background image

5

Technical specifications

Dimension (mm): H: 1500 x W: 156 x D: 80
Weight: 6.1–7.7 kg
Material: Aluminium
Finish: Powder coating
Colour: Black
IP degree: IP44

Adapter plate for c/c 160 mm

2

 foundation

45 degree rotation intervals (using the adapter plate)
Screws and nuts included

Connection via Power Rail
Possibility of serial connection of posts

In and out of the post: Max 25 mm

2

Up to the Charging Robots : 6 mm

2

General

Features

Electrical connection

Cable size

Содержание Base

Страница 1: ...Installation guide Easee Base ...

Страница 2: ...IMPORTANT Read carefully before use Keep for future reference You can find other languages available on our website easee support ...

Страница 3: ...tions Safety instructions Common parts Adapter plate 1 Way 2 Way 3 Way 4 Way Power Rail Before connecting Ground connection plate Terminals Wiring Side panel Practical details 4 5 6 8 9 10 14 18 26 27 28 31 33 36 37 Table of contents ...

Страница 4: ...to health up to and including life threatening injuries The Easee Base is a modular charging post for mounting up to four Easee Charging Robots With Easee Base it is possible to choose between four different configurations One way setup where only one charger is mounted 2 way setup with two chargers 3 way setup with three chargers and finally 4 way setup where there is a charger on all sides of th...

Страница 5: ...ur Black IP degree IP44 Adapter plate for c c 160 mm2 foundation 45 degree rotation intervals using the adapter plate Screws and nuts included Connection via Power Rail Possibility of serial connection of posts In and out of the post Max 25 mm2 Up to the Charging Robots 6 mm2 General Features Electrical connection Cable size ...

Страница 6: ...circuit is closed and must never be in direct contact or in contact with anything other than the plug in electronics Chargeberry Depending on the type of installation official authorisations may be required prior to installation Danger to life due to high electrical voltage Never make any changes to components or connecting cables Always have the prescribed maintenance installation and any repair ...

Страница 7: ...hout knowledge of the product Make sure that children do not play with the product Do not use extension cords or unapproved adapters in combination with the product Even if the Charging Robot is designed to withstand normal weather conditions we recommend protecting it from direct sunlight or exposure to extreme weather conditions Do not use the product near strong electromagnetic fields or in the...

Страница 8: ...8 Screws washers and nut x4 x4 x1 Column Side panel Adapter plate Power Rail Ground connection plate Common parts ...

Страница 9: ...ion of the column to the adapter plate with 4 socket head screws Recommended torque is 30 40 Nm INFO It can be mounted in 45 increments to get the correct direction Column at a 45 angle A A A A A Common parts Adapter plate ...

Страница 10: ...10 1 Way ...

Страница 11: ...11 1 way blind cover 1 Way Parts Mounting plate x6 x4 Screws ...

Страница 12: ...Attach mounting plate and blind cover to the column with 3 flat head screws each 6 screws total NOTICE Make sure the top end of the column is sealed with a plastic cap A A A A A 1 Way Plate and cover 1 A A ...

Страница 13: ...13 Thread the cable through the hole in the column and the Easee charger backplate before attaching it with 4 rounded head screws B B B B B 1 Way Backplate 2 ...

Страница 14: ...14 2 Way ...

Страница 15: ...15 Mounting plates x6 x8 2 Way Parts Screws ...

Страница 16: ...16 Attach the mounting plates to the column with 3 flat head screws each 6 screws total NOTICE Make sure the top end of the column is sealed with a plastic cap 2 Way Plates 1 A A A A A A A ...

Страница 17: ...17 B B B B B B B B Thread the cables through each hole in the column and the Easee chargers backplates before attaching them with 4 rounded head screws 8 screws total 2 Way Backplates 2 B ...

Страница 18: ...18 3 Way 4 Way ...

Страница 19: ...19 3 Way 4 Way Parts x6 x20 Bottom frame Top plate Top frame 3 way blind cover Screws ...

Страница 20: ...20 A Slide the bottom frame over the column and fasten it to the lower threaded hole with 1 flat head screw on each side 2 screws total 3 Way 4 Way Bottom frame 1 A ...

Страница 21: ...21 A A Attach the top frame to the top two threads using 2 flat head screws on each side of the column 4 screws in total 3 Way 4 Way Top frame 2 A ...

