EarthPulse v.5Basic Скачать руководство пользователя страница 24

D) Initial 1-3 Hour Session: (please do baseline 

RBH test

)

1) Remove all metal parts from one electromagnet; refer to

 

magnet 

schematic

2) Place Air-Core electromagnet) with embossed “N”’s facing up on 

top of mattress under a thin pillow. Position your head to have the 

magnet directly at base of skull;

Initial session v.5Pro

Place second Sleep-Configured electromagnet on top of mat-

tress under base of spine (pad with folded towel if necessary 

for comfort); make sure CROSS-POLARIZING ring is -OFF-

3) Boot controller -> UP/DOWN arrows to set timer at 1 - 3 hours 

press SELECT/START display shows 9.6 Hz; SELECT/ENTER but-

ton to start run-time. Blue diode is blinking.

4) UP/DOWN arrows adjust amplitude; once program running with 

head on pillow, adjust amplitude up / down for comfort; place Earth-

Pulse™ beside you at comfortable distance. 

5) Get comfortable with magnet position(s); Close your eyes and 

enjoy your first session;

6) This session determines if 9.6 Hz will provide sleep or not. If NOT, 

you begin nighttime use with some lower frequency. 4.8 Hz, 2.4 Hz 

or something in between. 

7) If you have neurological disease you should do some basic be-

fore/after tests like handwriting sample, let family member watch/

video tape you walking, getting in/out of your favorite chair, walking 

backwards, turning around, making familial circles with fingers. You 

will want to repeat this initial session with more and more amplitude 

(adding core and base) every day until you plateau your performance.

7a) Wait 20 minutes after completion of initial session to re-

test mobility & finger dexterity.

BACK TO TABLE OF CONTENTS: 

 21

Содержание v.5Basic

Страница 1: ...v 5Basic v 5ProBasic USER MANUAL...

Страница 2: ...g of Modular Electromagnet 19 C Testing Electromagnet Output 20 D Initial 1 3 Hour Session Checklist 21 d1 Initial Session v 5 Pro Two Magnets 21 E Importance of Initial Session Choosing Initial Sleep...

Страница 3: ...ing Worse 34 2 Sleeping Same as Before 34 3 Dull Headache Upon Waking 35 4 Sleeping Better Then Deteriorates 35 5 Still Waking at Night for Toilet 35 6 Alternative Magnet Placement When Sleep Remains...

Страница 4: ...we will replace it w same or newer model for the above fees Misuse or Water damage see Warranty page on website for details For warranty service tech support or returns please email tech support slee...

Страница 5: ...iagnose treat cure or prevent any disease The information herein has not been evaluated by U S Food and Drug Administration or Health Canada Worldwide there are no governmental health agencies that re...

Страница 6: ...nds and family under most conditions as well For ease of use all links are in blue font italicized See TROUBLE SHOOTING AGITATION if sleep is worse than normal or if pain or other symptoms increase or...

Страница 7: ...r size of baby Please don t take a chance with nighttime use An hour or two power nap per day through a pillow to head is ad visable to help support neuroendocrine function and neurotransmis sion Safe...

Страница 8: ...igher amplitude applied all night could influence rate of growth Air core on floor under bed or crib for infants Child with stunted growth parameters should get as must amplitude as tolera ble Hot Ele...

Страница 9: ...er and more than compensate However If you have acute Lyme infection it is best to invest time in the Bob Beck Protocol Please read Electrify Your Lyme Disease article missing Both EP and Beck protoco...

Страница 10: ...respiration heart rate and brain activity slow thereby conserving energy that can be seques tered for repair hormone synthesis memory consolidation and im mune function Theta rhythm Associated with l...

Страница 11: ...s above low Beta 15 Hz occur when ex ited or fearful Mid to High Beta Gamma rhythm 15 Hz Mid Beta and then 20Hz High Beta with Fight or Flight Response and stress hormone production D Benefits of Natu...

Страница 12: ...nd must be consumed in the diet body also requires geomagnet ic vitamins supplied by Earth s Schumann waves and geomagnet ic fields to keep our mitochondria tuned properly so cells naturally maintain...

Страница 13: ...e function lung vol ume isn t going to increase more than 5 which is nowhere near the increase you should expect to see in your RBH Routine average increase of 20 in 7 days and up to 50 on aver age up...

Страница 14: ...d 1995 96 my shoulder started to fail again By 2001 I was beached not much surfing My timing and judgment was off so I wasn t having a good time in the water Around 2001 I could barely grip let alone...

Страница 15: ...urely and they d be dependent on Big Pharma as they aged This is why our great grandparents didn t know much about arthritis but our grand parents do I found OS researching how to detoxify the body fr...

Страница 16: ...lution please don t try and cut corners now Remember you can t build a brick wall without the bricks When rebuilding body parts make sure you have your nutritive components covered For neurological he...

Страница 17: ...y with PEMF reversing neuro disor ders It tastes awesome no need for the really expensive organic type but do use cold pressed Virgin which is unprocessed We pre fer organic everything A particularly...

Страница 18: ...er chair is perfect though you can do it in same comfortable chair or lying down Please keep body position consis tent from test to test You will need a watch or clock with a second hand nearby so you...

Страница 19: ...n you may find you like to exhale a little bit at a time to rid yourself of CO2 as I do the exhale process using this method may take from 20 40 seconds Consistency enables RBH test to accurately trac...

Страница 20: ...or two electromagnets ProBasic International pin adapter for your shipping location Padded carrying case 1 Please complete at least one Resting Breath Hold RBH test according to instructions BEFORE y...

Страница 21: ...ust frequency in 1 10 Hz steps Press SE LECT START to choose frequency and begin output 9 Blue diode blinks in time with magnetic pulse Controller is now active at 70 amplitude 10 UP DOWN arrows adjus...

Страница 22: ...BACK TO TABLE OF CONTENTS 19 SOUTH POLE NORTH POLE B AIR CORE 100 Gauss 130 G Nanosecond peak SLEEP 650 Gauss 950 G Nanosecond peak CROSS POLARITY 750 Gauss 1100 G Nanosecond peak...

Страница 23: ...v 5Pro Repeat steps above for both magnets At 100 amplitude coils reach 117 F 47 C at 10 hours runtime under feather pillow in Alert Mode maximum pulse rate If this com pletely safe level of heat mak...

Страница 24: ...ogram running with head on pillow adjust amplitude up down for comfort place Earth Pulse beside you at comfortable distance 5 Get comfortable with magnet position s Close your eyes and enjoy your firs...

Страница 25: ...ssion should be increased focus better balance and coordination better hand eye motor syn chronization Others might call it a grounding effect As capillaries dilate some will hear their heart beating...

Страница 26: ...area increase or decrease power as neces sary Other Techniques Move AIR CORE to under hips or attach AIR CORE to side of flat pillow and place so that magnet is facing soles of the feet from the foot...

Страница 27: ...for sleep by setting any frequency from 1 10 Hz to 10 Hz with timer setting up to 12 hours For ALERT use 12 14 1 Hz 12 Hz also has some strange harmonic resonations so be sure to try it rather than ju...

Страница 28: ...When Unable to Sleep or Fall Back to Sleep Hit SELECT ENTER button and program will reboot Set frequency lower Be sure to set timer again on your fall back reset so you get benefit of wake up program...

Страница 29: ...1 2 inches above the magnet or lie on top of coil directly or use Ace type elastic bandage to fix the coil in place far better where elbows knees shoulder feet hip is concerned Run magnet cable out t...

Страница 30: ...Pole will radiate in a fairly large perimeter around the North Pole field as pulse expands off leading edge or ring The sides and bottom become fairly weak static South Pole magnets Think of holding...

Страница 31: ...ce bandaged with DUAL POLARITY ring ON or OFF to hip knee ankle or foot or simply placed adjacent to the target area with DUAL POLARITY ring OFF It can also be placed under lumbar in contact with base...

Страница 32: ...utes of run time becomes a relatively strong static magnet with pulsed field pulsing through it Very effective applied locally Full 100 power setting will provide nice local source of heat that works...

Страница 33: ...g healthy tissue and fluids to South Pole while North Pole of electromagnet polarizes damaged tissue to North using a relatively strong 800 Gauss field thereby speeding exchange of fluids inflammation...

Страница 34: ...se of chair just touching your tail bone With v 5Pro place both the magnets on floor for feet or one on floor and one at tip of tail bone Do not use above solar plexus level on back of chair for examp...

Страница 35: ...levels as the week prior and count the increased reps per set Expect a routine 20 more reps per set The next workout add resistance to test your peak strength You should find you re able to lift 10 m...

Страница 36: ...ce on side more likely to be under that body part If small dog or cat just center it under the cushion where they like to lay Mobility where lacking will improve in 2 3 days No possibility of placebo...

Страница 37: ...enter of the core as pictured to be able to feel the pulse If no pulse is felt unplug the magnet and re plug firm ly Make sure to spin the jack while inserting into plug Consistency is key to conditio...

Страница 38: ...ove electromagnet under mattress aligned for hips until issue abates We ve had 96 year old retired doctor go from 5 times a night to 1 time per night in a few months If it worked for him it ll work fo...

Страница 39: ...touching it if running under bedding for full run time Trapped up against the body during long local applications the body acts as a heat sink so magnet never gets uncomfortably warm and works synerg...

Страница 40: ...r if tip or jack has gone bad Never operate controller at more than 12 volts or waveform WILL disintegrate Power supply specs input 100 240 volts AC output 12 volts DC Jack specs external diameter 5 5...

Страница 41: ...in power supply you should see LCD screen light momentarily if power supply is delivering sufficient voltage If controller screen characters become jumbled are missing or very light power off 5 sec an...

Отзывы: