background image

φ43-51

φ34-43

φ26-34

φ21-26

3.2 

AC Wire Assembly and Connection

Danger to Life due to High Voltages in the Inverter

Before connecting any electrical wires and components, please ensure the DC switch & AC circuit 

breaker are switched OFF and cannot be reactivated.

DANGER

DC Wire Assembly and Connection

Meeting the following requirements is mandatory. All warranty rights will otherwise be invalid.
3.3.1 Maximum open voltage of each string is less than 1100V.
3.3.2 Maximum short circuit current of each PV input is less than inverter allowable limit.
3.3.3 The string is well insulated to ground in all cases.
3.3.4 Make sure that the DC connectors have the correct polarity.
3.3.5 If the PV connectors are not assembled properly and locked into place, arc or overheat may be 
induced.

3.3

Step 1

Step 2

Step 3

1. The inverter and mounting bracket have been correctly installed. 2. The inverter’s exposed metal 

surface has a ground connection. 3. The resistance between PV arrays and ground is greater than 

1Mohm. 4. For any unused DC terminals, there are DC connectors inserted to the terminal and 

sealed with waterproof caps. 5. The grid voltage at the point of connection of the inverter is within 

the permitted range. 6. The AC circuit breaker must be correctly rated and wired. 7. The cable 

communication connectors have been correctly wired and tightened.
Startup
Switch on the DC switch after finishing the above checks, then switch on the AC circuit breaker. 

When there is sufficient DC power applied and the grid conditions are met, the inverter will start to 

operate automatically.

4. 

Commissioning

Please check if:

RS485/Smart Meter and DRED Connection

NOTICE 

For AS/NZS 4777, DRM0 is supported.

Make sure the cover and the communication cable gland has been mounted properly and adequately

Step 1

Step 2

Wi-Fi/GPRS Connection (Optional)

The stick is included in the scope of delivery as an option.
3.4.1 Tighten the stick into the COM1 port.Make sure the stick 
is securely connected.
3.4.2 For the connection and configuration of the Wi-Fi stick 
please refer to <Wi-Fi stick User manual> .

3.4

Step 3

Step 4

GUIDEWAY

2

3

1

4

Use the right sealing ring 

according to the diameter of 

the cable

1

2

3

4

Press the cable into the appropriate terminal.
Use a screwdriver to lock the cable to the 

corresponding position and tighten the 

screws on the box following the indicated 

sequence (1~4)

Assemble the box, 

threaded sleeve and swivel 

nut together

Step 1

Step 3

Step 4

Step 5

Step 6

click

click

7mm

7mm

PV1-F/UL-ZKLA/USE2

PV1-F/UL-ZKLA/USE2

Assemble the connectors

2.6-2.9 N·m

Positive

Negative

Assemble the 

D4 

cable ends

Positive terminal

Negative terminal

Crimp pliers to cable ends

Note: Don't crimp this part!

Step 2

Assemble the 

MC4 

cable ends

Positive terminal

Negative terminal

4-6mm

2

16mm

2

6mm

2

Approx. 10 mm

RS485 B1
RS485 A2
RS485 B2
RS485 A1

PIN1
PIN2
PIN3
PIN4

RS485 FOR COM2

Meter or DRED FOR COM3

COMLOAD/0
RS485 A
RS485 B
REF GEN/0

PIN1
PIN2
PIN3
PIN4

Pull out the plastic rivet 
and remove the plastic 
sheet

Please check if the cables are securely 

installed by pulling outwards

Strip off the insulation

Check the polarities of the PV strings

Check the open-circuit voltage is less 

than inverter input limit 1100V

Remove the waterproof 

caps from PV terminals

If there is an unused terminal, 

please seal it with the cap

Insert the connector into the terminal 

till you hear an audible click

For more information, please download the user manual and other technical documents at www.easelectric.es

EAS ELECTRIC SMART TECHNOLOGY, S.L.

Address: P.I. Codonyers, C/Principal, 4 46220 Picassent (Valencia, SPAIN)

Insert the wires into suitable ferrules (DIN 

46228) and crimp

Insert the crimped conductors accordingly into their corresponding terminals and tighten the screws

Assemble the locking cap, threaded 

sleeve and swivel nut together.

Screw the connector into the socket and tighten firmly.

Note: Please ensure that the connector has been correctly installed!

Содержание EINSOLAR36Y

Страница 1: ...mm Diámetro externo 5 8 mm 4 Meter DRED Cable para exteriores de par trenzado apantallado Sección transversal del conductor 0 14 1 5 mm Diámetro externo aprox 4 6 mm Especificaciones del cable 1 Display 2 Interruptor CC opcional 3 Terminal es FV 4 COM1 Wi Fi GPRS opcional 5 COM2 Terminal RS485 6 COM3 Meter Terminal DRED 7 Terminal CA 8 Segundo terminal de protección Dimensiones An Al Fo 580 x 435 ...

Страница 2: ...s extremos del cable MC4 Terminal positivo Terminal negativo 4 6mm 2 16mm 2 6mm 2 Aprox 10 mm RS485 B1 RS485 A2 RS485 B2 RS485 A1 PIN1 PIN2 PIN3 PIN4 RS485 para COM2 Meter o DRED para COM3 COMLOAD 0 RS485 A RS485 B REF GEN 0 PIN1 PIN2 PIN3 PIN4 Extraiga el remache de plástico y retire la lámina de plástico Compruebe si los cables están bien instalados tirando hacia fuera Retire el aislamiento Comp...

Страница 3: ...PV cable PV1 F Model recommended Conductor cross section 4 6 mm Cable outer diameter 5 8 mm 4 Meter DRED Two core outdoor shielded twisted pair cable Conductor cross section 0 14 1 5 mm Cable outer diameter approx 4 6 mm Cable Specifications 3 1 Mounting 1 LCD LED or LED 2 DC switch optional 3 PV Terminal s 4 COM1 Wi Fi GPRS Stick optional 5 COM2 RS485 Terminal 6 COM3 Meter DRED Terminal 7 AC Term...

Страница 4: ...ery as an option 3 4 1 Tighten the stick into the COM1 port Make sure the stick is securely connected 3 4 2 For the connection and configuration of the Wi Fi stick please refer to Wi Fi stick User manual 3 4 Step 3 Step 4 GUIDEWAY 2 3 1 4 Use the right sealing ring according to the diameter of the cable 1 2 3 4 Press the cable into the appropriate terminal Use a screwdriver to lock the cable to the...