4.  

 The top housing is also connected at the handle. 

This can be a little tricky to release. Slightly lift the 

front of the housing and push the top of the handle 

to release the housing.

5.  

 Clean out any debris inside the housing.

6.  

 It may be easier to remove adjustable ball joint at 

this point, but access to the impeller can be made 

with it attached. To remove the adjustable ball 

assembly, loosen the blue nut from the pump.

7.  

 With a Phillips screwdriver remove the four screws 

and two brackets that secure pump body to lower 

housing. Be sure not to lose any screws during 

disassembly.

8.  

 Remove the screw holding the power cord strain 

relief clip.   

9.  

 To access the impeller assembly, remove four 

screws from pump impeller housing.   

10.     Carefully pull the impeller out of its chamber.

11.     Inspect and clean the impeller and chamber. Clean 

the impeller and chamber using water and a damp 

cloth or sponge. A vinegar mixture may help remove 

hard deposits. If the impeller is damaged, replace 

with a new impeller. 

12.     Once the impeller is cleaned or replaced with new 

one, reverse the steps to reassemble the pump and 

housing.

 

 Tip To attach the top housing, start by securing the 

latch at the handle first. Align the top and bottom 

housing sections and squeeze them together at the 

handle to latch them in place. Then secure the four 

clips.

13.     Reattach the plumbing and return the pump back to 

the pond. Plug the pump back in and observe the 

operation to make sure it is working properly. 

Step 7

Step 8

Step 10

Step 12

Step 4

Содержание Eco-Clear EPS1300

Страница 1: ...ical supply before handling maintaining repairing or installing any pond equipment 2 Keep out of the reach of children 3 Always make sure you know the correct amps and voltage required before installing 4 Use dedicated power outlet only Sharing the outlet with other equipment may cause overheating and fire 5 A drip loop should be installed in the power cord to ensure water cannot travel down it an...

Страница 2: ...direction outlet for use with 1 1 1 4 or 1 1 2 kink free or 1 1 2 PVC tubing Ceramic impeller provides high wear resistance and long life Epoxy sealed motor is waterproof safe and reliable Pump can be run continuously 24 hours per day Assembly and General Installation 1 The pump can be placed at the bottom of the pond One end of the hose will connect to the pump outlet and the other will feed a fi...

Страница 3: ...using is closed and properly latched to prevent debris from entering the pump 4 Check the water level daily to ensure the pump remains fully submerged 5 If the pump is left in water but not operating regularly test run it at least once a week 6 Once per season the unit should be disassembled to clean any build up of debris or mineral deposits on the impeller assembly and housing Areas with hard wa...

Страница 4: ...access the impeller assembly remove four screws from pump impeller housing 10 Carefully pull the impeller out of its chamber 11 Inspect and clean the impeller and chamber Clean the impeller and chamber using water and a damp cloth or sponge A vinegar mixture may help remove hard deposits If the impeller is damaged replace with a new impeller 12 Once the impeller is cleaned or replaced with new one...

Страница 5: ...ing very little water Check pump housing or impeller for clogs Check tubing for kinks or obstructions Vertical pumping distance is too high or the pipe size is too small Pond filter needs to be cleaned Low water conditions with pump sucking air For the EPS4900VF adjust flow with the controller It may be necessary to increase the flow volume temporarily and once running smoothly the flow can be low...

Страница 6: ...LEAR PUMP PERFORMANCE DATA Model 0 3 6 9 12 15 18 21 24 COMPATIBLE ECO CLEAR FILTER EPS1300 1400 1125 710 430 150 EC1300 EC1300U EPS2500 2480 1680 1140 815 449 185 EC2600 EC2600U EPS3700 3680 2900 2310 1815 1390 875 180 EC3900 EC3900U EPS4900 4850 4090 3215 2425 1800 1400 832 195 EPS4900VF 4850 4090 3215 2425 1800 1400 832 195 Gallons per hour gph flow at feet of head Pro Tip Maximum performance i...

Страница 7: ...VF pump EPSBK Hose barb replacement Barb Hose Connector Nut Gasket EPSRB Adjustable Rotating Ball Connector with Nut and Gasket EPSPB Pump Bracket Set Includes Large and Small Bracket No screws EC150PVC 1 1 2 Adapter Fitting for PVC not shown Replacement Parts Image for reference only Upper Housing Locking Clip Nut Large Bracket Barb Hose Connector Gasket Adjustable Ball Gasket Pump Small Bracket ...

Страница 8: ...st first be obtained by calling EasyPro at 800 448 3873 or via email at warranty easypro com It is the purchaser s responsibility to pay the return shipping charges Be sure to include the RA number original receipt in the form of an invoice or sales receipt your name your return address and your phone number inside of the package No warranty claims will be honored without the original receipt that...

Отзывы: