background image

COMPRESSOR OPERATION

1. 

Before each use, pull and release the Pressure Release 
Safety Valve 

(Fig 4)

 to verify it is not stuck.

2. 

Plug the power cord into an appropriate 120 VAC, 60 Hz,  
15 Amp minimum, grounded outlet.

3. 

Move the Power Switch to the “ON” position 

(Fig 2)

.

4. 

Allow the Tank pressure to build to 150 PSI [10.3 bar] 
before each use. With the Air Compressor turned on, 
operation is automatic and under the control of the internal 
Pressure Controller. It will turn off @ 150 PSI [10.3 bar] and 
automatically restart @ 120 PSI [8.3 bar]. 
 

 
 

 

5. 

To Increase regulated output pressure, rotate the Regulator Knob Counter-clockwise. To decrease regulated output pressure, rotate the Regulator Knob 
Clockwise 

(Fig 4)

.

To Tighten:

1. 

Loosen four Motor Mount Bolts with two 13mm wrenches  
(NOT INCLUDED) 

(Fig 14)

.

2. 

Push Motor outward to increase belt tension, tighten bolts  
then re-check belt deflection.

3. 

Re-install Belt Guard. Tighten all fasteners securely.

8

 

Eastwood Technical Assistance: 800.544.5118  >>  [email protected]

To order parts and supplies: 800.345.1178  >>  eastwood.com 

5

FIG. 4

INJURY HAZARD!

  This unit starts 

automatically. ALWAYS shut off the compressor, 
remove the plug from the outlet, and bleed all pressure 
from the tank before servicing the compressor, and 
when the compressor is not in use.

 

The Pressure Gauge located on left side under the “ON/OFF” Pressure Switch indicates actual tank pressure (Fig 4).
The Pressure Gauge located on the right under the Regulator indicates regulated outlet pressure (Fig 4).

Regulated 

Pressure

 

Only 

slightly

 open the water Drain Valve to blow air and moisture out of the Tank. 

USING THE PRESSURE RELEASE SAFETY VALVE MANUALLY

In addition to emergency over pressure relief function, the Pressure Release Safety Valve can be used when rapid tank air pressure release is desired. To do so:

1. 

Move the Power Switch to the “

OFF

” position and unplug Power Cord. 

2. 

Pull and hold the Pressure Release Safety Valve ring to release pressure from the Tank 

(Fig 4)

.

3. 

When all pressure is released, release the ring on the Pressure Release Safety Valve.

CONDENSATION DRAIN

In normal use particularly in humid environments, moisture will condense and collect in the tank. It must be used daily to drain all accumulated moisture. Failure 
to do causes internal tank corrosion, perforation and ultimate failure. Tank moisture draining procedure:

1. 

Move the Power Switch to the 

“OFF”

 position 

(Fig 2)

 and unplug Power Cord.

2. 

Pull and hold the Pressure Release Safety Valve ring to release pressure from the Tank until the Tank Pressure Gauge reads less than 20 PSI 

(Fig 2)

.

3.  Slowly

 open the Drain Valve 

(Fig 1)

 

 

 
 
 

 

 

4. 

Drain moisture from tank into a suitable container.

 

Opening it all the way or too quickly will cause contaminated water to be blown out at high velocity. Wear appropriate eye protection.

 

Condensate is a polluting material and should be disposed of in compliance with local regulations.  
If drain valve becomes clogged, release all air pressure, remove and clean valve, then reinstall.

MAINTENANCE 

(CONTINUED)

ADJUST BELT TENSION

1. 

Turn-off the Automatic Switch and unplug the Compressor from the 
electrical power source before adjusting belt.

2. 

Disconnect Air Line from Compressor Air Outlet.

3. 

Remove Outer Belt Guard by first removing the three Socket Head Cap 
Screws and Washers along the lower rear of the Outer Guard 

(Fig 12)

 

with a 6mm Hex Key (NOT INCLUDED).

4. 

Next, remove the eight Square Retainers 

(Fig 13)

 by rotating each 

90° with a 17mm wrench (NOT INCLUDED).

5. 

Check Belt tension by placing a straightedge along the top run of the 
Belt then pushing down on the belt in the center of the run between 
the large and small pulleys. At proper tension, the belt should deflect 
approx. 1/2" [1.3cm].

FIG. 12

FIG. 13

FIG. 14

INJURY HAZARD!

  This unit starts automatically. 

ALWAYS shut off the compressor, remove the plug from the 
outlet, and bleed all pressure from the tank before servicing the 
compressor, and when the compressor is not in use.

- Fan Blade can start at any time. To help avoid personal injury,  
  keep hands clear.
- Do not use the unit with the Cover removed. Severe injury could  
  occur from contact with moving parts.

BURN HAZARD!

  The Pump generates heat  

during operation. 
-  Touching the Pump while running & for a considerable time afterward  
  will cause burns.
-  Use caution when servicing to avoid burns.

Regulator

Tank 

Pressure

Pull

Pressure 

Release

Rotate 

Blocks 

90°

2 of 4  

Motor Mounts

Содержание 31915

Страница 1: ... Department 800 544 5118 email techelp eastwood com PDF version of this manual is available online eastwood com 31915manual The Eastwood Company 263 Shoemaker Road Pottstown PA 19464 USA US and Canada 800 343 9353 Outside US 610 718 8335 Fax 610 323 6268 eastwood com OPTIONAL ITEMS 31733 Rockwood 3 8 NPT Air Filter Regulator 51537 3 8 Garage Air Line Kit 70491 Eastwood Industrial Air Hose 3 8 x 25...

Страница 2: ...n death or serious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury SAFETY INFORMATION The following indicators are displayed in this manual on the labeling and all other information provided with this product READ INSTRUCTIONS Thoroughly ...

Страница 3: ...s condition BURN HAZARD Touching the Pump while running and for a considerable time afterward will cause burns Use caution when servicing to avoid burns BURST HAZARD Check the manufacturer s maximum pressure rating for air tools and accessories Compressor outlet pressure must be regulated to never exceed the maximum pressure rating of the tool Relieve all pressure through the hose before attaching...

Страница 4: ...erheating the compressor must be kept a minimum of 12 inches 31 cm from the nearest wall in a well ventilated area DO NOT allow the Cover ventilation holes to be blocked or possible permanent damage could occur Air Line Connection The Eastwood 29 Gallon Compressor is designed with a convenient pre installed 3 8 Female Quick Disconnect at the air outlet and is compatible with most 1 4 NPT 3 8 Male ...

Страница 5: ... particularly in humid environments moisture will condense and collect in the tank It must be used daily to drain all accumulated moisture Failure to do causes internal tank corrosion perforation and ultimate failure Tank moisture draining procedure 1 Move the Power Switch to the OFF position Fig 2 and unplug Power Cord 2 Pull and hold the Pressure Release Safety Valve ring to release pressure fro...

Страница 6: ...ex Key NOT INCLUDED 4 Place a suitable container under the Drain Hole and allow the oil to run into it It may be helpful to place wedged under the wheels to allow the Compressor to tilt forward slightly to aid in complete oil removal 5 Replace Drain Plug and tighten securely with a 5mm Hex Key NOT INCLUDED 6 Remove the black plastic Oil Fill Plug from the upper right front corner of the Crankcase ...

Страница 7: ...ex Key NOT INCLUDED 4 Place a suitable container under the Drain Hole and allow the oil to run into it It may be helpful to place wedged under the wheels to allow the Compressor to tilt forward slightly to aid in complete oil removal 5 Replace Drain Plug and tighten securely with a 5mm Hex Key NOT INCLUDED 6 Remove the black plastic Oil Fill Plug from the upper right front corner of the Crankcase ...

Страница 8: ... particularly in humid environments moisture will condense and collect in the tank It must be used daily to drain all accumulated moisture Failure to do causes internal tank corrosion perforation and ultimate failure Tank moisture draining procedure 1 Move the Power Switch to the OFF position Fig 2 and unplug Power Cord 2 Pull and hold the Pressure Release Safety Valve ring to release pressure fro...

Страница 9: ...erheating the compressor must be kept a minimum of 12 inches 31 cm from the nearest wall in a well ventilated area DO NOT allow the Cover ventilation holes to be blocked or possible permanent damage could occur Air Line Connection The Eastwood 29 Gallon Compressor is designed with a convenient pre installed 3 8 Female Quick Disconnect at the air outlet and is compatible with most 1 4 NPT 3 8 Male ...

Страница 10: ...s condition BURN HAZARD Touching the Pump while running and for a considerable time afterward will cause burns Use caution when servicing to avoid burns BURST HAZARD Check the manufacturer s maximum pressure rating for air tools and accessories Compressor outlet pressure must be regulated to never exceed the maximum pressure rating of the tool Relieve all pressure through the hose before attaching...

Страница 11: ...n death or serious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury SAFETY INFORMATION The following indicators are displayed in this manual on the labeling and all other information provided with this product READ INSTRUCTIONS Thoroughly ...

Страница 12: ... Department 800 544 5118 email techelp eastwood com PDF version of this manual is available online eastwood com 31915manual The Eastwood Company 263 Shoemaker Road Pottstown PA 19464 USA US and Canada 800 343 9353 Outside US 610 718 8335 Fax 610 323 6268 eastwood com OPTIONAL ITEMS 31733 Rockwood 3 8 NPT Air Filter Regulator 51537 3 8 Garage Air Line Kit 70491 Eastwood Industrial Air Hose 3 8 x 25...

Отзывы: