background image

Replacement of flannelette in backrest

1.

Press P6 to remove the cloak in the first step

2

.

Open 4 zippers of flannelette according to figure 1

3

.

Remove the two screws behind the back and the two screws under the pedestal As

shown in figure 2

4.

Replace the new flannelette with the steps in figure 2 and figure 1 to return to the

operation

图 1

图 2

7

Содержание EI-8602A-TIT

Страница 1: ...Xiamen Healthcare Electronic Co Ltd Maintenance Service Manual Model EI 8602A TIT Voltage Specification 110 120V By the Easepal s Customer Service Dept 1...

Страница 2: ...cement 2 9 7 Movement replacement 3 10 8 Remove the back cover 11 9 Replacement of upper cover of central box 12 10 Remove side plate 13 11 calves replacement 14 12 Movement backrest bus disassembly 1...

Страница 3: ...3 Replace the center board 3 The movement plate does not communicate with the center board for more than 4s Bad contact or fracture of inserting wire 1 Check or replace the plug in cable 2 Replacemen...

Страница 4: ...acement of sensors 3 Replacement of movement board 1 Detection when function is turned on 2 Shut down automatically in the event of failure time And not allowed to boot 54 The position of the Core kne...

Страница 5: ...Tools List Diagonal Cutter Electric Screw Driver Electric Screw Driver Cable Ties Cross Batch 2 6 35 65 Slot Type Screwdriver 2 6 35 100 Screwdriver 5...

Страница 6: ...Pass through the zipper head with a small Cable Ties and pull it apart figure 1 as shown in figure 2 after opening at 7th position 2 Put on the new cloak and zip up 7th position zippers as shown in fi...

Страница 7: ...the first step 2 Open 4 zippers of flannelette according to figure 1 3 Remove the two screws behind the back and the two screws under the pedestal As shown in figure 2 4 Replace the new flannelette w...

Страница 8: ...hole to move the machine core away from the guideway to remove the baffle area If the machine core does not block the baffle area of the guideway jump directly to the next step 3 Remove the baffle fr...

Страница 9: ...4 The walking gear comes out first and the front gear comes out again 8...

Страница 10: ...wn in figure 3 with Diagonal Cutter 6 Remove the earth wire of the machine core 7 Pull out the trachea and terminal 8 Connect the trachea to the terminal with a new machine core 9 Lock the earth wire...

Страница 11: ...2 The screwdriver removes the machine core away from the baffle area of the left and right guideway through the repair hole 13 install the Remove baffle of the left and right guideway on the guideway...

Страница 12: ...the power supply 2 Pull out the cloth pin on the back cover vertically as shown in figure 1 and remove the four screws in figure 2 3 Press down pull the back cover backward and pull out a certain ang...

Страница 13: ...5 cloth pins in turn perpendicular to the direction of the upper cover as shown in figure 1 3 Remove the screws as shown in figures 2 and 3 4 Hold the inner side of the top cover of the center box on...

Страница 14: ...ewdriver as shown in figure 4 6 Connect the power supply run the massage chair to the back state remove the screw at the front end of the side plate from below the calves as shown in figure 5 and then...

Страница 15: ...of calves 1 Unzipper as shown in figure 1 2 Break the DK Card bolt open with your fingers or pliers and take it up as shown in figure 2 3 Remove the trachea and power cord connector as shown in figure...

Страница 16: ...or removing the cloak and velvet through P7 step 1 3 2 Press P11 to remove the rear cover cut off the tie tape shown in the figure below pull out the terminal shown in the figure below and remove the...

Страница 17: ...wire 3 places The earth wire of the nine core connecting wire is locked to the rear cover of the movement One end of the spring is pierced into the buckle and fixed with the reserved band Pull spring...

Страница 18: ...line is connected to the 32 core wire 17 8 10 9 Movement backrest bus disassembly 3 Nine core connecting wire and 32 core wire earth wire with lock Straighten the line tie the belt and fix it 7 Cloth...

Страница 19: ...pump replacement 1 Remove 5 cloth sleeve pins on the top cover of the central box 2 Remove 3 screws 3 Remove 4 screws of the air pump and cut off the bandage so that you can take it out and replace it...

Страница 20: ...plug the terminal Remove the fixing screw from the transformer Remove transformer 2 Center plate replacement Unplug the terminal from the center board Remove 6 screws That is the center board can be r...

Отзывы: