    Make sure that the ground braid covering the cable is in 

contact with the ground strip when the plug is reassembled. 

Contact between the ground braid and ground strip com

-

pletes the systems ground circuit. See figure 3.

5f.

    Close cover and insert both cover screws. Tighten both 

cover screws until they are snug against their recessed 

plastic surfaces.

Figure 3

HOW TO INSTALL THE CABLE ON THE PIPE

STEP 6  ATTACHING THE CABLE TO THE PIPE

6a.

  Starting at the plug end, either spiral wrap or straight trace the 

cable  on  the  pipe,  as  indicated  in  the  Length  Selection  Chart. 

Mount the plug on the pipe with plastic tie wraps.

Spiral wrapping method

  Spiral wrap the cable around the outside of the pipe. BE SURE to al

-

low the required distance between wraps as indicated in the Length 

Selection Chart. Mark the pipe at the required distance between wraps  

before attaching the cable to the pipe. (See Figure 4).

Straight tracing method

  With the pipe at eye level, run the cable in a straight line parallel 

to and approximately 1/3 of the way from the BOTTOM of the pipe. 

(See Figure 5)

Figure 5

End
Seal 

Valve

Tape

Freeze

d

Free Heating Cable

Figure 4

End

Seal 

Distance between wraps

Freeze

d

Free Heating Cable

Valve

Tape

6b.

  Provide  extra    heat  at  valves  and 

spigots by wrapping each with one 

additional foot of cable, overlapping 

as required.

STEP 7  INSTALLING THE INSULATION

Thermal  insulation  protects  the  Freeze

d

Free  Cable  and  helps  prevent 

pipe freezing.

7a.

  BEFORE insulating, MAKE SURE that there is NO Freeze

d

Free Cable 

damage (such as nicks or cuts) and that the braid is intact.

7b.

  Cover the pipe, cable, connections, valves and spigots with ½" clean, 

dry  fiberglass insulation. DO NOT LEAVE THE CABLE EXPOSED (See 

Figure 6). Where jacket damage is possible, protect the exposed cable 

with insulation or other coverings. Do not cover the Power Indicator 

Light with insulation or covering.

•  ONLY  use  fire-resistant  insulation  materials  such  as  fiberglass 

wrap.

•  MAKE  SURE fiberglass insulation is water-proof by installing a 

water-tight sleeve or vapor barrier such as polyethylene sheeting 

around it whenever there is ANY chance that it might come in 

contact with water. 

7c.

  Place  the  “Caution”  label  on  the  insulation-covered  

pipe where it can be easily seen. 

Figure 6

6c.

  Fasten  the  cable  to  the  pipe  at 

SIX-INCH  intervals  with  tape.  If 

excess  cable  remains  at  the  end 

of the pipe,  Double  it  back along 

the  pipe  where  the  insulation  will 

COMPLETELY cover it. Be sure cable 

is held tightly to the pipe.

6d.

  Tape end seal to pipe.

6e.

  In  a  mobile  crock  or  standpipe, 

NEVER  install  the  Freeze

d

Free 

Cable  end  seal  where  it  would 

normally be submerged.

End Seal

Crock

Pipe

Ground

  Level

HOW  TO  OPERATE  AND  MAINTAIN  YOUR 

FREEZE

d

FREE CABLE SYSTEM

STEP 8  PUTTING YOUR FREEZE

d

FREE SYSTEM 

 

TO WORK

Once installation is complete, plug the cable into a 120 volt AC outlet. 

Do not use any water for about an hour and then turn on a water tap 

on the Freeze

d

Free protected pipe and test the temperature of the water.  

It  should    feel  warm  almost  immediately  as  the  water  heated  by  the 

Freeze

d

Free Cable runs through the pipe.

