9
UNPACKING/ASSEMBLY/OPERATION
Please read this manual and follow the directions before using the equipment.
The carton contains:
1.
Instruction manual
2.
EB-9000PS power supply
3.
EBSHH-1 Soldering handpiece holder, including Brass curls and sponge
4.
EBSHP-1 Soldering handpiece, with green and gray grips,
5.
EBRMP-1 Tip removal pad
6.
EBM8CH176 Soldering Cartridge
Important: Keep all shipping materials until satisfactory operation has been verified.
Assembly and Operation
1.
Remove EB-9000PS power supply base from its box and place on a
suitable work bench equipped with AC power.
2.
Remove the EBSHH-1 work stand from its box. The unit should include a
brass tip cleaning curl and a rectangular sulphide free sponge.
3.
Remove the EBSHP-1 handpiece from its box and place into iron holder.
4.
Plug the handpiece cord into one of the front connectors and ensure that
the slide switch is positioned towards the plugged handpiece.
5.
Plug tip cartridge into handpiece
6.
Moisten the sponge with DE-Ionized water.
7.
Connect the AC plug to a suitable AC power outlet.
8.
Switch the power switch to the “on” position.
9.
Allow a few seconds for tip cartridge to reach soldering temperature.
10. The unit should be ready to use.
Temperature Calibration
Easy Braid “Curie Heat Technology” systems do not require temperature
calibration. The technology is very precise and is self regulating. The alloy used
in the construction of the tip cartridge will maintain the set temperature for its
entire life.