Easy-Kleen MAGNUM 4000 Скачать руководство пользователя страница 8

** Hot Water Pressure Washers Only 

Eectrically Operated Burners – Some  models  generate  12V from the  gasoline  engine 
and  provide  the  necessary power for  the burner. Others utilize  a 120v connection  which 
must  be grounded. IF  YOU REQUIRE UPGRADES  OR  MODIFICATIONS  TO 
YOUR  EXISTING ELECTRICAL SYSTEM  IN ORDER  TO OPERATE YOUR 
PRESSURE WASHER,  THEY  MUST  BE PERFORMED BY A LICENSED 
ELECTRICIAN AND BE COMPLETED IN ACCORDANCE  TO  ALL  APPLICABLE 
CODES  IN YOUR  AREA  OF  OPERATION. The power supply must be adequate for 
your specific unit. Make sure to verify the data plate for your machine’s specific 
requirements (i.e. voltage, amperage, etc).  

WARNING: 

All electrically powered units  must be provided with suitable  overload and 

overcurrent protection in accordance with the Canadian  Electrical Code part 1. 

Confirm the GFCI (Ground Fault Circuit Interrupter) is in good working order. 

6. Pressure adjustment - The  pressure regulator  (unloader)  is located  on  the pump (see

diagram).  It  controls the  pressure being  generated by the  pressure  washer. This
regulator may  be adjusted to the  desired  pressure by turning the adjustment knob.
Turning the adjustment knob  clockwise will increase the  pressure. NEVER  OPERATE
SYSTEM  AT A  HIGHER  P S I THAN  THE  MAXIMUM  RATING.   This machine  has
been  adjusted to operate  at  a  specific maximum pressure  as per  the  machine
specifications.  Pressure may  be reduced  for lighter  use by turning the  Pressure
Regulator/Unloader counter clockwise.

7. You are now ready to start the cleaning operation  - Pull  trigger  on the  pressure wand

assembly  to start cleaning. To stop  the  pressurized water,  release the  trigger.  DO NOT
LEAVE UNIT  RUNNING  WHEN  NOT  IN USE.

8. **To stop  Burner operation – Turn  the  b u r n e r   control  switch  to off (or PUMP for

electric machines) and  run pump for  two minutes with the trigger gun pulled  to allow
the coil to cool down. After the cooling period is complete, turn  off main
power to engine/motor. Squeeze and release  the trigger for  the  second  time  in order to
relieve the  pump  system  of pressure.

9. Prior  to storage  – Inspect  the  pressure  washer  for  any  damage  or required

maintenance. If your machine needs to be exposed to cold weather, please refer to the
winterization instructions found in this manual.  If  possible, do not allow unit to remain
outside in the elements.

10.Warning – If unit  is left running  while not  in use, pump  damage  may occur. Do

not  leave unit  running while not  in use!

11.Battery Specifications for electric start systems only – Rating:  165CCA,

190 CA or better, dimensions: 8” x 5” x 6”.

Содержание MAGNUM 4000

Страница 1: ...MAGNUM 4000 SERIES OWNER S MANUAL Call 1 800 315 5533 Email sales easyleen com ULTRA GOLD PLUS 3600 NEW 2014...

Страница 2: ...ttempting to assemble install operate or service this pressure washer Failure to comply with the instructions could result in personal injury and or property damage CONTENTS Safety Information Introdu...

Страница 3: ...NT THIS EQUIPMENT IS TO BE USED ONLY BY TRAINED OPERATORS AND MUST ALWAYS BE ATTENDED DURING OPERATION WARNING To reduce the risk of injury read operating instructions carefully before using Read the...

Страница 4: ...WARNING Keep water spray away from electrical wiring All electrically powered equipment must be grounded at all times to prevent fatal electric shots Do not spray water on or near electrical component...

Страница 5: ...ck Hold with both hands Hold firmly to the gun and wand during start up and operation of the machine Do not attempt to make adjustments while the trigger gun is in operation WARNING Risk of injury fro...

Страница 6: ...EL Refer to the engine operation manual included with your pressure washing unit Gas Engine Oil level The engine is a 4 cycle and uses 10W30 detergent oil Refer to Glossary or engine manual Oil Fired...

Страница 7: ...to PUMP adjust the burner thermostat to desired temperature turn switch to BURNER 5 Burner operation Be sure water is flowing through water heater coil before turning on burner switch Turn thermostat...

Страница 8: ...se the pressure NEVER OPERATE SYSTEM AT A HIGHER P S I THAN THE MAXIMUM RATING This machine has been adjusted to operate at a specific maximum pressure as per the machine specifications Pressure may b...

Страница 9: ...he chemical injector at the pump into the chemical being used 3 Turn the adjustment knob on the wand or lance to the open position OR when single lance is used black nozzle will need to be used on wan...

Страница 10: ...e on to the female inlet on the pump 2 Place the open end of the hose into a wide mouthed container of full strength winter rated vehicle windshield washing fluid or Anti Freeze RATED FOR MINIMUM 40 C...

Страница 11: ...omponents Damage from freezing is not a warrantable item Water Condition Use a softener on your water system if local water is known to be high in mineral content The advantages of soft water are very...

Страница 12: ...0 W Non Detergent for GP Pumps and Hydraulic 68 for EK Pumps 2 Change all other components on the pump as needed GASOLINE ENGINE DAILY 1 Check oil for proper level and adjust accordingly 2 Examine the...

Страница 13: ...n the pump see diagram OIL GASOLINE ENGINE Machines which are powered by gasoline engines need appropriate lubricant Use 10W30 detergent oil BURNER The burner heats the water in hot water pressure was...

Страница 14: ...ur l Eau Chemical Injector Injecteur de Produits Chimique Hot Water Outlet Sortie d Eau Chaude Unloader R gulateur Pression 13 Pneumatic Tires Pneus 13 High Pressure Connector Hose Tuyau Connecteur Ha...

Страница 15: ...der R gulateur Pression Hot Water Outlet Sortie d Eau Chaude Water Inlet Entr e pour l Eau EK Pump Pompe EK High Pressure Connector Hose Tuyau Connecteur Haute Pression Pressure Relief Valve Valve de...

Страница 16: ...Poign e D pliante General Pump Also Available GP Pompe General Pump Aussi Disponible GP Type of Oil needed for Pumps EK Pump Hydraulic 68 650ml GP Pump SAE 30 Non Detergent Type d Huile pour les Pomp...

Страница 17: ...properly or damaged Make sure you have the right nozzle size Check the pressure of the pump with a pressure guage and adjust to desired pressure If you cannot reduce the pressure replace the unloader...

Страница 18: ...ough the swtich consult a professional for this if you do not know how to do this properly as you can get severly injured by the electrical current connected to your machine If current properly flows...

Отзывы: