EasyIO FG32 – Installation Guide v2.0 

 

Introduction 

 
EasyIO  FG  Series  is  the  most  powerful  Sedona  controller  in  the  market.  It  is  equipped  with  two  32-bit 
Processors, the first in the Automation industry, with an ARM9 200 MHz Samsung processor (400Mhz for 
FG+ Series), an ARM M3 Cortex for the I/O management and A-D processing, and also with a Linux 2.6 OS 
for premium performance. Later in 2013 we will be adding Graphics capability to serve up html templates 
that  will  be  stored  on  the  Micro  SD  card.  BACnet  and  Modbus  enable.  TCOM  Niagara  integration  is 
available and is encouraged for premium performance with Niagara Framework.

 

 

 

The Build in boot loader enable firmware upgrade to be carried out remotely. No more 
manual service button needed is used. 

 

Firmware upgrading now can be done remotely and without any assistant. 

Document applies to both FG Series and FG+ Series, both 20 points and 32 points hardware. 

 

 

Comparison Chart below shows the difference between EasyIO FG-32 and EasyIO FG-20. 
The  FG+  series  has  a  upgrade  processor  with  400  Mhz  CPU  while  the  FG  series  has  only  200  MHz 
processor.  

 

 

Item

 

 

FG-32

 

 

FG-20

 

 

 

 

 

 

 

 

 

Digital Output

 

 

8 Channels

 

 

2 Channels

 

 

 

Universal Output

 

 

8 Channels

 

 

6 Channels

 

 

 

 

Universal Input

 

 

16 Channels

 

 

12 Channels

 

 

 

 
Table shown above show the different between EasyIO FG-32 and EasyIO FG20in terms of IO point. 

 

 

Содержание FG-32

Страница 1: ...EasyIO FG32 Installation Guide v2 0 1 EasyIO FG Series and FG Series DDC User Reference ...

Страница 2: ...4 th August 2013 Restore Factory settings 10 th Sept 2013 Added in wiring diagram 17 th August 2015 Updated LED indication table 17 th Jan 2018 Updated UO output specification 17 th Dec 2018 Remove Niagara Workbench Sedona files installation as N4 no longer supports Sedona framework Updated disclaimer and support channel emails addresses ...

Страница 3: ...asyIO logo are registered trademarks of EasyIO Holdings Pte Ltd CPT Tool is by Online Tools Inc BACnet and ASHRAE are registered trademarks of American Society of Heating Refrigerating and Air Conditioning Engineers All other product names and services mentioned in this publication that are known to be trademarks registered trademarks or service marks are the property of their respective owners Co...

Страница 4: ... receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equ...

Страница 5: ... 7 Power supply Connection 7 RS485 Connection 8 Jumpers Setting 9 Wiring diagram 10 Digital Output Wiring Connection 11 Universal Input Connection 12 Universal Output Connection 14 Buttons and Indications 16 Login Details 17 Changing IP address 18 Restore factory settings 19 Technical Support 20 ...

Страница 6: ...e and is encouraged for premium performance with Niagara Framework The Build in boot loader enable firmware upgrade to be carried out remotely No more manual service button needed is used Firmware upgrading now can be done remotely and without any assistant Document applies to both FG Series and FG Series both 20 points and 32 points hardware Comparison Chart below shows the difference between Eas...

Страница 7: ...connection use individual power supply for each controller If a single power supply is used make sure controller power supplies are connected with the same polarity Electrical Power Supply 24V AC 5 or 24V DC 20 15 Consumption 750 mA Operating Temperature 32 to 150 Deg F 0 to 65 Deg C Storage Temperature 4 to 150 Deg F 20 to 65 Deg C Operating Humidity 10 to 95 relative humidity non condensing Powe...

Страница 8: ...an be avoided keep it as short as possible and never connect more than one device to the wire branch it is not recommended Be careful if single power supply is used for all connected RS485 device make sure all devices are having the same ground connection Make sure you are connecting the same wire for the same terminal position all H terminals connected to the same wire Physical Interface 1 and EI...

Страница 9: ...EasyIO FG32 Installation Guide v2 0 9 Jumpers Setting Below image shows the jumper setting for Universal Input Universal Output Watchdog and also EIA 485 120 Ohm terminations ...

Страница 10: ...EasyIO FG32 Installation Guide v2 0 10 Wiring diagram ...

Страница 11: ... general purpose isolated digital output connections relay output Pilot Duty rating is as below Pilot Duty 24 VAC 2 0A 24 VDC 2 0A Digital Output 8 Channels FG 32 2 Channels FG 20 Type Relay Contacts SPST NO 48VA at 24VAC It does not output voltage or current It is a dry relay contact Digital Output Connection ...

Страница 12: ...Shunt 1K Balco 1K Platinum All 0 01 Deg C UI as Digital Input Voltage Free Contact a Resistance The working range of resistance is 500 Ohms 500K Ohms The commonly used Thermistor like 10K 10K with Shunt 1K Balco and 1K Platinum are all supported b Voltage Two selection of working range 0 5V and 0 10V The minimum input impedance of voltage input is 1 Mega Ohm c Current Two selection of working rang...

Страница 13: ...EasyIO FG32 Installation Guide v2 0 13 Universal Input as Pulse Input specifications Max 20Hzat 50 cycle ...

Страница 14: ... damaged the UO For current transmitter the circuit able to drive load impedance up to 800 ohm which is ideal for long wire connection up to 500 meter wire length For UO as digital output it can only support up to 24VDC and max load is 200mA each UO channel AC power source is not allowed It will damage the controller Universal Output 8 Channels FG 32 6 Channels FG 20 Type Current 0 20mA 4 20mA max...

Страница 15: ...x load for Universal Output as Digital Output is 200mA each channel Refer below table for software configurations of UO as DO A Digital Output Block must be used EasyIO FG32 FG32 Physical Universal Output Digital Output Block Channel UO1 DO 9 UO2 DO 10 UO3 DO 11 UO4 DO 12 UO5 DO 13 UO6 DO 14 UO7 DO15 UO8 DO 16 EasyIO FG20 FG20 Physical Universal Output Digital Output Block Channel UO1 DO 9 UO2 DO ...

Страница 16: ...d to activate the built in boot loader program for software upgrade Each digital output has a correspondence LED to indicate its current state Image shows the Reset button Service button and also TXRX indicators Image shown is an EasyIO FG 32 unit Image shows the Status indicator Error indicator and individual Digital Output indicator Button and LED indications Image shown is an EasyIO FG 32 unit ...

Страница 17: ...ing on the Communication port TXRX is used to indicate when there are 4 TX2 RX2 Communication activities in Port 2 Transmitting or Receiving on the Communication port Login Details EasyIO FG and FG Series details are as below Sedona Login Username admin Password no password FTP client Webuser Login This login allows user to edit the web files or view CPT graphics deployment files Username webuser ...

Страница 18: ...he object IP under the Service folder Step 2 Click IP object and view properties at the side bar At the newIpAddress newSubnetMask and newGateway property enter your new IP address Inserting invalid values to these properties will brick the network settings A restore factory default is required if controller unable to connect currentDhcp and newDhcp property only supported by FS Series controllers...

Страница 19: ...2 168 10 11 2 Clear the Sedona application in the Sedona VM back to default default app is an empty app 3 Default Sedona apps default login is admin no password Step 1 Make sure you backup the Sedona apps if you have connection to the EasyIO FG32 Step 2 Cycle power or toggle the reset button Within 5 seconds press and HOLD down the service button until the Error LED starts to flash approximately 2...

Страница 20: ...n Guide v2 0 20 Technical Support For technical issue please contact respective region support channel Worldwide and Asia Pacific Support support easyio com Americas Support support easyio pro Europe Support support easyio eu ...

Отзывы: