25
Q13, Q14
MOSFET
D-S
short
or
open
U7
Photo coupler
Input and output
short or open
R136,R144,R143,R130,R129,R141,R145,R139,R137
,R125,R126,R138,
Resistance
Short or open
INV
D3, D4, D5, D6, D7, D8, D12, D13, D15, D16
Diode
Short or open
R42, R43,R48, R54, R56, R60, R193, R194, R182,
R210, R208, R209, R78, R83, R87, R95, R49, R55,
R57, R61, R77, R82, R86, R94, R59, R157, R177,
R179,R88,R180,R193,R182,R157,R177,R208,R209,
R179,R180
Resistance
Short or open
Q10,Q2,Q16,Q8
Diode
Short or open
U1,U2,U3,U4
Photo coupler
Input and output
short or open
QA1, QA2, QB1, QB2, QC1, QC2, QD1, QD2
IGBT
C-E
short
or
open
MAIN
SPS
Q2
MOSFET
D-S
short
or
open
D1, D7, D6, D3, D2, D8,D9,D20
Power Diode
Short or open
U4
Optocoupler
Input and output
short or open
U3
Control IC
Power Pin and
o/p pin short
R7, R11
Resistance
Short or open
AC EMI
F1, F2, F3, F4
Fuse
Open
Note:
If the fuse is in “open” status, don’t replace the fuse only. In most of cases, open
fuse is caused by other failed components. Therefore, before restarting the Inverter, you
must find all failed components and replace them.
Note:
Ensure all the failed components have been replaced, then supply the low voltage
and check the control signal. Only when the control signal is OK, you can start the
Inverter.
Note:
If all power components function well, and all cables are connected correclty, but
the inverter still can’t start up, we suggest you to replace a new CNTL board.