Earth Stove ES2100 Скачать руководство пользователя страница 26

26

Secure Temp® Factory-Built Chimney

6” Secure Temp ASHT and Secure Temp G-ASHT

Cat. No.

Model

Description

Pc. / Container

Lengths and Fittings

6L8

6L8

LENGTH 6” X 8” 

1

6L12

6L12

LENGTH 6” X 12” 

1

6L18

6L18

LENGTH 6” X 18” 

1

6L24

6L24

LENGTH 6” X 24” 

1

6L36

6L36

LENGTH 6” X 36” 

1

6L48

6L48

LENGTH 6” X 48” 

1

6LA

6LA

ADJUSTABLE LENGTH, 12” 

1

6TI

6TI

INSULATED TEE (TCS INCLUDED)

1

6TCS

6TCS

INSULATED SS TEE CAP (INCLUDED 

WITH TI)

10

6TB

6TB 

BASE TEE GALVANIZED (TC IN-

CLUDED)

1

6TBS

6TBS 

BASE TEE STAINLESS (TCS IN-

CLUDED)

1

6TBD

6TBD

BASE TEE GALVANIZED DOUBLE (TC 

INCLUDED)

1

6TC

6TC

BASE TEE CAP GALVANIZED

10

6TCI

6TCI

INSULATED TEE CAP (USE WITH 

SME SUPPORT)

5

6TCP

6TCP

DRAIN TEE CAP (USE WITH SME 

SUPPORT)

5

6E15

6E15

INSULATED ELBOW 15 DEGREE

2

6E30

6E30

INSULATED ELBOW 30 DEGREE

1

Aluminum Zinc Coated Steel (Lengths and Fittings)

6GL8 

6GL8

LENGTH 6” X 8” 

1

6GL12

6GL12

LENGTH 6” X 12”

1

6GL18

6GL18

LENGTH 6” X 18”

1

6GL24

6GL24

LENGTH 6” X 24”

1

6GL36

6GL36

LENGTH 6” X 36”

1

6GL48

6GL48

LENGTH 6” X 48”

1

6GLA

6GLA

ADJUSTABLE LENGTH, 12”

1

6GTI

6GTI

INSULATED TEE (TCS INCLUDED)

1

6TCS

6TCS

INSULATED SS TEE CAP (INCLUDED 

WITH GTI)

10

6GE15

6GE15

INSULATED ELBOW 15 DEGREE

2

6GE30

6GE30

INSULATED ELBOW ALUM-ZINC 30 

DEGREE

1

Supports

6UP

6UP

FLUE EXTENSION 

10

PS

PS

SqUARE CATHEDRAL SUPPORT 

EXTENSION 

1

6SSC

6SSC

SqUARE CATHEDRAL SUPPORT W/

COUPLER 

1

6SSAC

6SSAC

ADJUSTABLE SqUARE CATHEDRAL 

SUPPORT w/COUPLER

1

6SFC-1

6SFC-1 FINISHING SUPPORT W/COUPLER

1

Cat. No.

Model

Description

Pc. / Container

Supports (continued)

6SM

6SM

TEE SUPPORT

1

6SMA

6SMA

GALVALUME ADJUSTABLE TEE 

SUPPORT (2” TO 6”)

1

SO

SO

OFFSET SUPPORT / WALL SUP-

PORT

10

ST

ST

ROOF SUPPORT

10

6SD

6SD

FLOOR SUPPORT

5

6SP

6SP

ANCHOR PLATE

10

Braces and Firestops

6BF

6BF

FIRESTOP

10

6RSM30

6RSM30 ANGLED FIRESTOP - 30 DEGREE

6RS

6RS

RADIATION SHIELD

5

6RSA2

6RSA2 

2PC INSULATED ATTIC RADIATION 

SHIELD

1

6ARSA

6ARSA

ADJUSTABLE INSULATED ATTIC 

RADIATION SHIELD

1

6RSI

6RSI

INSULATED RADIATION SHIELD

1

6RSM-1

6RSM-1

INSULATED WALL THIMBLE

1

6RSMI30 6RSMI30 30-DEGREE INSULATED

RADIATION SHIELD

1

BS2

BS2

UNIVERSAL ROOF BRACE

1

BM

BM

UNIVERSAL WALL BAND

10

6BH

6BH

GUY WIRE BAND (WIRE NOT 

INCLUDED)

10

6FR

6FR

FLAT ROOF FLASHING

3

6FAR

6FAR

ADJUSTABLE ROOF FLASHING - 

1/12- 7/12

3

6FARA

6FARA

ADJUSTABLE MALLEABLE ALUMI-

NUM ROOF FLASHING 1/12 - 7/12

6FBR

6FBR

ADJUSTABLE ROOF FLASHING - 

8/12- 12/12

3

6FBRA

6FBRA

ADJUSTABLE MALLEABLE ALUMI-

NUM ROOF FLASHING 8/12 - 12/12

6FBBR

6FBBR

ADJUSTABLE ROOF FLASHING 

12/12 - 21/12

3

6FPR

6FPR

PEAK ROOF FLASHING 1/12 -7/12

3

6FPBR

6FPBR

PEAK ROOF FLASHING 8/12 -12/12

3

6FC

6FC

STORM COLLAR

10

Chimney Termination

6CC

6CC

RAIN CAP

1

PE

PE

UNIVERSAL SPARK ARRESTER 

BAND

10

Chimney Accessories

6PF-1

6PF-1

DECORATIVE TRIM

5

6PB

6PB

DECORATIVE COLLAR

25

6PA

6PA

BLACK PIPE ADAPTOR

1

6PD-1

6PD-1

FINISHING CONE

1

Installation Kits

6EK-2

6EK-2

EXTERIOR KIT (INCLUDES 1 TI, 1 

TCS, 1 SMA, 1 RSM, 1 PB, 1 UP, 1 

DqDH, 1 PE)

1

6IK-1

6IK-1

INTERIOR KIT (INCLUDES 1 SFC, 1 

RSA2, 1CC)

1

VENTING COMPONENTS - MODEL ES2100

Содержание ES2100

Страница 1: ...n the same room as appliance Free Standing EPA Certified Wood Burning Stove P N 507108 01 Rev NC 08 2012 A French manual is available upon request Order P N 506223 52 Ce manuel d installation est disp...

Страница 2: ...on 3 Testing Information 4 Draft Requirements 4 Selecting the Proper Venting System 4 Negative Pressure Warning 5 Clearances to Combustibles 6 7 Floor Protection 6 Chimney and Connector 6 Components 6...

Страница 3: ...g season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney sweep Do not attempt to burn out heavy creosote accumulations with a...

Страница 4: ...capabilities of the appliance The damage that occurs from overfiring is not covered under the manufacturer s limited warranty Also see Troubleshooting on Page 22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO...

Страница 5: ...ommon household appliances which exhaust air from the home such as a furnace heat pump air conditioner clothes dryer exhaust fans fireplaces and other fuel burning appliances Also the combustion proce...

Страница 6: ...t connector pipe may be double wall single wall or single wall with shield as listed above This appliance may be vented into a code approved masonry chimney with flue liner WARNING CHIMNEY CONNECTOR M...

Страница 7: ...2 9 5 8 8 6 15 37 5 8 46 3 4 34 7 8 16 0 96 57 1 2 305 232 495 245 200 152 381 956 1188 886 406 0 2438 1461 CANADA inches millimeters PIPE INSTALLATION A 3 B 1 C 3 D 1 E 8 F 1 G 3 H 2 I 6 J 2 K 7 L 5...

Страница 8: ...nd photographs are not to scale consult installa tion instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice Approved...

Страница 9: ...r Single Wall Connector Pipe Figure 6 Typical Installation Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single wall stove pipe must not pass through attics clos...

Страница 10: ...hat it either be cemented to the masonry or be installed without cement in a thimble connected to the masonry wall When the connector is inserted into a thimble the joint must be tight enough so that...

Страница 11: ...n shall be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from con nector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and...

Страница 12: ...Duct length should be kept to a minimum b The air intake register must not be installed more than ten 10 feet 3050 mm above the base of the stove c The fresh air must come from outside the house The a...

Страница 13: ...be slightly smaller to adjust for steel and firebrick tolerances beyond our control Be sure to measure and mark bricks with their numbers when removing Warning If the bricks are not installed exactly...

Страница 14: ...oards are properly installed FOR YOUR OWN PROTECTION AND INSURANCE PURPOSES HAVE YOUR CHIMNEY AND CONNECTOR PIPE INSTALLATION INSPECTED BY YOUR LOCAL BUILDING CODE AUTHORITY OR FIRE MARSHAL BEFORE STA...

Страница 15: ...h the door closed Operate only with the door shut tightly at all times except when loading wood and possibly on start up to establish a draft Never leave the unit unattended while the front door is op...

Страница 16: ...the amount of draft present DO NOT LEAVE THE STOVE UNATTENDED WHILE THE FRONT DOOR IS SLIGHTLY OPEN CAUTION Do Not alter the adjustment range of the draft control for increased firing for any reason O...

Страница 17: ...was the need to keep it slightly open during start up 6 For best results use smaller pieces of wood to get the stove or fireplace insert temperature very high before loading larger wood for sustained...

Страница 18: ...ill need to have sufficient temperatures inside the firebox for thorough combustion The best method for determining if you have sufficient temperatures is to watch the brick lining in your firebox Whe...

Страница 19: ...he stove is burned with the blower opening unobstructed Figure 24 The optional blower is controlled by a Dial a Temp see Figure 24 It contains an On Off line switch with variable speed control from lo...

Страница 20: ...ing of your new Earth Stove appliance Maintenance GLASS REPLACEMENT INSTRUCTIONS Refer to Figure 26 Step 1 Remove Door Assembly Remove the upper and lower hinge pins by pressing the bottom of each hin...

Страница 21: ...Door Latch Adjustment Instructions 1 Using a 5 32 hex wrench remove the side heat shield by removing 3 screws on the back 2 screws on the bottom and 1 screw at the top front corner 2 With the door op...

Страница 22: ...Pages 17 and 21 3 See Poor Draft section above and Cleaning Glass on Pages 4 and 21 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OP...

Страница 23: ...escription H8890 Right side heat shield H8891 Left side heat shield H8892 Back heat shield H8893 Door back w pins H8894 Door channels w nuts H8895 Glass H5640 Glass gasket kit 8 4 H5639 Door rope kit...

Страница 24: ...Ducting Kit includes 4 insulated flex x 10 long AND H8874 OUTAIRKIT ES Outside Air Panel and Air Channel Kit includes rear pedestal panel and side and front air channels MISC H8159 TSPK B Touch Up Pa...

Страница 25: ...LENGTH 3 34 2 6DT 6DT TEE TEE CAP INCLUDED 4 6DE45 6DE45 ELBOW 45 DEGREE 4 6DE90 6DE90 ELBOW 90 DEGREE 4 6DMA 6DMA MASONRY ADAPTOR 1 6UP 6UP FLUE EXTENSION 10 6DAB 6DAB STOVE ADAPTOR 8 6DLW7 6DLW7 IN...

Страница 26: ...UPLER 1 6SFC 1 6SFC 1 FINISHING SUPPORT W COUPLER 1 Cat No Model Description Pc Container Supports continued 6SM 6SM TEE SUPPORT 1 6SMA 6SMA GALVALUME ADJUSTABLE TEE SUPPORT 2 TO 6 1 SO SO OFFSET SUPP...

Страница 27: ...e Wall Simple Paroi Residential R sidentielle Double Wall Double Parois Residential or Mobile Home PIPE INSTALLATION Single Wall Simple Paroi Residential R sidentielle Double Wall Double Parois Reside...

Страница 28: ...ve the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of...

Отзывы: