very apartment must have a unique identification called the User Code (address). 

DIP switches are used to configure the User Code for each Monitor.

Bit-1 to Bit-5 are used to

 set the User Code. The values are from 1 to 32, giving 32 different 

codes for 32 apartments.

 

   

When  multiple  monitors(4 max)  are  installed  in  one  apartment,  these  monitors  have  to  use 

the  same  User  Code  setting and  the  Master/Slave  mode  should  be  set  on  the Monitor.  
Bit-6 is line termination switch (EOL), this has to be set to ON if the Monitor is at the end of 
the line(bus), otherwise set to OFF. 

11.8 User Code Setup

            Flashes slowly (enabled)

11.7 How to enable/disable auto unlocking (Disabled by default). 

Function Description:
Auto unlocking 

allows the door to unlock after 5 seconds of a placed call from the door 

station without the need to answer or unlock the door, this allows the user to 'leave the 
door on the latch' for a known visitor. 

To Enable this function; from the installation page enter the following:

9018 is used to Enable the function - 'AU FUNC ON' will show on screen.
9017 is used to Disable the function - 'AU FUNC OFF' will show on screen.

Содержание CDV43

Страница 1: ...2 Wire Video Intercom System CDV43 USER MANUAL EN Read this manual carefully before using the product keep in a safe place for future use ...

Страница 2: ... GND NC 3 ON L1 L2 DIP 4 5 6 1 2 SW SW RING GND NC 3 ON L1 L2 DIP 4 5 6 SW SW Door bell call button connection port Ring GND Extra buzzer connection port NC Reserved L1 L2 2 wire Bus terminal DIP switches Total 6 bits can be configured Bit1 Bit5 Used to set User Code Bit6 Set to ON when the monitor is at the end of the line EOL or operates with a DBC4A otherwise set to OFF 2 Monitor Mounting 1 Par...

Страница 3: ...ess CALL button on the outdoor station the Monitor rings and the screen will display the visitors image Press Menu Close button in standby mode the main menu page will be shown as follows 1 Use the screws provided to fix the Mounting Bracket fits a standard UK single gang flush back box if required Fitting accessories includes a Bracket Two x M4 x 25mm screws are needed for fastening the Mounting ...

Страница 4: ...ll conversation is started and the other monitors will stop ringing 3 Call Guard Unit A Monitor can be assigned as Guard Unit Monitor when the Guard Unit Monitor answers the call conversation with the guard person is started When the monitor is in standby mode press Menu button to enter main menu page Use button to move up down to select Intercom Call press Menu button to enter the Select Intercom...

Страница 5: ...to confirm 6 Divert Call Function Requires CDV GSM 7 Do Not Disturb Function When the monitor is in standby mode press Menu Button to enter main menu page Use button to move up down to select Don t Disturb press Menu button or press Mute button indicator directly to enter the No Disturb page there are 4 options 1 No Divert calls from outdoor station will not be diverted 2 If No Answer Calls from o...

Страница 6: ...is in standby mode press Menu Button to enter main menu page Use Button to move upward downward to select Light option press Menu Button to enter the Light Option page there are 3 options 1 Turn On Select it to open the staircase light the light will be turned off automatically after 60 seconds 2 Turn On 5min Select it to open the staircase light the light will be turned off automatically after 5m...

Страница 7: ...nu button to confirm Press Unlock button and hold for 3secs Use button to increase decrease the value required and press Menu button to confirm 11 1 How to enter the installation setting page A Monitor can be assigned as Guard Unit Monitor when the Guard Unit Monitor answers the call conversation with the guard person is started The code number of 8004 is used to set the monitor as a guard unit mo...

Страница 8: ...artment one master monitor together with 3 slave monitors addresses must be the same note must have one monitor to be set as master monitor Code 8000 is used to set the master monitor Code 8001 is used to set the first slave monitor Code 8002 is used to set the second slave monitor Code 8003 is used to set the third slave monitor In default mode when receive a call the master and slave monitors wi...

Страница 9: ...termination switch EOL this has to be set to ON if the Monitor is at the end of the line bus otherwise set to OFF 11 8 User Code Setup Flashes slowly enabled 11 7 How to enable disable auto unlocking Disabled by default Function Description Auto unlocking allows the door to unlock after 5 seconds of a placed call from the door station without the need to answer or unlock the door this allows the u...

Страница 10: ... 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 ...

Страница 11: ...all press Menu button the Adjustment menu will be displayed Use the Menu to select the option required use button to increase decrease the value press the Return button to quit the adjust page 1 A total of 4 screen modes can be selected in 3 The Volume options are for ring tone and talking volume adjustment door station BUS IM BUS DS PC6 AC Doorbell Button 1 2 NC GND RING sw sw 3 ON L1 L2 DIP 4 5 ...

Страница 12: ...D4 V1 14 Specifications Power supply for indoor monitor DC 20 28V Power consumption Standby 0 17W Working status 4 7W Monitor screen 4 3 inch digital color TFT Display Resolutions 480 R G B x 272 pixels Video signal 1Vp p 75Ω CCIR standard Wiring 2 wires non polarity Monitor time 40 seconds Talking time 90 seconds Dimensions 137 H 137 W 17 D mm ...

Отзывы: