C1 Programming transmitters/buttons
If a previously programmed transmitter/button is
programmed again in the same output, the previ-
ous operating mode is overwritten with the new
operating mode.
32 transmission codes can be programmed per
output.
External buttons are programmed just like radio
transmitters and should be used in 1-button op-
eration (1TB).
If the external buttons have not been programmed
in another operating mode, they operate in the
ON/OFF operating mode ( ) with 1-button op-
eration.
Operation
1)
[Press button]
Indication
Note
Programming 2TB
P
1x briefly
LED 2TB flashes
Programming mode 2-button operation
started.
M
repeatedly Number for the OM in
the digital display
Select operating mode (OM).
CH1/CH2
LED
CH1/CH2
and
LED 2TB flash
Select output.
Only one output can be active at a time;
change as often as required.
Transmitter
button
Tx
or
button
1x briefly
LED 2TB and
LED of the selected
output light up
Transmission code/button code programmed.
When all the LEDs turn off, the receiver is
ready for operation.
Programming 1TB
P
2x briefly
LED 1TB flashes
Programming mode 1-button operation
started.
M
repeatedly Number for the OM in
the digital display
Select operating mode (OM).
CH1/CH2
LED
CH1/CH2
and
LED 1TB flash
Select output.
Only one output can be active at a time;
change as often as required.
Transmitter
button
Tx
or
button
1x briefly
LED 1TB and LED
of the selected output
light up
Transmitter/button programmed.
When all the LEDs turn off, the receiver is
ready for operation.
C Programming
C2
Adjust TIMER
The switching times for operating modes 4 and
5 can be set individually for each output.
The switching time is calculated using the base
time measured during programming and the se-
lected multiplier.
The maximum base time is 60 seconds. After this
time, the measurement stops automatically and
skips to the multiplier selection.
TIMER individual ( )
The set switching time applies individually to eve-
ry transmitter/button programmed to this operat-
ing mode.
The most recently set switching time is saved and
used during programming.
The switching time assigned to a transmitter/but-
ton can only be changed by programming the
transmitter/button again.
TIMER global
( )
The set switching time applies globally to all
transmitters/buttons programmed to an output.
The most recently set switching time set is also
used for transmitters/buttons that have already
been programmed.
Operation
[Press button]
Indication
Note
1.
P
1x briefly
LED 2TB flashes
Programming mode started
2.
M
repeatedly
Number of the OM in
the display
Select the timer mode to be adjust. ( or )
3.
CH1/CH2
LED
CH1/CH2
and
LED 2TB flash
Select output.
Only one output can be selected.
4.
P
> 1.6 s
LED 2TB + 1TB
flash alternately
Display: Seconds
count up
The measurement of the base time for the
timer is started.
In the display, the seconds count up from
1-10 (0) a maximum of 6 times.
After a maximum of 60 s, the measurement is
stopped automatically.
5.
P
1x briefly
2TB+1TB light up
Display: Multiplier (A)
flashes
The measurement of the base time is
stopped. The currently selected multiplier is
shown in the display.
6.
M
repeatedly
2TB + 1TB light up
Display: current
multiplier flashes
Set the multiplier to be used for the time just
measured (see section B4, "Timer multiplier
table").
7.
P
1x briefly
2TB+1TB light up
Display: multiplier
selected lights up
The measured time is multiplied by the
selected multiplier and saved as the new
switching time.
When all the LEDs turn off, the receiver is
ready for operation.
Programming can be cancelled by pressing the
P
button several times.
The order is: 2TB
→
1TB
→
Operating mode. In operating mode, all red LEDs and the display are
off, as long as no output is activated.
5
1) Timeout: If no buttons are pressed within 30 seconds, the RCU08 automatically switches back to
operating mode. The settings are not saved.
1TB
P
M
CH1 CH2
2TB
PWR
Tx
P
M
CH1/CH2
<
1,6 s
<
1,6 s