TERMINATION CAPS (CONT.) 

 
When venting with a manufactured vent system, vent termination caps must be of a 
design that prevents direct wind infiltration into the venting system. If wind is permitted 
to infiltrate into the venting system, static pressure may build and trip the appliance 
blocked flue sensor, resulting in nuisance appliance shutdowns.  
 
 

GENERAL EXHAUST VENT INSTALLATION REQUIREMENTS 

-  All vent pipe used with a slip fit connection must be mechanically secured by 

means of 3 stainless sheet metal steel screws at 120 degree intervals. 

-  All vent pipe used that does not have a manufactured gasket/sealing 

mechanism must be sealed with a suitably rated high temperature RTV type 
silicone at all joints, in addition to sealing any screw penetrations.  

-  If a seam is present in a single wall duct material, orient the seam to the top 

side of the duct, and apply high temperature RTV silicone and/or suitable 
metal tape as required to ensure that the seam is gas tight. 

-  All venting used must be adequately supported to prevent sagging. 
-  When the vent pipe passes through a cold or unheated area where the 

ambient temperature is likely to produce condensation of the flue gases, the 
vent pipe must be insulated with a suitable insulation material that is 
approved and specified by the insulation manufacturer to withstand 
temperatures up to 450 F (232 C). 

-  Blockages of air intake and exhaust vent caps by snow and/or ice must be 

prevented. 

-  A maximum of 3 90 degree elbows may be installed in any vertical exhaust 

vent system. 

-  Maintain a downward slope on the venting material of no more than 1/4” per 

foot (6.3 mm) from the start of the vent system to the vent terminal. Do not 
apply downward slope to the appliance itself, it must be installed to be 
horizontally level.  

 

COMMON EXHAUST VENTING OF APPLIANCES 

A single EZM series unit may be exhausted on a common 6” vent with the use of the 
factory supplied AC1120 4”x 4”x 6” (10 x 10 x 15 cm) exhaust T, for both side wall and 
roof venting. A suitably rated and certified high temperature exhaust cap must be used 
on the end of the 6” exhaust vent.  
 
The addition of the AC1120 exhaust T incorporates a 90’ degree bend into the venting 
of each side of the unit, deducting 10’ (1.5 m) from the allowable total of exhaust/intake 
venting for each commonly vented unit. 

 
 
 
 
 
 
 
 
 

Содержание Middleman EZM-90-40

Страница 1: ...the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 The latest edition Electrical Code PART 1 CSA C22 1 in Canada and ANSI NFPA NO 70 in the USA...

Страница 2: ...light this or any other appliance 6 Ne pas tenter d allumer ceci ou aucun autre appareil WARNING This appliance may have sharp edges and corners Wear protective clothing such as gloves and protective...

Страница 3: ...used for the storage of combustible materials signs must be posted to specify the maximum permissible stacking height to maintain the required clearances from the heater to the combustibles and that s...

Страница 4: ...ervicing Minimum distance from the radiant surface to the floor in non agricultural installations is 7 ft 2 1 m in Canada and 8 ft 2 4 m U S A Minimum clearances inches and cm from combustibles are me...

Страница 5: ...t 90 000 2 x 45 000 EZUM 90 25 27 3 50 ft 90 000 2 x 45 000 EZUM 100 25 27 3 50 ft 100 000 2 x 50 000 4 13 15 31 EZUM 100 30 32 3 60 ft 100 000 2 x 50 000 EZUM 120 30 32 3 60 ft 120 000 2 x 60 000 Mod...

Страница 6: ...6 CONTROL BOX AND BURNER HOUSING DIMENSIONS EZM EZUM...

Страница 7: ...nditions that may be encountered Installation must conform with all local building codes or in the absence of local codes to the National Fuel Gas Code ANSI Z223 1 NFPA54 in the U S A or the Natural G...

Страница 8: ...ating equipment WARNING HEATER EXPANSION It is a normal condition that during heat up and cool down a tube heater will expand and contract Allowances for heater expansion must be made in the gas conne...

Страница 9: ...sity radiant tube heaters are suitable for use in aircraft hangars when installed in accordance with the latest edition of the Standard for Aircraft Hangars ANSI NFPA No 409 in the USA or the Canadian...

Страница 10: ...s Celsius It is the installer s responsibility to ensure that building materials with a low heat tolerance which may degrade at lower temperatures are protected to prevent degradation Refer to Clearan...

Страница 11: ...tion of the appliance The first hanger must be no more than 6 inches from the burner flange For straight unit hangers suspend from the top ring on the hanger if the reflectors are to be horizontal and...

Страница 12: ...length Reflectors can now be placed in the hangers To prevent walking of the reflectors the first and second reflector can be joined together at the overlap with a sheet metal screw Do not attach more...

Страница 13: ...13 TABLE 3 HANGER SPACINGS...

Страница 14: ...ength as much as inch 12 7 or more for every 10 ft 3 m of system length Typically the greater the firing rate the greater the expansion Survey the available structural supports considering the system...

Страница 15: ...here the receptacle is switched by the thermostat controller Heating zones may be established where one 120 Volt thermostat controls more than one heater provided the total heater electrical load does...

Страница 16: ...urner to gas supply with flexible gas connector 3 A drip leg must be installed in the gas line at the heater inlet connection tee followed by a pipe drop to the heater Failure to provide a drip leg co...

Страница 17: ...e Hose and Hose Couplings for Conducting Propane and Natural Gas CSA 8 1 and of a length of 36 6 in 91 15 cm with an ID of a least in 12 7 mm In USA an approved Stainless Steel Flexible Gas Connector...

Страница 18: ...rm to local codes Provide a 1 8 in 3 2 mm NPT plugged tapping accessible for test gauge connection immediately upstream of the gas supply connection to the heater Test for leaks All gas piping and con...

Страница 19: ...ate In cases where a manufactured venting system s certified installation instructions contravene this manual e g vent lengths vent clearances number of elbows transitions required terminations etc de...

Страница 20: ...s with inputs over 100 000 BTUH Within 36 in 91 5 cm of a window or door that can be opened in any building any non mechanical air supply inlet to any building or of the combustion air inlet of any ot...

Страница 21: ...nt pipe passes through a cold or unheated area where the ambient temperature is likely to produce condensation of the flue gases the vent pipe must be insulated with a suitable insulation material tha...

Страница 22: ...at least 4ft3 min 1000Btuh 0 38m3 min kW input of installed heaters Some local codes may require an electrical interlock to a dedicated exhaust fan Exhaust must be located as high as practicable in th...

Страница 23: ...orizontally or vertically and must be protected with a suitable screened cap to prevent pest debris infiltration of the duct Do not use termination caps that utilize a damper or flapper system See acc...

Страница 24: ...24...

Страница 25: ...dia AC1100 Outside Air Wall Cap 4 10 cm dia AC1110 Combustion Air Flex Duct 4 10 cm dia AC1111 Combustion Air Duct 4 10 cm dia AC1120 4 x 4 x 6 Tee AC1130 90 degree Elbow 4 10 cm dia AC1140 AC1145 18...

Страница 26: ...26 EASY RADIANT WORKS ACCESSORIES NOTE FOR EXPANDED 4 ID END ORDER PART AC1190...

Страница 27: ...27...

Страница 28: ...28...

Страница 29: ...s dommagnes mat riels de blessure ou la mort Le service d entretien qualifi e est responsible de l installation de crette trousse L installation n est pas ad quate no compl te tant que le bon fonction...

Страница 30: ...iated valve with pictorial illustrations 4 A rating label indicating model no serial no btu hr rating orifice size and identification of the gas to which the appliance is to be converted The conversio...

Страница 31: ...d pressure regulator cap screw Refer to chart below for manifold pressure and maximum and minimum gas pressures of the converted heater Gas Supply Natural Gas Propane Manifold Pressure 3 5 W C 10 0 W...

Страница 32: ...ion occurs then the control itself is suspect and should be changed If the igniter operates and there is still no ignition then the gas valve is suspect Be sure that the main gas supply is on that the...

Страница 33: ...l distributor or the manufacturer WARRANTY ALL Easy Radiant Works heaters are covered by a 4 year guarantee All heaters manufactured by Easy Radiant Works are warranted to the original user against de...

Страница 34: ...r START UP TECHNICAL SUPPORT INFORMATION This equipment has been factory fired and tested prior to shipment To ensure that site conditions are compatible with the heater s performance the following st...

Страница 35: ...INLET GAS SUPPLY PRESSURE WITH HEATER OPERATING WC GAS VALVE OUTLET Manifold PRESSURE WITH HEATER OPERATING WC WHAT IS THE LINE VOLTAGE READING AT THE HEATER VOLTS WHAT IS THE VOLTAGE READING AT THE I...

Страница 36: ...36 AB2017 H S I CONTROL MODULE...

Страница 37: ...ller ONLY 7 wire C2 PIN 9 Black Igniter PIN 10 Orange Flame sensor IMPORTANT 10 and 12 Loop together for units with single flame sensor For EZM dual flame sense 10 and 12 lead to individual flame sens...

Страница 38: ...operly earth grounded 5 Flame sense rod contaminated or in incorrect position 6 HSI element located in incorrect position 7 Hot surface element or flame sense rod wiring in good condition and properly...

Страница 39: ...39 DH21040D_B WIRING DIAGRAM DISCONTINUED...

Страница 40: ...40 S89H WIRING DIAGRAM DISCONTINUED...

Отзывы: