distributed under licenses restricting their use copying and distribu tion No part of this documentation may be reproduced in any form by any means with out prior written authorization and its licensors if any Conventions Caution This symbol is used to remind users to pay attention to important descriptions regarding usage and maintenance repair or add...

Страница 8: ...isk array system on an unstable cart stand or table It may fall causing serious damage to the product Keep the disk array system away from magnetic forces Do not use the disk array system near water Keep the disk array system away from dust sand or dirt Gaps and openings in the cabinet are provided for venti lation Never block or cover these openings because the disk array system may overheat and ...

Страница 9: ...nd openings since they may touch dangerous voltage points and cause a risk of fire or electric shock Unplug the power cord from the wall outlet before clean ing Keep the disk array system dry Do not use liquid cleaners aerosol cleaners or a wet cloth Use a damp cloth for cleaning Except as specifically explained in this User Manual do not attempt to service the disk array system by yourself Openin...

Страница 10: ... Supply Safety Notes To avoid electric shocks do not use an extended power cord or an outlet that does not match the disk array system plug or leaves the plug exposed The disk array system has a 3 wire grounded plug The third pin connects to ground do not remove it If the power cord or plug is damaged or worn unplug it immediately and contact a qualified service technician for maintenance To avoid...

Страница 11: ...ect sunlight a flat stable surface capable of supporting the disk array system Host Interface 4G Fibre Channel The easyRAID Q12PS F4R2 has dual 4 Gbit fibre channel interfaces with SFP connec tors for linkage to a fibre channel switch or host computer interface card With the cor rect SFP transceiver and optical cable the following transmission distances can be achieved Hard Disk Interface Serial A...

Страница 12: ...nal settings Ethernet settings easyRAID Q12PS F4R2 supports DHCP Dynamic Host Configuration Protocol to get a IP address or a default IP is 192 168 0 1 You could find it from LCD scrolling easyRAID Q12PS F4R2 had embedded CGI based GUI graphic user interface management interface can be easily accessed through a web browser Item Required Setting Connection Serial Port COM1 or COM2 Protocol RS232 As...

Страница 13: ...easyRAID Q12PS F4R2 4G Fib re Ch an ne l to SA S Dis k Arr ay Sys tem Ha rdwa re Us er Ma nu al Power P S FailAccess Enter ESC Pri Sec easyRAID Q12PS F4R2 4G Fib re Ch an ne l to SA S Dis k Arr ay Sys tem So ftw are Us er Ma nu al Power P S FailAccess Enter ESC Pri Sec Power Cables Front Panel Keys Hardware and software user Manuals Disk Array System RS 232 Cable HDD Screw pack Rails Rail Extender...

Страница 14: ...l indicator Indicates a failed power supply 4 Host computer access indicator Indicates data transfer between the disk array sys tem and the host computer 5 Up function button Moves up in the LCD menus 6 Down function button Moves down in the LCD menus 7 Enter function button Selects a menu item or confirms a choice or entry 8 Escape function button Returns to the previous LCD menu without making c...

Страница 15: ...ion 1 12 Disk trays 1 12 Removable hot swap disk trays 13 Front panel door Protects the disks and houses the LCD panel Disk1 Disk2 Disk3 Disk4 Disk5 Disk6 Disk7 Disk8 Disk9 Disk10 Disk11 Disk12 Disk Mapping Color Status Bule Access Green Disk Online Red No Disk Tray LED Indication 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Страница 16: ...isk Tray No Name Description 1 Power Error indicator LED Different colors indicate different disk states Green Disk online Orange Disk fail Red No disk 2 Access indicator LED This blue LED indicates that the disk is being accessed 3 Tray handle Releases the disk tray 2 1 Front 3 ...

Страница 17: ...ing fan 2 System cooling fan 6 Power Supply 2 Removable redundant power supply 2 7 Power Supply Handle For power supply removal 8 Power Supply AC In Connects to a 100 240 VAC power source 9 Host Port 1 Primary fibre channel Connects to the host server 10 Host Port 2 Secondary fibre channel Connects to the host server 11 Ethernet Port Used for browser based configuration 12 Expansion Port Used for ...

Страница 18: ... open 2 Push the button A to release the disk tray handle Pull the handle B to release the tray 3 Align the rear of the disk with the rear of the disk tray 4 Insert the disk into the disk tray and fix into place with screws supplied with the disk Disk1 Disk2 Disk3 Disk4 Disk5 Disk6 Disk7 Disk8 Disk9 Disk10 Disk11 Disk12 Disk Mapping Color Status Bule Access Green Disk Online Red No Disk Tray LED I...

Страница 19: ...t A then slowly close the disk tray handle B 6 Repeat steps 2 to 5 until all of the required disks have been installed 7 Push the front panel door closed and lock it A Disk1 Disk2 Disk3 Disk4 Disk5 Disk6 Disk7 Disk8 Disk9 Disk10 Disk11 Disk12 Disk Mapping Color Status Bule Access Green Disk Online Red No Disk Tray LED Indication ...

Страница 20: ...ace The disk array system has dual fibre channel interfaces Refer to the following sections to make host interface connections The easyRAID Q12PS F4R2 has dual 4 Gbit fibre channel interfaces Each interface can be used with optical or copper transceivers and cables Follow these instructions to make optical connections 1 Insert the LC Optical SFP transceiver A in one of easyRAID Q12PS F4R2 FC ports...

Страница 21: ...I management port by a Ethernet cable standard RJ45 to LAN WAN environment and open a web browser with easyRAID Q12PS F4R2 IP address Default is 192 168 0 1 and DHCP exabled for easily monitoring configuring RAID sys tem Connecting the JBOD enclosure Connect a SAS SFF 8088 miniSAS connector external cable to JBOD enclosure COM UPS COM UPS ...

Страница 22: ...g on the Power 1 Plug a power cable A to a power connector at the rear of the unit then plug the second power supply cable into the second power connector B 2 Switch on both power supply switch C Note The system is equipped with auto switching power supplies that can run on 100 to 240 VAC COM UPS P S2 A B C ...

Страница 23: ...mounting points on the rails 2 Extend both of the rails so that they are the right length to fit in your rack 3 Bolt the rails into the rack using the rack bolts supplied with your rack You will need four nuts and bolts not included for each rail two at the front and two at the back 4 Tighten the locking screws when they are the correct length 5 Slide the disk array system into the rack and bolt i...

Страница 24: ...s to fit the rail extenders if required 1 If required bolt the rail extenders into place as shown using the small bolts pro vided 2 Slide the disk array system into the rack and bolt it into place with the supplied fixing screws Note The rail extenders may be required to allow the disk array system room for the front door to open correctly ...

Страница 25: ...om the disk tray 4 Align the rear of the new disk with the rear of the disk tray 5 Insert the new disk into the disk tray 6 Attach the disk to the disk tray with the screws that came with the disk 7 Slide the disk tray back into the empty slot then close the disk tray handle 8 Push the front panel door closed and lock it Note Turn off the audible alert by pressing the Up and Down function but tons...

Страница 26: ...they can be inserted and removed while the disk array is powered on and operating Follow these instructions to replace a failed power supply 1 Identify the power supply that has failed 2 Remove the power cable from the power supply connector at the rear of the unit 3 Loosen the power supply retaining screw 4 Remove the faulty power supply by pulling the power supply handle A and pressing the relea...

Страница 27: ...easyRAID Q12PS F4R2 SAS Disk Array System 17 3 Maintenance Replacing a Power Supply 6 Tighten the power supply retaining screw 7 Reconnect the power cable COM UPS ...

Страница 28: ... in place slide the controller cage out of the chassis 2 Pull the DIMM retaining clips away from the DIMM the DIMM springs out of the socket Remove the DIMM 3 Gently push the new DIMM into the socket then push the corners of the DIMM down The DIMM is secured by the DIMM retaining clips Push the controller cage back in lower the handle and tighten the retaining screws Note The DIMM module will fit ...

Страница 29: ... appears on the LCD panel where x refers to fan 1 or 2 and an audible alert sounds 1 Identify the FAN module that has failed loosen the retaining screws slide it out of chassis 2 Insert a new FAN module tighten retaining screws Note Turn off the audible alert by pressing the Up and Down function buttons on the front panel twice simultaneously COM UPS COM UPS ...

Страница 30: ......

Страница 31: ...ks Management IO connector 1 x RS 232 COM port 1 x RJ 45 LAN port 10 100 Mbps JBOD Expansion optional Yes Battery Backup Module optional Yes FAN Turbo FAN x 2 Hot Swapable Power Supply Redundant 1 1 350 Watt 100 240 VAC 47 63 Hz 8 4A 10 Over voltage current power and short circuit protection LED indicates power status Output 5V 3 3V 12V Operating Enviroment Temperature 5 C 40 C Warranty 3 year war...

Страница 32: ......

Отзывы: