![EarthX ETX Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/earthx/etx-series/etx-series_installation-and-maintenance-manual_3391196016.webp)
E T X T S O L I T H I U M B A T T E R I E S
13
RS-232 Communications Connection
Voltage Monitoring (if applicable)
The table below shows the recommended user alerts based on voltages when in flight. This
pertains to existing equipment, and is not applicable if existing low or high voltage alerts do
not exist or are not adjustable.
The low charge level is very different from a lead acid battery, for a lithium battery is
completely drained at approximately 23V, and the normal resting voltage is 26.6V.
Note: this table pertains to existing voltage level warning equipment and is NOT associated
with the Fault monitoring LED.
Voltage
User Alert
>30V
High voltage warning
<27V
Alternator off-line alert
<25.5V
Low charge level warning
Accessory Parts
Additional 3/8” Tubing: 5239K15_G12 (12 feet length)
LED Kit: 11MM24
Replaceable Parts
There are no replaceable parts.
Installer Supplied Parts
Vent port