MECHANICAL TIMER OPERATION

The timer will turn the circulator on and off based on the times when hot water is  

needed. This may only be in the mornings and evenings depending on the 

schedules of the residence.

SETTING INSTRUCTIONS

1. To set the current time, rotate the outer ring until the arrow head lines up with the

     correct time. This is a 24-hour clock so 1 to 12 on the clock indicates 1AM to noon

     and 13 to 24 on the clock indicates 1PM to midnight.

2. To set the time that the pump will operate, move all the tabs outward during the

     time period. (Fig. 1)

     Example: To set ON at 7:00AM and OFF at 10:00AM move all of the tabs between

     7 and 10 to outward position.

3. By following the instructions in step 2 multiple on-off cycles can be set.

4. The override switch has 3 positions. (Fig. 2) The “I” indicates the pump will run 

     continuously (24 hours a day) The position next to the clock symbol indicates the

     pump will follow the settings of the tabs. The “O” indicates the pump is off 
     (not running).

Fig. 1

Fig. 2

6

Содержание NEVERCOLD 1613092

Страница 1: ...USER MANUAL FROM INSTALLS ON WATER HEATE ...

Страница 2: ...er up to 12 000 gallons a year Save energy save on utility and sewer fees GO GREEN help conserve this precious resource TUB HOT SUPPLY COLD SUPPLY TEMPERED RETURN HOT WATERTANK NEVERCOLD CIRCULATOR WITH BUILT IN TIMER NEVERCOLD VALVE TEE AND HOSE SHOWER SINK for more information visit nevercoldwater com ...

Страница 3: ...cal shock disconnect power prior to connecting or disconnecting NEVERCOLD WARNING Risk of electric shock NEVERCOLD has not been investigated for use in swimming pool or marine areas WARNING NEVERCOLD is acceptable for indoor use only Employer uniquement a l interieur CAUTION NEVERCOLD has been evaluated for use with water only The suitability of NEVERCOLD for use with liquids other than water is t...

Страница 4: ...installation has been completed 3 Remove the hot water line from the hot water heater at the threaded outlet pipe at the top of the tank 4 Place the large union nut over the threaded outlet pipe before threading the 3 4 NPT Tail Piece onto the threaded outlet pipe Fig 1 5 Place the union gasket on the tail piece and thread the large union nut onto the circulator Fig 2 6 Reconnect the hot water lin...

Страница 5: ... Fig 1 Flash Valve Hose Pump Timer Tee Fig 2 Fig 3 3 PARTS ...

Страница 6: ...hot and cold water faucets to relieve the water pressure 3 Disconnect the riser pipes or hoses from the angle stop valves Place a pan or rag below the connections to catch any water that may leak from the risers Fig 5 4 Attach the cold water riser to the 3 8 thread on the tee 5 Install the tee from the kit to the cold water angle stop valve using the 3 8 nut on the tee Fig 6 6 Attach the hose from...

Страница 7: ...ion on the Flash valve Fig 8 10 Open the hot and cold on the faucet Close angle to stop valves and purge air from the lines using the faucets NOTE The spacing dimensions between angle stops vary Fig 8 HOT WATER TANK INSTALL Pump installs on Water Heater Complete Installation FLASH VALVE Installs under fixture ...

Страница 8: ...noon and 13 to 24 on the clock indicates 1PM to midnight 2 To set the time that the pump will operate move all the tabs outward during the time period Fig 1 Example To set ON at 7 00AM and OFF at 10 00AM move all of the tabs between 7 and 10 to outward position 3 By following the instructions in step 2 multiple on off cycles can be set 4 The override switch has 3 positions Fig 2 The I indicates th...

Страница 9: ...ridge sleeve with opposite hands and pulling apart Clean rinse the two parts and re assemble Follow the procedure under Replacing Cartridge Assembly It is also recommended to flush the system REPLACING CARTRIDGE ASSEMBLY Replacement cartridge sold separately REPLACING CARTRIDGE ASSEMBLY Replacement cartridge sold separately 1 Disconnect power 2 Reduce system pressure to zero and let fluid cool dow...

Страница 10: ...control This warranty shall be invalidated by any abuse misuse misapplication or improper installation or maintenance of the product abuse misuse misapplication or improper installation or maintenance of the product NEVERCOLD makes no other warranties express or implied except as provided in this limited NEVERCOLD makes no other warranties express or implied except as provided in this limited warr...

Страница 11: ...IGN INSTANT HOT WATER Built in timer only runs pump when it is set to run Can be installed in less than 30 minutes Conserves up to 12 000 gallons of water per year Save time No more waiting for hot water at every faucet NO WAIT NO WASTE HOT WATER RECIRCULATION SYSTEM FOR MORE INFORMATION VISIT NEVERCOLDWATER COM ...

Отзывы: