REPLACE BLAST MEDIA
• To drain blast media from Blast Cabinet:
- Disconnect air supply to Blast Cabinet.
- Place a box or container suitable for holding the blast
media under the Drain Panel of the Hopper.
- Carefully release the Clasp of the Drain Panel Latch
(FIG 26)
.
- Allow the media to drain. Gently thumping the sides of
the Hopper may be helpful in maintaining media flow.
- When draining stops, clear excess media from
seal area of the Drain Panel, close and latch the
Clasp securely.
- Add Eastwood approved Blast Media. Fill to within
10” of the Perforated Floor support flanges.
DO NOT OVERFILL. Overfilling will degrade
performance.
DO NOT USE SAND IN THIS BLAST CABINET!
NOTE:
for best results and to avoid nozzle clogging,
do not use media larger than 60 grit particle size.
FIG. 26
The fine dust accumulated by this unit is a Health Hazard! Avoid breathing dust produced by handling the Filter. Always wear ap-
propriate NIOSH approved breathing apparatus when cleaning, emptying or maintaining the unit and use in a well-ventilated area.
Always dispose of exhausted media properly following all local hazardous material disposal regulations. Levels of hazardous
materials such as lead, zinc chromate, etc. may be present in coatings being removed. Additional precautions may be required
in the presence of these substances.