background image

4

 

Eastwood Technical Assistance: 800.343.9353  >>  [email protected]

ASSEMBLY

•  Thread the Regulator unit 

into the 1/2” FNPT port  
on the right side of the 
Housing 

(FIG 1)

.

•  Thread the Regulator Key 

into the opening at the 
front of the Regulator  
unit 

(FIG 1)

.

INSTALLATION

•  The Filter/Regulator should be installed as close as possible to any air tools and spray guns  

to be used.

•  Securely mount the Filter/Regulator unit in a vertical position using the integral mounting 

bracket.

•  Connect the air inlet to the 1/2” FNPT at the cast-in, “AIR IN” port of the Housing 
•  Be sure to connect outlet to a clean air hose to prevent contamination of the filtered & dried air. 
•  Open inlet valve to pressurize system and check for leaks.

 

  Shut-off and release all pressure from air lines and the system before  

attempting any installation, servicing or performing any maintenance.

 

  A suitable air shut-off valve (Not Included) should be installed before the 

Filter/Regulator so the unit can be easily depressurized for servicing.

FIG. 1

Содержание 31633

Страница 1: ...COMPLETE FILTRATION SYSTEM INSTRUCTIONS Item 31633...

Страница 2: ...Hex Key 1 8 Adapter Stem To accept optional Eastwood 51567 or DeVilbiss 130524 Desiccant Kit SPECIFICATIONS 1 2 NPT Female Inlet 1 4 NPT Male Outlet Maximum service pressure 150 PSI 10 3 bar Air flow...

Страница 3: ...YE INJURY HAZARD Always wear ANSI Z87 approved eye protection when operating this Air Filter Regulator Air moisture and debris can be ejected at high velocity while using this equipment HEALTH HAZARD...

Страница 4: ...tor unit in a vertical position using the integral mounting bracket Connect the air inlet to the 1 2 FNPT at the cast in AIR IN port of the Housing Be sure to connect outlet to a clean air hose to pre...

Страница 5: ...ter every use To Drain Rotate the Petcock in a Counter Clockwise direction as viewed from the bottom to drain FIG 3 Allow accumulated moisture to drain When moisture stops flowing rotate the Petcock i...

Страница 6: ...Key remove the Canister from the Housing FIG 5 Dry any residual moisture remaining inside the Bowl Remove the wing nut metal end cap filter cup metal deflector and large rubber seal and save for futur...

Страница 7: ...Seal to center boss of housing and Large Rubber Seal to machined groove FIG 8 Place Plastic Desiccant Canister over center boss and Rubber Seal thread on wing nut and tighten securely FIG 9 Reinstall...

Страница 8: ...FIG 11 Dry any residual moisture remaining inside the Bowl Remove the wing nut metal end cap filter cup metal deflector and large rubber seal Save wing nut metal end cap cup and metal deflector for r...

Страница 9: ...Seal to machined groove FIG 13 In order reassemble over center boss metal deflector flange up cup filter metal end cap and tighten wing nut securely FIG 14 Reinstall Canister to Housing and tighten so...

Страница 10: ...10 Eastwood Technical Assistance 800 343 9353 tech eastwood com NOTES...

Страница 11: ...To order parts and supplies 800 343 9353 eastwood com 11 NOTES...

Страница 12: ...stwood Company 263 Shoemaker Road Pottstown PA 19464 USA 800 343 9353 eastwood com ADDITIONAL ITEMS 51567 DeVilbiss QC3 Air Filter Desiccant Refill 31882 Eastwood C F S Filter 51537 RapidAir Master Ga...

Отзывы: