DIAGNOSTICS
10
30SEP98 – 5B6333
Code
Description
Possible Malfunction
Action
E040
Loss of dryer heating ability A PANEL or DRYER RACK is not
installed.
Install the part.
SOLID STATE RELAY U3 that
controls the DRYER HEATER
Check U3.
RELAY K1 that enables the
DRYER HEATER
Check K1.
No continuity for the DRYER
HEATER
Check that the resistance at 25 C
(77 F) is approximately 16 W
DRYER OVER-TEMPERATURE
THERMOSTAT
Reset the THERMOSTAT. If the
THERMOSTAT opens again, determine
the cause of the high temperature. If
you cannot determine the cause of the
problem, install a new THERMOSTAT.
No continuity for the DRYER
HEATER THERMAL CUTOFF
Check that the DRYER BLOWER
operates correctly. Install a new
CUTOFF.
5000 BOARD:
• The 5000 BOARD does not
energize the SOLID STATE
RELAY U3.
• The RELAY K5001
malfunctions.
If the LEDs DS5 and DS6 on the 5000
BOARD are energized: If the 5000
BOARD has removable RELAYS,
install a new RELAY K5001. Otherwise,
install a new BOARD.