** Hot Water Pressure Washers Only
WINTER PUMP/COIL PROTECTION
The following procedure MUST be used when the pressure washing
unit is stored at temperatures below freezing.
1. All water must be drained or blown (via compressed air) from system.
Connect a short piece of male fitted ½” garden type hose on to the
female inlet on the pump.
2. Place the open end of the hose into a wide mouthed container of full
strength, winter rated, vehicle windshield washing fluid or Anti-Freeze,
RATED FOR MINIMUM -40°C.
3. Connect the pressure wand assembly.
4. Start the engine and engage the trigger on the pressure gun. Operate
the system until the fluid runs the same color as the windshield washing
fluid. Your machine is now prepared for storage.
5. Blow out, disconnect fluid supply & pump o ut excess or cap end