7
REPLACEMENT CARTRIDGE INSTRUCTIONS
CLEANING CARTRIDGE ASSEMBLY
CLEANING CARTRIDGE ASSEMBLY
NEVERCOLD™
NEVERCOLD™ pumps are specifically designed to prevent solid particles from
entering the bearing / rotor chamber of the cartridge. However, in systems heavily
contaminated by dirt, construction debris, etc., particles may enter the chamber on
initial filling of the system and on rare occasions cause rotor blockage.
The NEVERCOLD™
NEVERCOLD™ pump is designed to permit cleaning the interior of the cartridge
and de-blocking. To do so, separate the two parts (refer to #6 under “Replacing
Cartridge Assembly”) by grabbing the impeller and cartridge sleeve with opposite
hands and pulling apart. Clean (rinse) the two parts and re-assemble. Follow the
procedure under “Replacing Cartridge Assembly.” It is also recommended to flush
the system.
REPLACING CARTRIDGE ASSEMBLY (Replacement cartridge sold separately)
REPLACING CARTRIDGE ASSEMBLY (Replacement cartridge sold separately)
1. Disconnect power.
2. Reduce system pressure to zero and let fluid cool down.
3. Close shut off valves. If there are no shut off valves, drain system.
4. Remove pump housing bolts and pull out motor assembly.
5. Remove cartridge. Insert screw drivers between motor housing and square plate
and force cartridge out.
6. Insert new cartridge. Cartridge consists of two parts
7. Install new motor assembly using new O-ring gasket. Make sure gasket is
properly placed.
8. Follow installation procedure to start up circulator.