STEP 9  TROUBLESHOOTING

I f   i n   S t e p   8 ,   t h e   w a t e r   d o e s n ’ t   f e e l   w a r m   w h e n   t h e 

tap  is  turned  on,  or  any  time  a  freeze-up  on  the  Freeze

d

Free  

protected pipe occurs visually check the power light on the plug to see if 

the cable is energized. If the power light is off, unplug the Freeze

d

Free 

Cable, and check for and correct the  following:
9a.  Do you have power going to your electrical outlet?
9b.  Is the fused plug wired correctly?
9c.  Is fiberglass insulation applied properly dry?
9d.  Have you installed the correct amount of cable for your pipe diameter, 

lowest expected temperature, and insulation thickness?

 

WARNING

 

If  ANY  PART  of  the  Freeze

d

Free  Cable  System  is   

damaged,  the  WHOLE  SYSTEM  is  damaged.  NEVER  

attempt  to  repair  ANY  PART  of  the  cable  system,  

including  a  blown  fused  plug.  ALWAYS  replace  a  

damaged system with a NEW system.

a

STEP 10 SEASONAL INSPECTION

While the Freeze

d

Free system can be left plugged in all year, you will 

save energy if you unplug it during non-freezing weather. In any case, 

EACH TIME you plug it in,  OR AT LEAST once a year if you leave the 

system plugged in, or ANY time you have reason to suspect damage, 

make  the  following inspection:

10a.

 C h e c k   t h e   E N T I R E   F r e e z e

d

F r e e   s y s t e m   f o r 

signs  of  damage.  NOTE  this  may  be  evidenced  by  damaged  or 

discolored insulation.

10b.

 I n s p e c t   A N Y   e x p o s e d   p o r t i o n   o f   t h e   c a b l e   f o r  

evidence of cuts, nicks, abrasions, gnawing by animals, or other 

physical damage.

10c.

 I f   t h e r e   i s   d a m a g e ,   I M M E D I AT E LY   R E P L A C E   t h e  

damaged cable system.

10d.

 After  a THOROUGH  INSPECTION, repeat Steps 8 and 9.

Содержание FREEZE FREE

Страница 1: ...the system is connected the risk of fire is increased ALWAYS use a ground fault protection device GFPD to reduce the danger of fire from a damaged or im p r o p e r l y i n s t a l l e d h e a t i n g...

Страница 2: ...Lowest Expected Temperature Dia 20 F 7 C 0 F 18 C 20 F 29 C 40 F 40 C 60 F 51 C 1 2 1 1 1 5 2 2 4 str str 23 8 11 2 11 4 3 4 1 1 1 1 7 2 3 2 9 str 71 4 23 8 11 2 11 4 1 1 1 3 2 2 7 3 3 str 5 23 8 15 8...

Страница 3: ...seen Figure 6 6c Fasten the cable to the pipe at SIX INCH intervals with tape If excess cable remains at the end of the pipe Double it back along the pipe where the insulation will COMPLETELY cover it...

Страница 4: ...by written agreement Any implied warranty of merchantability or fitness for particular purpose that may arise in connection with the sale of this product shall be limited in duration to twelve 12 mont...

Страница 5: ...w one Reemplace SIEMPRE las cubiertas resistentes al agua y los aislantes da ados luego de CADA inspecci n del cable Conecte el enchufe UNICAMENTE a un tomacorriente instalado seg n el C digo El ctric...

Страница 6: ...1 1 3 1 7 str str str 31 8 2 3 4 1 1 1 1 1 5 2 str str 71 4 3 2 1 1 1 1 3 1 8 2 4 str 5 5 23 4 17 8 11 4 1 1 1 1 6 2 1 2 9 str 111 2 4 1 4 27 8 17 8 11 2 1 1 2 1 8 2 4 3 2 str 9 4 23 4 17 8 2 1 1 5 2...

Страница 7: ...pueda verse con facilidad Si desea m s etiquetas llame gratis al 800 562 6587 Figura 6 6 c Sujete el cable en la tuber a colocando cinta a intervalos de SEIS PULGADAS Si sobra cable en el extremo de...

Страница 8: ...r medio de un contrato escrito Cualquier garant a impl cita de calidad e idoneidad para un fin determinado que pueda surgir en relaci n con la venta de este producto se limitar a la duraci n de doce 1...

Отзывы: