background image

6

 

Eastwood Technical Assistance: 800.544.5118  >>  [email protected]

NOTE:

  NEVER USE THE TORQUE WRENCH WHEN THE BATTERIES ARE LOW. THE ACCURACY OF 

READINGS WILL BE AFFECTED.

•  The display will not show a reading until the applied force has exceeded 10% of full scale.
• 

“- - - -”

 will be shown on the screen, when applied torque has exceeded 5% of the maximum 

of torque value. (See specifi cations)

APPLYING PROGRAMMED ANGLE

1.

  Program the value necessary following the instructions in the 

Target Angle Setting

 section. 

2.

  Place the torque wrench on the fastener. Press the             button to switch from torque 

measurement to angle measurement. The screen will display  

“ - - - - ”

  while it calibrates 

the orientation of the wrench. Once the screen displays  

“ 0° ”

, you may proceed.   

3.

  Grip the torque wrench and PULL on the wrench with a slow, easy movement. Avoid jerky 

movements.

4.

  With the target angle pre-set, the target value is indicated on the screen.

5.

  The LED will show 

GREEN 

when you under 50% of the programmed angle value.

6.

  When approaching the target angle value, the LED turns to 

YELLOW

.

7.

  When you approach the target angle value, the buzzer will sound.

8.

  When you are 

within 2%

 of the programmed value, the 

RED

 LED will illuminate. 

Once the angle is reached, the buzzer will emit a quicker sound sequence.

9.

 If 

you 

exceed the programmed angle by 2%

, the buzzer will emit a continuous tone and 

the LED will turn 

GREEN

.

ATTENTION: When you hear the continuous tone and the RED LED illuminates, stop pulling 
immediately or target torque will be exceeded.

TORQUE WRENCH USE AND CARE

•  Do not exceed the permitted maximum torque value for this tool. Over torquing the unit can 

cause permanent damage.

•  Be sure all accessories including adaptors, extensions and sockets are rated to match or 

exceed the torque being applied.

•  Use the correct size socket for the fastener.
•  Do not use sockets that are cracked or damaged.
•  Do not use the Torque Wrench near corrosive gas or liquid.
•  Keep away from strong magnetic fi elds.
•  Never hold or operate the unit with wet or greasy hands.
•  Never apply torque when the tool is turned off or permanent damage can occur.
•  Check that the Torque Wrench capacity matches or exceeds each application before proceeding.
•  Do not drop and avoid excessive bumps or shock to this tool.
•  If the tool is to be unused for an extended period of time, remove the batteries to prevent 

damage from leakage.