Illustrated Parts List 27
Troubleshooting
Problem
Solution
Taper will not start
Check power input.
Release the Emergency
Stop button.
Press the Start button to
release overload.
Replace Fuse. (Access
fuse by removing plug
from underside of control
box as shown at right.)
Machine is not operating
Machine has inadequate electrical power or
power is not connected. Verify system power
meets specification requirements.
An Emergency Stop condition exists. Clear the
machine and reset the Emergency Stop.
Stuck carton
Check drive belt width adjustment.
Check for proper height adjustment.
Uneven or poor tape cuts
Adjust knife arm spring tension.
Adjust wipe roller spring tension.
Replace cutting knives.
Uneven Tape Leg on Front
Tape tension is too low. Tighten the one-way
clutch roller and/or the tape core.
Adjust the one-way clutch roller in the slot so it
is slightly beyond the front wipe roller.
Adjust the tape leg length. See Tape Leg
Adjustment section.
Содержание SB-2EX
Страница 1: ...SB 2 3EX Standard Stainless Industrial Case Taping System User Guide...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ...10 Introduction Dimensions Dimensions are shown in inches...
Страница 14: ...14 Installation...
Страница 26: ...26 Maintenance...
Страница 29: ...Illustrated Parts List 29 Parts List Electrical...
Страница 30: ...30 Illustrated Parts List Electrical Layout 11 12 17 18 16 19 20 14 13 15...
Страница 31: ...Illustrated Parts List 31 Electrical Layout Cont...
Страница 33: ...Illustrated Parts List 33 Side Belt Assembly...
Страница 38: ...38 Illustrated Parts List Vertical Column...
Страница 43: ...Illustrated Parts List 43 Machine Body...
Страница 50: ......