14
Table 6-3
--
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
NO.
Contents
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
NO.
Contents
Discharge temp. sensed port of the inverter
compressor A
Discharge temp. sensed port of the inverter
compressor A or B
Ttemp. sensed port of the inverter module radiator
Reserved
Reserved
Wiring port for communication between indoor and out
-door units,indoor unit network and network accounting
Phase inspection port
Power input of the No.1 transformer
Power input of the No.2 transformer
Loading output terminal
EXV A driving port
EXV B driving port
Loading output terminal
Loading output terminal
Loading output terminal
Power output of the No.1 transformer
Power output of the No.2 transformer
Activation port of inverter module B
Port for inverter module B voltage inspection
Port for inverter module A voltage inspection
Activation port of inverter module A
ON/OFF signal input port for system low pressure
inspection
ON/OFF signal input port for system high pressure
inspection
Reserved
Reserved
Reserved
Control port of DC fan A
Control port of DC fan B
Inspection port for outdoor ambient temp. and
condensator coil
Current inspection port of the inverter compressor
A and B
Power supply connected port of the main control panel
6.5 Dial indication sign instructions
S1 definition olny for 45kW:
ENC3 and S12 definition:
ENC1 definition:
ENC2 definition:
ENC4 definition:
Reserve
6.4 Outdoor main control board instructions
Set the number of indoor units
to 0-15
Set the number of indoor units
to 16-31
Set the number of indoor units
to 32-47
Set the number of indoor units
to 48-63
Outdoor unit capacity setting switch
4
:
12HP(335)/14HP(400)
5
:
16HP(450)
6
:
20HP(500)
Outdoor unit net address dial code 0-F valid
represents 0-15
Reserve
S2 definition olny for 45kW:
Reserve
S1 definition olny for 33.5kW40kW:
Starting time is set
about 5 minutes
Starting time is set
about 12 minutes
(Default the
Factory Set)
S2 definitionolny for 33.5kW40kW:
Night time selection
is 6h/10h (Default
the Factory Set)
Night time selection
is 6h/12h
Night time selection
is 8h/10h
Night time selection
is 8h/12h
V.2
Содержание EVRO-400RDC
Страница 1: ...MANUAL DE INSTALACIÓN Y MANUAL DE USUARIO MODELOS EVRO 400RDC EVRO 450RDC VRVV V 2 ...
Страница 2: ...2 ÍNDICE Manual de instalación 3 Manual de usuario 20 V 2 ...
Страница 27: ...INSTALLATION S AND OWNER S MANUAL MODELS EVRO 400RDC EVRO 450RDC VRVV V 2 ...
Страница 28: ...2 Table of contents Installation s manual 3 Owner s manual 23 V 2 ErP Information 30 ...
Страница 64: ...V 2 www easelectric es ...