Adjustments 23
To set AL-1 so the machine will shut down at 150°, press the left-arrow key and the
right-most digit will flash. Use the up- or down-arrow key to select the digit, and then
press the left-arrow key again. Use the up- or down-arrow key to set the digit and
repeat until the correct value is displayed. Press MD to lock in the setting.
9. Press MD and scroll through the menu until LOC is displayed.
10. Press the left-arrow key. (OFF will begin flashing.)
11. Press the up-arrow key. (OFF changes to ON, and ON is flashing.)
12. Press MD. (On stops flashing.)
13. Press and hold the MD key until PV and SV temperatures are displayed.
Содержание ET1608-30
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 40: ...40 Parts List Parts List This page is reserved for information that may be added later ...
Страница 41: ...Parts List 41 This page is reserved for information that may be added later ...
Страница 44: ...44 Appendix A Electrical Schematics This page is intentionally left blank ...
Страница 45: ...Appendix A Electrical Schematic 45 Electrical Schematic ET1610 36 48 Variable Speed 220V 25A 3 Phase ...
Страница 46: ...46 Appendix A Electrical Schematics This page is intentionally left blank ...
Страница 47: ...Appendix A Electrical Schematic 47 Electrical Schematic ET2110 220V 40A Single Phase ...
Страница 48: ...48 Appendix A Electrical Schematics This page is intentionally left blank ...
Страница 49: ...Appendix A Electrical Schematic 49 Electrical Schematic ET2010 220V 25A 3 Phase ...
Страница 50: ...50 Appendix A Electrical Schematics This page is intentionally left blank ...
Страница 54: ......
Страница 55: ......