background image

Connect power controller to the terminal on the machine, then connect the power
cord with power supply and make sure it is 208-240v single phase 60hz.
Turn power supply on to start the machine.

DAILY MAINTENANCE

1. Do shut down the power supply before maintenance.
2. Wipe the body with soft cloth in daily use. Use a wet hard cloth to wipe dirty
body, or use a soft cloth moistened with a little diluted neutral detergent.
3. Filter Cleaning: it will affect the dehumidifying effect or cause malfunction if
accumulate dust on filter , it needs to be cleaned regularly, clean it at least once a
month.Use dust catcher to remove dust or put filter into clean water (<40

) to

wash, then place filter back after cleaning.
NOTE: The filter cannot be put in sunlight directly or roasted to avoid distortion.
The filter must be placed before power up machine.

4.

Non use of equipment :Cut the power or unplug power line. Place equipment in

dry and shaded area.

— 6 —

OPERATION GUIDE

Содержание SDD-150L

Страница 1: ...DEHUMIDIFIER SDD 150L INSTRUCTION MANUAL...

Страница 2: ...SAFTY INSTRUCTIONS 1 SPECIFICATIONS 2 UNPACKING THE DEHUMIDIFIER 3 INSTALLATION GUIDE 4 OPERATION GUIDE 6 STRUCTURE AND RUNNING 7 OVERALL PARTS 8 NORMAL MALFUNCTION REMOVAL 9 DIRECTORY...

Страница 3: ...not necessary to use dehumidifier when the room temperature is below 10 the absolute humidity is quite low at this condition 5 Please try to seal environment better to increase the effect of dehumidif...

Страница 4: ...umidity Range RH40 RH95 MECHANICAL Weight 125 lbs without packaging Drain Size 5 8 Capacity 320 Pints 86 F 80 RH Airflow 790 CFM free flow ELECTRICAL Voltage 208 230 VAC 1 60 HZ Operating Current 7 0A...

Страница 5: ...Automatic defrost protection function The dehumidifier will defrost automatically when freezing occurs The dehumidifier will start automatically when defrost process is complete Default defrost setti...

Страница 6: ...ng to the position of install hole on the machine then install the expansion screw to fix the thread rod B Install the machine through the four thread rods and adjust the height according the space to...

Страница 7: ...to fix the dehumidifier on the ceiling 3 Ensure the installation of dehumidifier is horizontal to avoid malfunction or leakage 4 Ensure drain tube is installed unhindered without overmuch bends 5 Ens...

Страница 8: ...d with a little diluted neutral detergent 3 Filter Cleaning it will affect the dehumidifying effect or cause malfunction if accumulate dust on filter it needs to be cleaned regularly clean it at least...

Страница 9: ...ith 1 RH scale in running mode Press the key to set the hour or minute down with 1 hour or 1 minute scale in timed on off or clock setting mode 5 Humi Press the key to set the humidity value down with...

Страница 10: ...Heat exchanger 13 Base bracket 4 Heat exchanger cover 14 Power cord pressing block 5 Top plate 15 Electrical box 6 High pressure pipe 16 Main control board 7 Low pressure pipe 17 Connection terminal 8...

Страница 11: ...2 POWER OFF 3 POWER IS NOT PLUG IN 4 BLOWN FUSE 1 RESUME POWER 2 POWER ON 3 PLUG IN 4 REPLACE FUSE BAD DEHUMIDIFICATION EFFECT 1 FILTER BLOCKED WITH DUST 2 AIR INLET IS BLOCKED 3 USED IN BAD SEALED RO...

Страница 12: ......

Отзывы: