ABRASIVE MEDIA
BLAST CABINET – B100
INSTRUCTIONS
Item #21301
Страница 1: ...ABRASIVE MEDIA BLAST CABINET B100 INSTRUCTIONS Item 21301 ...
Страница 2: ... Peel Off Lamp Protection Panel Shields 3 Spare Nozzles 1 Roll Teflon Tape HARDWARE 35 M6 x 12mm Pan Head Screws 35 M6 Self Locking Nuts REQUIRED FOR USE The inlet air supply must have a moisture separator capable of removing all moisture and impurities from the air supply Moisture and or oil in the air supply will cause clumping and clogging of the abrasive media The included regulator must be us...
Страница 3: ...nd personal injury DO NOT exceed 90 psi 6 3 bar of tool inlet air pressure HEALTH AND INJURY HAZARDS The Eastwood Abrasive Media Blast Cabinet consists of large heavy metal components which can cause potentially serious injuries if allowed to drop Avoid pinching hands while handling parts during assembly The assistance of a helper during assembly is necessary The use of safety shoes is advised Abr...
Страница 4: ...loosen the six M6 screws holding it in place at the underside of the roof of the Cabinet Carefully withdraw the Light Fixture D and the Glass Lamp Protection Panel F Set the Light Fixture D and the Glass Lamp Protection Panel F aside in a secure location along with the six removed screws for top of Cabinet installation later The Eastwood Abrasive Media Blast Cabinet consists of large heavy metal c...
Страница 5: ...naccessible at this point Pass 2 M6 x 12mm Screws through holes from the outside add M6 Nuts FIG 4 Tighten securely Place another Leg B over the front corner of the Cabinet A aligning 4 sets of holes NOTE It is advisable to have a helper support the Leg while aligning holes and installing hardware Insert 4 M6 x 12 mm Screws from the outside and add 4 Nuts FIG 5 Repeat for front and rear legs at op...
Страница 6: ...oved hands along rubber seal inside the open light fixture slot at the top of the Cabinet and lift slowly and steadily to upright position DO NOT allow legs to collapse Align all holes in Legs and Cabinet and add an additional 4 sets of Screws and Nuts per side Tighten all hardware securely FIGS 7 8 The following step requires the assistance of a capable helper as the unit is very heavy When raisi...
Страница 7: ...TO TOP OF CABINET LOCATION D F TO A Place the Light Fixture on its back and remove the Florescent Tubes E from packaging Align contact pins at the end of Fluorescent Tubes with the spring loaded lamp receptacles FIGS 9 10 push in and allow pins at opposite end of Tube to fit into opposite receptacle FIG 9 FIG 10 ...
Страница 8: ... FIG 11 Place the Light Fixture D with Switch facing forward over the Glass Panel F and align the 3 mounting slots per side with the 6 holes in the cabinet top FIG 12 Add the 6 previously removed Light Fixture Screws NOTE No nuts are required as these are pre attached weld nuts FIG 13 Wear appropriate work gloves to avoid receiving cuts from sharp edges of the lass panel F 8 Eastwood Technical Ass...
Страница 9: ...tom right of the Hopper section of the Cabinet A Align the mount ing holes of the bracket with the 2 holes in the right front Hopper panel and secure it with 2 M6 Screws and Nuts FIG 14 Slip the end of the Orange Air Supply Hose over the inner nipple of the 90 Bulkhead Fitting and secure it with the Compression Ring FIG 15 FIG 14 FIG 15 ...
Страница 10: ...ABINET FLOOR H Let the Abrasive Blasting Gun and Hose G hang out of the right front corner of the Cabinet Set the Perforated Cabinet Floor H with angled cut off corner toward right front of cabinet and allow the edges to rest on the internal Cabinet support flanges FIGS 16 17 FIG 16 FIG 17 ...
Страница 11: ...ir Valve in place on the upper front face of the Left Leg align the mounting holes of the bracket with the 2 holes in the Leg and secure it with 2 M6 Screws and Nuts FIG 18 Slip the end of the Orange Air Supply Hose over the outer nipple of the 90 Bulkhead Fitting and secure it with the Compression Ring FIG 19 FIG 18 FIG 19 ...
Страница 12: ...l the Motor Filter out of the top of the Housing and set it aside With the assistance of a helper align the mounting holes of the brackets with the 4 holes at the upper back wall of the Cabinet Secure it in place using 4 sets of M6 Screws and Nuts FIG 20 Carefully lower the Motor Filter Assembly back into the mounted Housing and latch the Clasps securely FIG 21 Connect the Plug on the power supply...
Страница 13: ...Open the front loading Lid place object to be blasted on the Perforated Floor Panel Open the Air Inlet Valve on the Regulator Air Inlet Assembly FIG 24 The included Regulator is used to limit incoming air pres sure The Regulator should be adjusted to 90 PSI maxi mum Excessive air pressure can cause permanent damage to the unit Connect to a properly grounded 120V AC 20 Amp 60Hz outlet Close and sec...
Страница 14: ...r or alcohol Peel off adhesive protective strips and apply replacement shield to interior glass surface Press on adhesive areas to ensure an abrasive proof seal CERAMIC NOZZLE REPLACEMENT Replace the Nozzle when you notice excessive air and blast media being used or cleaning efficiency is reduced Nozzle replacement on the Blast Gun is easy After disconnecting the unit from the air supply unthread ...
Страница 15: ...n 10 of the Perforated Floor support flanges DO NOT OVERFILL Overfilling will degrade performance DO NOT USE SAND IN THIS BLAST CABINET NOTE for best results and to avoid nozzle clogging do not use media larger than 60 grit particle size FIG 26 The fine dust accumulated by this unit is a Health Hazard Avoid breathing dust produced by handling the Filter Always wear ap propriate NIOSH approved brea...
Страница 16: ...IG 28 Pull the Filter free of the Motor Unit Clean dust from the rubber seal Using a suitable blow gun and compressed air source blow air through the Filter from the inside out When done replace Filter and secure it with the Filter Retaining Washer and Wingnut Replace the Motor Filter assembly back into the Housing and latch the Clasps securely Reconnect the Power Supply Cord The fine dust accumul...
Страница 17: ...To order parts and supplies 800 343 9353 eastwood com 17 A B B B B C D E F Assembled G H J K Assembled Included with A Assembled Included with A J ...
Страница 18: ...18 Eastwood Technical Assistance 800 343 9353 tech eastwood com NOTES ...
Страница 19: ...ir supply Debris or Blasting Residue in Gun Nozzle Clean out gun nozzle then drain and sift blast media to remove debris before re use Excessive Media in Hopper For best results operate blaster with the Pick up Tube inlet buried several inches in media 50 lbs of media is generally sufficient Media Stream Suddenly Stops Dirt or Debris in Media Suction Line to Gun To dislodge blockage with lid close...
Страница 20: ...22018 Walnut Shell Media 12 20 Grit 13779 Ground Glass Media 40 70 Grit 13772 Glass Bead Media 100 170 Grit 22023 Glass Bead Media 70 100 Grit 11806 Soda Media 10 lbs 21135 Replacement Nozzles 2pc Copyright 2019 Easthill Group Inc 2 19 Instruction item 21301Q Rev 1 If you have any questions about the use of this product please contact The Eastwood Technical Assistance Service Department 800 343 93...