![background image](http://html1.mh-extra.com/html/east-tester/et-ay30/et-ay30_user-manual_3440544012.webp)
10
7
HART Function
7.1 HART Interface
Long press the
“ENTER”
key to enter the menu, select the second
item "HART", and then the calibrator will automatically turn on the 24V
power output and send a handshake command to the transmitter
connected to the calibrator and read the parameters at the same time.
When the calibrator and the transmitter communicate successfully, it
will display as follows:
"Upper limit M" and "lower limit M" represent the maximum and
minimum pressures supported by the pressure sensor inside the
transmitter. "Pressure H" and "current H" represent the pressure value
and current values currently measured by the pressure transmitter.
Short press the
“MODE”
key under the HART function to switch
between the following two interfaces, which are the routine
measurement interfaces under HART function.