background image

 

www.easyfix.com 

Persse Business Park, Ballinasloe, Co. Galway. H53 VK10. 

CIM V8 22 

 

 

 

 

 

Installation Manual 

 

 

 

 

Cubicle / Freestall

 

 

Содержание Cubicle

Страница 1: ...www easyfix com Persse Business Park Ballinasloe Co Galway H53 VK10 CIM V8 22 Installation Manual Cubicle Freestall ...

Страница 2: ...f power tools when screwing the fixings If drilling is required ensure there are no water pipes where you intend to drill Dispose of packaging carefully and responsibly Helpful Hints Assemble the parts in the correct order as outlined in this manual first then fix after all parts are assembled If multiple cubicles are being assembled carry out Step 1 for all of the cubicles then Step 2 for all of ...

Страница 3: ...ight Angle Calm 1 Post 2 Clamp 3 Top Pipe Calm Siesta Dream Flex Rigid 4 Bottom Pipe 5 Coupling 6 Neckrail 7 Scratcher 8 Loop 9 Direct Steel End Wall Bracket 10 Extended Steel End Wall Bracket Other versions of wall connectors may or may not be applicable to your order ...

Страница 4: ... Through Bolt B M10x100mm Bolt C M10 Lock Nut D Tec Screw E M8 x 75mm Screw F M8 Rivet Nut G 25mm Washer H M6 x 40mm I M12 Lock Nut J 50mm SS Screw K Plastic Plug L 80mm SS Screw M M12x40mm Bolt May or may not be applicable to your order ...

Страница 5: ...m clamp for the Dream and Siesta models is the same but for the purpose of the manual they will be labelled separately just to account for the different top and bottom clamps in the Calm model Refer to Page Z for more detail on the clamp styles for each model The positioning measurements in the appendices are applicable to the Set in Concrete Bolt To Floor and Wall Mounted configurations but for i...

Страница 6: ...for full positioning guidelines for the Single and Double post cubicles EASYFIX recommends a cubicle bed slope of 3 4 Step 1 1 Set in Concrete Single Bed Step 1 2 Bolt to Floor Single Bed Parts List Item ID Part Name Qty 1 Post 1 A M12 Through Bolt 4 M12 Through Bolt Pilot Hole Ø12mmx100mm deep 1260mm ...

Страница 7: ...the double sided clamp push the M12 bolts through both clamps and secure with a nut Do not tighten the bolts fully only lightly to keep the sub assembly together Parts List Item ID Part Name Qty 2 Clamp matching halves 1 M M12x40mm Bolt 4 I Locknut M12 4 Step 3 Slide on the Clamps Slide the pre assembled clamps over the post If angled clamps are used in your cubicle Calm model only lower the angle...

Страница 8: ...C provided Parts List Item ID Part Name Qty B Bolt M10x100mm 1 C Locknut M10 1 Step 5 Securing the Pipes and Clamps Ensure that the clamps are at the appropriate heights See Appendix A B for EASYFIX recommended measurements Tighten the pipe bolts securing both the pipes and clamps in place Step 6 Placing the Couplings Slide a coupling along each of the top pipes Ensure the coupling is put on in th...

Страница 9: ...ail and insert it in the next coupling Slide the scratcher along the neckrail until it sits in the middle of the bed This will be later fixed Step 8 Attaching the Loops Insert the rubber loop to the appropriate pipe ensuring that the top side is inserted into the top pipe The orientation of the loop is printed at the end of the loop Press fit the rubber loop in until the pipe is flush with the ins...

Страница 10: ... key measurement is the distance from the neckrail to the heelstone as can be seen in Appendix A and Appendix B This measurement should sit between 2058mm 6 9 and 2108mm 6 11 Fixing The Fixing ID identifies which bag the fixing belongs to in accordance with the bag identifier on the bag labels It is advised to use the fixing for the application from the Fixing ID given in the instructions These I ...

Страница 11: ...p to Pipe Top Bottom B Coupling to Pipe Neckrail C Scratcher to Neckrail D Pipe to Stem Top Bottom Note All bolts fixings should be rechecked retightened where necessary after the first 3 months of use and once yearly thereafter ...

Страница 12: ...11 End Wall Bracket Installation Direct End Wall Bracket Extended End Wall Bracket Note For use where the neckrail runs above the height of the end wall ...

Страница 13: ...2286mm 2438mm 7 6 8 0 Use 1 8m 5 11 long pipes For Cubicle bed lengths Y of 2438mm 2743mm 8 0 9 0 Use 2m 6 7 long pipes For Cubicle bed lengths Y greater than 2473mm 9 0 Use 2 2m 7 3 long pipes The 940mm centre to centre measurement between the cubicle clamps is recommended This can be adjusted for smaller animals ...

Страница 14: ...82mm 16 17 Use 2m 6 7 long pipes For Cubicle bed lengths Y of 5182mm 5486mm 17 18 Use 2 2m 7 3 long pipes Note For bed lengths Y in excess of these guidelines it is recommended to use two single posts back to back to achieve the correct cubicle loop to heelstone measurement Z The 940mm centre to centre measurement between the cubicle clamps is recommended This can be adjusted for smaller animals ...

Страница 15: ...14 Appendix C Dream Top Pipe Top Clamp Bottom Pipe Bottom Clamp Calm Top Pipe Top Clamp Bottom Pipe Bottom Clamp Siesta Top Pipe Top Clamp Bottom Pipe Bottom Clamp ...

Отзывы: