stick every half year and change it if it has been used out
!
How to replace the magnesium anode
:
-
Turn the power of the unit ‘OFF’ and pull out the plug.
-
Drain all the water out of the tank.
-
Remove the old magnesium anode from the tank.
-
Replace the new magnesium anode.
-
Recharge the water.
Schematic overview of the water and refrigeration circuit
Choose the suitable unit
Please refer to the table below to choose the suitable unit.
Family members
Tank capacity
1 ~ 2 people
110L/150L
Note:
The table is just for reference.
hot water
outlet
cold
water
in
let
water tank
low pressure switch
temp
sensor
air inlet
compressor
evaporator
air outlet
temp sensor
2-way valve
electronic expansion valve
11