SCWD-QS (12/16)
Page 9
Figure 3. Compressor Unit Clearance
Placement instructions for other pieces of equipment that make up the EarthLinked
®
System are
included with those pieces of equipment and are listed in this manual under
Equipment Manuals.
3) Refrigeration
After the EarthLinked
®
compressor unit and other system components are placed, the refrigeration
system tubing is run from the compressor unit to the other components, as appropriate. Figure 4
illustrates the refrigeration and electrical connection points for the compressor unit.
IMPORTANT!
EarthLinked
®
compressor units that provide space cooling shall be
equipped with an EarthLinked
®
Hybrid Cooling Module (HCM) when:
(1) Required by the performance tables; OR
(2) System is in a Cooling dominant application where soil thermal
conductivity is unknown or known to be poor (less than 1
BTU/hr.ft.°F). Examples of such soils are light dry soil, dry sand, peat
and organic soils, dry clay and hardpan; OR
(3) In any system where soil thermal conductivity is unknown or known
to be poor (see (2) for definition) and ambient outdoor temperatures
have exceeded the outdoor summer design temperature conditions
for a continuous system run time of at least 7 hours.
IMPORTANT!
EarthLinked
®
compressor units that provide space heating shall be
equipped with a Heating Performance Enhancement kit (HPE) when
required by the performance tables.
Содержание SCWD-024-1C
Страница 15: ...SCWD QS 12 16 Page 15 Figure 7 SCWD Compressor Unit Electrical Schematic Diagram 230 1 60...
Страница 16: ...SCWD QS 12 16 Page 16 Figure 8 SCWD Compressor Unit Electrical Schematic Diagram 230 3 60...
Страница 17: ...SCWD QS 12 16 Page 17 Figure 9 SCWD Hydronic Heating Cooling Water Heating Sytem Application...
Страница 18: ...SCWD QS 12 16 Page 18 Figure 10 SCWD Hydronic Heating Cooling Water Heating System Field Wiring Diagram...
Страница 20: ...SCWD QS 12 16 Page 20 Figure 11 SureStart Mode of Operation...
Страница 31: ...SCWD QS 12 16 Page 31 Figure 14 Disassembled Plug Connector...
Страница 38: ...SCWD QS 12 16 Page 38 Figure 23 SCWD Internal Flow Schematic...
Страница 39: ...SCWD QS 12 16 Page 39 Figure 24 SCWD Piping...
Страница 41: ...SCWD QS 12 16 Page 41 Figure 25 Evacuation of SCWD System...
Страница 43: ...SCWD QS 12 16 Page 43 Figure 26 Initial Charge of SCWD System...
Страница 45: ...SCWD QS 12 16 Page 45 Figure 27 Final Charge of SCWD System...
Страница 48: ...SCWD QS 12 16 Page 48 Figure 31 Start Up Process...
Страница 60: ...SCWD QS 12 16 Page 60 Figure A1 SCWD Compressor Unit Electrical Schematic Diagram No SureStart 230 1 60...
Страница 61: ...SCWD QS 12 16 Page 61 Figure A2 SCWD Compressor Unit Electrical Schematic Diagram No SureStart 230 3 60...