ADJUSTMENTS AND REPLACEMENTS
Replacements
06DEC05
AR4366-1
Page
70 of 219
S1/S4 and S12/S13 SENSOR BOARDS - EMITTER
Prerequisites:
1
Remove the
:
To Remove:
Caution
The weight of the CASSETTE INTERFACE
AY is 13 kg (29 lb).
1
Place the CASSETTE INTERFACE AY
on a flat surface.
2
Disconnect the CONNECTOR.
3
Remove:
•
2 SCREWS
•
if necessary, S1/S4 LEFT EMITTER
SENSOR BOARD
•
if necessary, S12/S13 RIGHT
EMITTER SENSOR BOARD
To Install:
Important
You must use a TORQUE WRENCH TL-1537 to tighten all Torx SCREWS to:
•
12 in./lb for T-10 size Torx SCREWS
H195_1027GC
S1/S4 LEFT
EMITTER SENSOR
S12/S13 RIGHT
EMITTER SENSOR
INTERFACE AY
CASSETTE
CONNECTOR
2 SCREWS
H195_1027GCA
BOARD
BOARD
Содержание 4366
Страница 4: ...ADJUSTMENTS AND REPLACEMENTS 06DEC05 AR4366 1 Page 4 of 219 Setting the Calibration 203 ...
Страница 45: ...ADJUSTMENTS AND REPLACEMENTS Adjustments 06DEC05 AR4366 1 Page 45 of 219 Postrequisites None ...
Страница 57: ...ADJUSTMENTS AND REPLACEMENTS Replacements 06DEC05 AR4366 1 Page 57 of 219 ...