Страница 22: ...he top frame with the top plate and fix it with 4 rounded head screws NOTICE Make sure that all cables are pulled through the column holes 2 on each side before attaching the chargers backplates 3 Way 4 Way Top plate 3 B ...

Страница 23: ... Easee chargers backplates to the sides perpendicular to the column openings with 4 rounded head screws each 8 screws total NOTICE Pull the cable through the hole in the backplates before attaching them 3 Way 4 Way First 2 chargers 4 B ...

Страница 24: ...kplate to one of the open sides and close the other one with the blind cover Before attaching the blind cover the shielding tab must be flipped up in order to mount the blind cover plate with 4 rounded head screws 3 Way 3 Way Last charger and cover 5 B B B B B ...

Страница 25: ...s backplates to the column with 4 rounded head screws each 8 screws total NOTICE Before installing the electronics in the backplates they must all be programmed please check the installation guide that came with the Charging Robots 4 Way 4 Way Last 2 chargers 5 B B B B B ...

Страница 26: ...26 Power Rail ...

Страница 27: ...ing system of the charging post which is described carefully in the following pages WARNING The Power Rail is a product to be installed by an authorized electrician and a declaration of conformity must always be provided upon completion by your installer WARNING Turn off the power before beginning the wiring Use extreme caution and follow instructions carefully ...

Страница 28: ...he plate is essential for connecting the post to the protective earth PE Make sure the top PE terminal screw is open then wedge the end of the plate into the terminal from the back The ground connection plate should lie flat to the plastic housing 1 Power Rail Ground connection plate 1 ...

Страница 29: ...rrated washer on the rod inside the column It should be placed between the metal column and the Power Rail Slide the Power Rail with the ground connection plate inside the column and latch the bottom of the rail into the catch ...

Страница 30: ... washer on the rod NOTICE In order to complete the PE connection the grounding nut has to be fastened and the top PE terminal screw has to be tightened regardless of whether there is a wire in it or not Important Do not forget this step NB B NB 4 ...

Страница 31: ...is lane is only used for PE connections We recommend using the two lower terminal sets for the main power cables One set of terminals is used for power in and the other is used for power out if you want to connect another charging post on the same cable Wire size up to 25mm Power in out Power Rail Terminals 2 PE lane ...

Страница 32: ...es For a single charger only one set of terminals is used for two chargers both sets of terminals are used and for three or four chargers two wires have to share a terminal Wire size up to 6mm Charger 1 Charger 1 Chargers 1 2 Charger 2 Chargers 3 4 1 Way 2 Way 3 Way 4 Way ...

Страница 33: ... grids Strip the cable cores by 12 mm If the cable has flexible conductors it is recommended to use cable end sleeves on all wires Tighten the screws with a torque of 5 Nm NOTICE Terminations should be visually and mechanically inspected before mounting the side panel Power Rail Wiring 3 1 2 PE 1 2 ...

Страница 34: ...erefore the preferred grid type for charging electric vehicles NOTICE Depending on the time of installation and national standards the colours of the cables can vary from the illustration below Therefore please make sure that the conductors are correctly terminated before applying power NOTICE The charger is designed for a TN grid type with 5 lead cable TN 3 phase TN 1 phase ...

Страница 35: ...ystems have no neutral connector and use only 4 conductors Therefore they can only provide 230 V across the phases NOTICE Depending on the time of installation and national standards the colours of the cables can vary from the illustration below Therefore please make sure that the conductors are correctly terminated before applying power IT TT 3 phase IT TT 1 phase ...

Страница 36: ...36 After connecting all wires to the Power Rail it is time to mount the side panel with the 4 rounded head screws Power Rail Side panel 4 C C C C C ...

Страница 37: ...ectly without the adapter plate in this case using a 80 x 80 center to center footprint For all the flat and rounded head screws we recommend 7 9 Nm of torque Contact your distributor or Easee Customer Support regarding the return and complaint of your product Download the latest manuals find answers to frequently asked questions and useful documents and videos for your product at easee support Fo...

Страница 38: ...ng retrieving data or computer networks without the written permission of Easee AS Easee and all other Easee product names and slogans are trademarks or registered trademarks of Easee AS Easee products can be protected by one or more patents All other products and services mentioned may be trademarks or service marks of their respective owners Illustrations of the product and user interface are ex...

Страница 39: ...39 ...

Страница 40: ...Easee AS Professor Olav Hanssens vei 7A 4021 Stavanger Norway easee international com ...

Отзывы: