2. SAFETY AND WARNINGS
1.
All persons who are responsible for mounting, installation, commis-
sioning, maintenance, tests, and service of EAS Electric inverter
products must be suitably trained and qualified for corresponding
operations. They MUST be experienced and have knowledge of
operation safety and professional methods. All installation personnel
must have knowledge of all applicable safety information, standards,
directives, and regulations.
2. The product must ONLY be connected and operated with PV arrays of
protection class II, in accordance with IEC 61730, application class A.
The PV modules must also be compatible with this product. Power
resources other than compatible PV arrays MUST not be connected
and operate with the product.
3.
When designing or constructing a PV system, all components MUST
remain in their permitted operating ranges, and their installation
requirements MUST always be fulfilled.
4.
Under exposure to sunlight, the PV array may generate dangerous
output in DC voltage. Contacts with the DC wires, conductors and live
components in the inverter may result in lethal shocks.
5.
High voltages in inverter could cause lethal electrical shocks. Before
proceeding any work, including maintenance and/or service, on the
inverter, fully disconnect it from all DC input, AC grid and other voltage
sources. There MUST be a 5-minute waiting time after the full
disconnection.
6.
The DC input voltage of the PV array MUST never exceed the
maximum input voltage of the inverter.
7.
DO NOT touch parts of the inverter during operation as heat will be
induced and these parts will exceed 60ºC.
3. UNPACKING
3.1 Scope of Delivery
Please inspect and check for completeness in the scope of delivery.
Confirm with purchase order.
INVERTER MOUNTING
BRACKET
MOUNTING
ACCESSORIES
DC PLUGS
(SEALED)
AC
CONNECTOR
METER /DRED
CONNECTOR
COMMUNI-
CATION
DATALOGGER
(OPTIONAL)
DOCU-
MENTS
1
1
1
2
pairs
1
1
1
1
1)
RS485/Wi-Fi/GPRS
(
optional).
3.2 Product Overview
The total size of EINSOLAR
5
-6.5V is 395 (width) × 328(height) ×154(depth) mm. It
has 2 pairs of PV input terminals and 2 communication ports. It has a LED/LCD
display for getting information and setting parameters at field.
The detail description is shown below:
5
4
V.
2
V.
2