background image

Replacement Parts

WARNING: The following may cause severe damage to pump and will void warranty:
• 

Using an extension cord

• 

Cutting off the ground pin or using an adapter fi tting

• 

Working on pump or switch while plugged in

• 

Removing motor housing, unscrewing impeller or otherwise removing impeller seal

• 

Pumping chemicals or corrosive liquids

• 

Pumping gasoline or other fl ammable liquids

• 

Piping: Plastic PVC pipe, drain hose, galvanized steel or copper pipe may all be used. All piping must 
be clean and free of all foreign matter to prevent clogging. Use thread compound on all threaded joints 
unless specifi ed otherwise. Be sure to seal the thread connection with tape seal when you are using the 
pipe fi tting to connect the fl ange.

Troubleshooting

Problem

Pump hums

Pump runs but does 

not deliver water

Pump runs but 

delivers only a small 

amount of water

Fuse blows or circuit 

breaker trips when 

pump starts

Motor runs for a short 

time, then stops

Possible Causes

•  Line circuit breaker is off, or fuse is burned or loose. 
•  Water level in sump has not reached turn-on level as indicated in installation drawing on the carton. 
•  Pump cord is not making contact in receptacle. 
•  Float (optional) is stuck. It should operate freely in basin. 
•  If all of the above are OK and then the motor should operate.

•  Check valve (optional) is installed backwards (not included with pump), arrow on valve should point in direction of 

fl ow. 

•  Discharge shut-off valve (if used) may be closed. 
•  Impeller or volute openings are fully or partially clogged, remove pump and clean. 
•  Pump is air-locked, start and stop several times by plugging and unplugging cord, check for clogged vent hole in 

pump case. 

•  Inlet holes in pump base are clogged, remove pump and clean the openings. 
•  Vertical pumping distance is too high or the pipe size is too small, reduce vertical distance or increase the pipe size 

fi ttings.

•  Pump is air-locked, start and stop several times by plugging and unplugging cord, check for clogged vent hole in 

pump case. 

•  Vertical pumping distance is too high or pipe size is too small, reduce vertical distance or increase the pipe size.
•  Inlet holes in pump base are clogged, remove pump and clean the openings. 
•  Impeller or volute openings are fully or partially clogged, remove pump and clean. 
•  Pump impeller is partially clogged with debris, causing motor to run slow and overload, remove pump and clean.

•  Pump impeller is partially clogged with debris causing motor to run slow and overload, remove pump and clean.
•  Motor stator may be defective. 
•  Fuse size or circuit breaker may be too small (must be 15 amps). 
•  Impeller or volute opening are fully or partially clogged, remove pump and clean.

•  Inlet holes in pump base are clogged, remove pump and clean the openings. 
•  Pump impeller is partially clogged with debris causing motor to run slow and overload, remove pump and clean. 
•  Motor stator may be defective.

Содержание TM Series

Страница 1: ...inances The plug and connections should be protected from water rain Before using the pump always inspect it visually especially power cable and plug Do not use the pump if it is damaged If the pump is damaged have it inspected by a qualified service center only Make sure that electric connections are protected from all water and moisture Protect the plug and the power cable from heat oil or sharp...

Страница 2: ...let the pump run as a sump pump The pump power cord should be connected to a separately fused grounded line with a minimum capacity of 15 amps It can be connected to non fuse breaker at the recommended amps Never touch the pump when it is plugged in 1 Before installing or servicing this pump be certain pump power source is disconnected Contact a qualified li censed electrician for disconnecting el...

Страница 3: ...ards not included with pump arrow on valve should point in direction of flow Discharge shut off valve if used may be closed Impeller or volute openings are fully or partially clogged remove pump and clean Pump is air locked start and stop several times by plugging and unplugging cord check for clogged vent hole in pump case Inlet holes in pump base are clogged remove pump and clean the openings Ve...

Страница 4: ...om the produc tion sale use or misuse of this product The manufacturer or supplier shall not be held liable for any loss of fish plants or any other livestock as a result of any failure or defect of this product If you experience a failure of your pump please check the following before returning to us 1 Remove filter housing clean and inspect impellar and surrounding chamber reassemble and test pu...

Отзывы: