6
Technical
specifications
General
Dimensions (mm): 256 x 193 x 106 (H x W x D)
Wall mounting (mm): c/c 160 x 125 (H x W)
Operating temperature: -30 °C to +50 °C
Weight: 1.5 kg
Warranty: 3 years (warranty may be longer in some
countries)
Charging
Charging power: 1.4–22 kW
6 A 1 phase – 32 A 3 phase (automatically
adjusted in relation to available capacity)
Up to 7.36 kW at 32 A 1 phase
Up to 22 kW at 32 A 3 phase (TN grid)
Connection point: Type 2 socket (IEC 62196-2)
Number of phases: 1 or 3 (fully dynamic)
Voltage: 3 x 400 V AC/ 230 V AC (±10 %)
Mains frequency: 50/60 Hz
Built-in energy meter (±2 %)
Easee Home: Load balancing of up to 3 units per circuit
Easee Charge: Load balancing of up to 101 units per circuit
Sensors and indicators
Light strip with LEDs showing the status of the charger
Touch button for manual adjustment
Temperature sensors in all main contacts
Connectivity
Built-in eSIM (LTE Cat M1/ 2G /GPRS)
WiFi 2.4 GHz b/g/n connection
Easee Link RF
TM
Control charging via Easee app
RFID/NFC reader
OCPP 1.6 via our API
Protection
Built-in RCD for ground fault protection (30 mA AC/
6 mA DC)
RCD is automatically reset by disconnecting the
charging cable
Degree of protection: IP54 (the backplate is IP22
without cover)
Impact resistance: IK08
Fire class: UL94
Insulation class: II
Overvoltage category III
Installation
Installation network: TN, IT and TT (detected
automatically)
Installation circuit breaker: Max 40 A (Easee Home) and
80 A (Easee Charge) overload protection. The short-
circuit current at the charging point (IkMax) must not
exceed 10 kA. If required by the installation method, class
A earth fault protection can be used for the circuit.
Cable cross-section: up to 16 mm
2
(single cable)/
up to 10 mm
2
(parallel connection)
Cable diameter: 8–22 mm
Terminal tightening: 5 Nm
Cable strip length: 12 mm