IMPORTANT

For all valves, the air 

MUST

 be purged from the gas line before the pilot will light and burn properly.  The 

time needed to purge will depend on the length of the gas line to the unit and the amount of time since 
the unit or gas line was last used. It may take several minutes before all the air is purged and the pilot 

will light and burn properly. Reference the LIGHTING INSTRUCTIONS section in this manual.

The ISO-FLAMES gas log set must be installed by a qualifi ed professional service technician. Instructions 
must be followed carefully to ensure proper performance and full benefi t from the gas log set. 

Check to be 

sure the log set is designed and labeled for the type of gas (natural or propane gas) supplied to the 
fi replace. Fireplace fl oor must be level, clean, and smooth.

WARNING:  Failure to position the parts in accordance with these diagrams or failure to use only 

parts specifi cally approved with this appliance may result in property damage or 
personal injury.

BURNER INSTALLATION

1. 

MAKE SURE THE FIREPLACE GAS SUPPLY IS 

TURNED OFF.

2. 

Place the burner system in the fi replace. Center the 

burner toward the rear of the fi replace. (Reference Fig. 
8-2 for orientation.)

3.

  Locate the gas-supply stub inside the fi replace and 

remove the cap, if attached (see Fig. 8-1).

4.

  Use pipe compound resistant to all gases or Tefl on 

tape to attach the supplied elbow to the gas-supply 
stub. Then attach the fl ex connector (coming off of the 
burner system) to the elbow (see Fig. 8-1).

5.

  LEAK TEST: Turn on the fi replace gas supply, and test 

at all connections for leaks using the appropriate soapy 
water solution. If bubbles appear, a leak is present. Turn 
off the gas and tighten at all connections. Repeat until 
no leaks are present. If a leak persists, turn off the gas 
supply and contact the local gas company or dealer. 
NEVER USE A FLAME TO CHECK FOR LEAKS.

6.

  Place the remote receiver box at the right front corner 

of the fi replace. Be sure to run its wire in between the 
two grate legs on the right side of the burner system, 
and that the wire remains away from the burner system 
and its fl ame during operation. (See Fig. 8-2.)

Note:

  Alternately; the box can be placed at the rear 

right corner of the burner system. Be sure 
to place its wire towards the back so that it 
remains away from the burner system and its 
fl ame during operation. (See Fig. 8-3.)

If optional wall switch was purchased separately; refer 
to the instructions supplied with the wall switch for 
installation.

Gas-supply stub

Elbow

Flex connector

Fig. 8-1

 Connect gas supply

Fig. 8-2

 Remote receiver box location

Fig. 8-3

 Alternate receiver box location

Содержание PET-24N

Страница 1: ...e burned in a fireplace where a decorative appliance is installed FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES IMPORTANT READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OF THE LOG SET STADIUM BURNER SET OWNER S MANUAL Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Open a window Do not...

Страница 2: ...des pertes humaines Note des Plein carburants ne seront pas brûlés dans une cheminée où un appareil décoratif est installé POUR L INSTALLATION EN CHEMINÉES BRÛLANTES DE COMBUSTIBLE SOLIDE MANUEL DU PROPRIÉTAIRE Ne stockez pas ou n employez pas l essence ou d autres vapeurs et liquides inflammables à proximité de ceci ou d aucun autre appareil CE QUI À FAIRE SIVOUS SENTEZ LE GAZ Ouvrez une fenêtre ...

Страница 3: ...CATIONS 6 DAMPER CLAMP INSTRUCTIONS 6 BURNER PARTS LIST 7 BURNER INSTALLATION 8 GLOWING EMBER LAVA COAL PLACEMENT 9 LOG PARTS LIST 9 LOG PLACEMENT 10 INSTALLING REPLACING BATTERIES 11 LIGHTING INSTRUCTIONS 13 CLEANING AND SERVICING 14 FLAME DESCRIPTION 14 TROUBLESHOOTING 15 CUSTOMER SERVICE WARRANTY 17 WARRANTY CARD 18 ...

Страница 4: ... intérieur minimum Si la ligne de gaz est plus longue que 20 une ligne de plus grand diamètre peut être nécessaire J Les estimations d entrée montrées en Btu par heure sont pour des altitudes jusqu à 2 000 pi Pour des altitudes au dessus de 2 000 pi référez vous au code national de gaz de carburant ou entrez en contact avec le fabricant avant d installer ce produit K Cet appareil à gaz et son clap...

Страница 5: ...Gas supply pipe must be 1 2 minimum interior diameter If the gas line is longer than 20 a larger diameter line may be necessary J Input ratings shown in BTU per hour are for elevations up to 2 000 ft For elevations above 2 000 ft refer to the National Fuel Gas Code or contact manufacturer before installing this product K This gas appliance and its main gas valve must be disconnected from the gas s...

Страница 6: ...il to provide the permanent vent opening listed in the table found above have a permanent stop installed remove the damper blade or have the damper cut to provide the minimum permanent opening required Note These are minimum damper opening specifications The damper must be completely opened when operating this gas appliance to achieve the best ventilation possible Fig 6 2 Damper clamp Set screw No...

Страница 7: ...ly 3 Remote receiver box 4 Remote transmitter 5 Control valve 4 1 Replacement parts can be ordered from your local Earthcore dealer ITEM NO DESCRIPTION 6 Flex connector 7 Control module 8 Lava coals 9 Damper clamp 10 Elbow 1 2 male flare x 1 2 NPT 24 Model Shown 8 9 Bottom view Heat sensor Pilot Electrode 2 3 5 7 10 6 ...

Страница 8: ...as supply stub inside the fireplace and remove the cap if attached see Fig 8 1 4 Use pipe compound resistant to all gases or Teflon tape to attach the supplied elbow to the gas supply stub Then attach the flex connector coming off of the burner system to the elbow see Fig 8 1 5 LEAK TEST Turn on the fireplace gas supply and test at all connections for leaks using the appropriate soapy water soluti...

Страница 9: ...e unsafe operation LAVA COALS DECORATIVE Spread the supplied lava coals see BURNER PARTS LIST on the floor of the fireplace around the front and sides of the burner system The lava coals may be placed around and on top of the remote receiver box Leave the front of the box clear for control access Note DO NOT place any lava coals on the burner system or behind it GLOWING EMBER LAVA COAL PLACEMENT N...

Страница 10: ...red here to aid in the log placement procedure 1 Prior to log placement be sure the glowing embers were placed as discussed in the GLOWING EMBER PLACEMENT section 2 Set the bottom rear log 1 at the rear of the grate Fig 10 1 Center the log with its back up against the burner tabs 3 Set the bottom left and right logs 2 3 at the front of the burner with the charred ends facing inward Leave a small g...

Страница 11: ... BOX BATTERIES To access the batteries locate the remote receiver box and turn it over The exposed D battery pack is for electronic ignition Replace the old batteries with 2 new D batteries See Fig 11 1 Slide open the lid on the remote receiver to expose the batteries Replace the old batteries with 4 new AA batteries See Fig 11 1 Replace the lid When battery replacement is complete properly place ...

Страница 12: ...mée et écurie Après une brève durée le pilote allumera alors le brûleur principal ATTENTION SI LE BRÛLEUR NE MET PAS À FEU À MOINS DE 20 SECOUNDS ARRÊTEZ L ATTENTE 5 MINUTES ALORS RÉPÉTEZ LES ÉTAPES 1 À 3 CI DESSUS Normalement lepilotedevraitresterLit S ilsort répétezl étape2ou3 Si le pilote ne restera pas allumé après que plusieurs essais tournent le récepteur à AU LOIN et contactent un fournisse...

Страница 13: ...table after a short time the pilot will then light the main burner CAUTION IF THE BURNER DOES NOT IGNITE WITHIN 20 SECONDS STOP WAIT 5 MINUTES THEN REPEAT STEPS 1 THRU 3 ABOVE Normally the pilot should remain lit If it goes out repeat step 2 or 3 If the pilot will not stay lit after several tries turn the receiver to OFF and contact a qualified professional service technician or gas supplier In ad...

Страница 14: ...uctions In addition a periodic examination and cleaning of the solid fuel burning fireplace venting system should be conducted by a qualified professional service technician Any safety screen or guard removed for servicing must be replaced prior to operating this appliance TO CLEAN THE LOG SET 1 Remove the log set and embers Use a vacuum cleaner to remove loose particles from all surfaces of the l...

Страница 15: ...sparking when activated Note You may need to turn or press ignitor several times to ignite pilot See LIGHTING INSTRUCTIONS for your control valve C Ignitor electrode wire loose C Check wiring and reconnect any loose wiring D Gas supply off manual shutoff valve closed D Turn on gas supply or open manual shutoff valve E Air in gas line E Bleed the gas supply line and repeat LIGHTING INSTRUCTIONS unt...

Страница 16: ...he burner system immediately and completely including pilot following the steps in the LIGHTING INSTRUCTIONS section Then call your dealer F Adding any accessories to log sets F Shut down log set and take off any logs or accessories that do not belong with the set PILOT WILL NOT STAY LIT A Valve won t hold A Contact your dealer for instructions on replacement B Pilot hood not aimed at thermocouple...

Страница 17: ...s directly at 800 642 2920 It is important for you to register your ISO FLAMES gas log system with Earthcore Please complete the warranty card included in this manual on the following page 1 The ISO FLAMES gas log burner has a one year warranty against any performance defects 2 The ISO FLAMES gas logs have a one year warranty against breakage except breakage due to mishandling or negligence 3 If t...

Страница 18: ...__________________________________________________________________ Gas Log Burner Size 24 30 Circle One Gas Control Valve Type remote control safety pilot Gas Type Natural Gas or Liquid Propane LP Circle One Comments Purchased from Name _______________________________________________________________________ City State ____________________________________________________________________ PhoneNumber...

Отзывы: