background image

EasyIO FS32 – User Reference v1.4 

 

Disclaimer 
 

Confidentiality Notice 

The information contained in this document is confidential information of EasyIO Holdings Pte Ltd. Such 
information and the software described herein, is furnished under a license agreement and may be used 
only in accordance with that agreement. 
The  information  contained  in  this  document  is  provided  solely  for  use  by  EasyIO  Holdings  Pte  Ltd 
employees, licensees, and system owners; and, except as permitted under the below copyright notice, is 
not to be released to, or reproduced for, anyone else. 
While every effort has been made to assure the accuracy of this document, EasyIO Holdings Pte Ltd is not 
responsible  for  damages  of  any  kind,  including  without  limitation  consequential  damages,  arising  from 
the  application  of  the  information  contained  herein.  Information  and  specifications  published  here  are 
current as of the date of this publication and are subject to change without notice. The latest product 
specifications can be found by contacting our corporate headquarters  or support channel.  
 

Trademark Notice 

 
EasyIO logo are registered trademarks of EasyIO Holdings Pte Ltd. 
 
BACnet and ASHRAE are registered trademarks of American Society of Heating, Refrigerating and Air- 
Conditioning Engineers. All other product names and services, mentioned in this publication, that are 
known to be trademarks, registered trademarks, or service marks are the property of their respective 
owners. 
 

Copyright and Patent Notice 

This document may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced 
to any electronic medium or machine-readable form without prior written consent from EasyIO Holdings 
Pte Ltd 
 
Copyright © 2019 EasyIO Holdings Pte Ltd. All rights reserved 
 

Disclaimer 

The material in this manual is for information purposes only. The contents and the product it 
describes are subject to change without notice. EasyIO Holdings Pte Ltd makes no 
representations or warranties with respect to this manual. In no event shall  EasyIO Holdings Pte Ltd be 
liable for any damages, direct or incidental, arising out of or related to the use of this manual. 
 

EasyIO Holdings Pte Ltd

 

101, Cecil Street #09-07 
Tong Eng Building 
Singapore 069533 
  
 
Worldwide and Asia Pacific Support 

[email protected]

  

Americas Support 

 

 

[email protected]

  

Europe Support   

 

 

[email protected]

  

 

 

Содержание FS Series

Страница 1: ...EasyIO FS32 User Reference v1 4 1 EasyIO FS Series User Reference...

Страница 2: ...EasyIO FS32 User Reference v1 4 2 Document Change Log 12 th March 2019 Remove RS485 built in jumper note FS Series DO NOT have EOL jumper 12 th December 2019 Added IP changing option...

Страница 3: ...mark Notice EasyIO logo are registered trademarks of EasyIO Holdings Pte Ltd BACnet and ASHRAE are registered trademarks of American Society of Heating Refrigerating and Air Conditioning Engineers All...

Страница 4: ...on 5 RS485 Specification 6 Jumpers Setting 7 Wiring diagram 8 Digital Output Wiring Connection 9 Universal Input Connection 10 Universal Output Connection 12 Buttons and Indications 14 Login Details 1...

Страница 5: ...onnection use individual power supply for each controller If a single power supply is used make sure controller power supplies are connected with the same polarity Electrical Power Supply 24V AC 5 or...

Страница 6: ...d keep it as short as possible and never connect more than one device to the wire branch it is not recommended Be careful if single power supply is used for all connected RS485 device make sure all de...

Страница 7: ...EasyIO FS32 User Reference v1 4 7 Jumpers Setting Below image shows the jumper setting for Universal Input Universal Output Watchdog...

Страница 8: ...EasyIO FS32 User Reference v1 4 8 Wiring diagram...

Страница 9: ...tal output is for general purpose isolated digital output connections relay output 24 VAC 2 0A 24 VDC 2 0A Digital Output 8 Channels FS 32 2 Channels FS 20 Type Relay Contacts SPST NO 48VA at 24VAC It...

Страница 10: ...10K 5 Ohm 0 1 5K 1 Ohm Thermistor 10K 10K Shunt 1K Balco 1K Platinum All 0 01 Deg C UI as Digital Input Voltage Free Contact a Resistance The working range of resistance is 500Ohm 500KOhms The commonl...

Страница 11: ...EasyIO FS32 User Reference v1 4 11 Universal Input as Pulse Input specifications Max 20Hz...

Страница 12: ...0 10V mode as it is not design for it and will damaged the UO For current transmitter the circuit able to drive load impedance up to 800 ohm which is ideal for long wire connection up to 500 meter wi...

Страница 13: ...er source it will damage the controller Max DC power source is 24VDC Max load for Universal Output as Digital Output is 200mA Refer below table for software configurations of UO as DO A Digital Output...

Страница 14: ...is pressed whenever manual restart is required The Service button is used to activate the built in boot loader program for software upgrade Each digital output has a correspondence LED to indicate it...

Страница 15: ...rform graphics deployment Username webuser Password 123456 FTP client Firmware Upgrade Login This login allows user to upgrade firmware Username easyio Password 123456 Default IP address 192 168 10 12...

Страница 16: ...S32 via Sedona workbench Locate the object IP under the Service folder Step 2 Click IP object and view properties at the side bar At the newIpAddress newSubnetMask and newGateway property enter your n...

Страница 17: ...1 Login to the FS32 browser Locate the plug in tab and select Network Manager Step 2 At the network manager page configure the new IP address and hit SAVE Controller will reboot and a manual reconnect...

Страница 18: ...ication backup and save a copy into your computer if you have connection to the EasyIO FS Controller Step 2 Cycle power or toggle the reset button Within 5 seconds press and HOLD down the service butt...

Отзывы: