E T X T S O L I T H I U M B A T T E R I E S
15
next (step 2) plug the charger power cord into AC outlet. The charger should startup and
go into the “Save” charging mode. If not contact EarthX technical support.
If using a Ground Power Unit (GPU), the current rating or current setting SHALL NOT be
more than the max charge rate stated on the battery label or in this manual. It is
recommended that a warning label is placed next to the GPU plug stating the max current
allowed.
Never charge a faulty battery (a battery that will not accept a charge or hold a
charge).
Never use the de-sulfate setting on your charger. Be sure the charger’s output
voltage level does not exceed 15V. If the charger does not display the voltage reading, then
use a voltmeter to check the voltage while charging.
If the battery gets hot while charging, discontinue charging and use.
Do not charge battery in temperatures above 140 degrees F (60C), or in direct
sunlight.
When charging a battery, place it on a non-flammable surface, and remove any
flammable items nearby.
For maximum battery and starting system life, do not crank an engine for
more than 15 seconds within any 1 minute period.
Storage
If the Aircraft is to be put in storage for an extended period of time (> 6 months),
disconnect the battery cable to eliminate drain from the Aircraft’s electrical system. A fully
charged battery can be put in storage for up to a year without charging, but should be
charged and inspected annually.
Our batteries can be stored at temperatures between
-
40°C to +70°C. Our batteries have no
liquid inside and will not freeze.
Do not incinerate or expose to open flames!