background image

 

 

HT64 

 

 

4.  SettingsMenus 

4.1.  Using Settings Menus 

 

Press OK button to open the Settings Menus,as show below. 

 

 

Press UP / DOWN button to select menu item or change the value of current 
focus item.  

 

Press  OK  button  to  enter  the  submenu  or  set  focus  on  the  current 
sellecteditem.PressESC button to return to the previous menu. 

 

If want to exit settings menus, can press HOLD button or press ESC button 
in root menu. 

4.2.  Settings details 

4.2.1.  Palette mode

 

Thermal imager has five kinds of palette,such as:

.\                              

Press OK button to select on of display color palettes. 

 

4.3.  Temp Unit

 

Press OK button to set focus on this option and the color of option value will change 
to blcak

.Infocus state, use the RIGHT / MENU button to toggle

,

 and K, use 

ESC / OK button to exit focus state and the color of option value will change to blcak

 

4.4.  Measure

 

Press  OK  button  to  enter  measure  menu.Two  selections  are  available:  Temp.Max 
and Temp.Min.Press OK button to set cur select item on  or off. 

 

Screening  mode:This  option  enables  thermal  imager  measure  surface 
temperature. 

 

Alarm temperature:In screening mode, if surface temperature is higher than 
alarm temperature, then buzzer alarm will be triggered. 

Содержание DT-870 Y

Страница 1: ...2016 Version EN 1 02 25 01 2016 Thermal imager User manual EASTERN ENERGY CO LTD HEAD OFFICE 40 4 Vitoondumri Rd Banbueng Banbueng Chonburi 20170 Tel 0 3844 6117 Fax 0 3844 6200 Email info ete co th C...

Страница 2: ...smart device Scene temperature range Lock function With LED flashlight function Long running time up to 8 hours with rechargeable battery Smart and compact design Rugged industrial design Safety 1 2...

Страница 3: ...hat the ed period o e battery s nect to an at top of th battery ch uter USB p powered up l screen sy to use utton for mal image ea or objec color hot perature o ture will dis the image gger again scie...

Страница 4: ...eading rigger e operation CK BUTTO Short press range a so ion is avail N Short pre age when utton when AVIGATION setting W Press and shlightSho o discard im ght Long p n of the con ON Press s to exit...

Страница 5: ...tery Charg SB Battery e Delete a rmal image er to captu image eit ages form as describe s are delet ptions Display button rrow button cess ACK button tions ht len ons ing LED in charging i and Revie e...

Страница 6: ...pale Batt ription its e readings rature read icon ette tery Full dings Battery c Cent Hot c Cold Unloc Lock Bluet charging tre crossha crosshair crosshair ck icon k icon tooth icon HT64 air 4 EASTERN...

Страница 7: ...argin Pic mperature pixels the current sc the corre the lock tem ject or an a to loc turn grey button switch the up screen the image g with an IR tion 3 2Po ng 5 1 start l level span rmal imag cene te...

Страница 8: ...the trigger to capture the image the image will freeze 3 If don t want to save the current image Short press the trigger again the image will unfreeze 4 Press SAVE to save the image 5 If the image is...

Страница 9: ...he Setting back butto ansfer the i ered succe or report th Pic5_ 5_5Receive mages h on the un devices co e Review m re the curre ansfer the i or report th to view or d gs Menu S n to exit th mage essf...

Страница 10: ...ens fo OV theoretical er detector ager uses s 17 Ver mrad OV theoretical cal 3 74 1 Vmeasure is e is 2 to 3 ement area he calculate ccess the S Bluetooth OV vertical OV Ve 21 View is the stance the oc...

Страница 11: ...te such as Press OK button to select on of display color palettes 4 3 Temp Unit Press OK button to set focus on this option and the color of option value will change to blcak Infocus state use the RIG...

Страница 12: ...tion ena tion enab e point tion enab e point focus on th missivity s o 0 99 in 0 enter langu nese and t selected In screen bles therm bles therm bles therm his option value useE 01 steps uage menu Eng...

Страница 13: ...nter setu button to s K button to change ailable brig button to choose the h function upmenu Th set bluetoo to set foc e LCD s br ghtness s set focus e time pe on the inst hree optio oth power cus on...

Страница 14: ...Touch the device name listed in bluetoothsheet it will be transmitted to laser distance meter measuring interface after connection The detail information about Thermview please refer to MeterBox Pro...

Страница 15: ...ing Se mory card r timemenu et The ch r memory m ssOK butt mediately Press OK elect YES d u In this m anges tak menu Two ton to ent K button S will dele enu yeas ke effect a ooptions ar ter image dial...

Страница 16: ...yed a tton to en ware s vers ect Factory as show be ter system ion and the y Set opti elow Selec m infomatio ermal imag ion after ct YES bu onmenu T ger s versio press OK utton syste his menu on butto...

Страница 17: ...eys to exit Image Browser mode 1 Current displayed picture s filename 2 Current picture s index and total number of pictures 3 Temperature of center point 4 Picture display area 5 2 How to capture scr...

Страница 18: ...32 C and42 Display 2 color TFT LCD screen Display resolution 240x320 pixels resolution Battery Rechargeable 3 7V 1300mA lithium ion battery not user serviceable Battery lift 6hours typical Battery Cha...

Отзывы: