EN
13
HV1900
Malfunction
Cause
Remedy
Too much fog of
coating material
(Overspray)
•
Distance to the object too large
•
Too much coating material applied,
material volume setting too high
•
Amount of air too high
➞
Reduce distance
➞
Alter material volume
adjuster
➞
Alter material volume
adjuster
Paint in the
ventilating hose*
•
Diaphragm soiled
•
Diaphragm defective
➞
Clean the diaphragm
➞
Replace the diaphragm
Poor covering
capacity on the
wall
•
Spray material is too cold
•
Highly absorbent surface or paint
with poor covering capacity
•
Distance too large
➞
The material you are
spraying should be at
room temperature
➞
Cross spray (Fig. 8)
➞
Closer to the object
* Models - HV4500 and HV5500.
23. Technical Data
Technical Data
Power source
230 V
~ 50 Hz
Power consumption
400 W
Double insulation
Air hose length
2.7 m
Weight
2.7kg
Содержание SPRAY SYSTEM HV 1900
Страница 1: ...Spraystation HV1900 Operating Manual EN...
Страница 2: ...HV1900 1 6 3 2 1 4 7 3 A Spraystation HV1900 Operating Manual EN B A 2 5A 5B B...
Страница 3: ...HV1900 4 5 A B C 7 A C 20 30 cm B 6...
Страница 4: ...HV1900 A B 12 8 2 1 10 NEED IMAGE NEED IMAGE 1 2 4 6 5 9 7 8 3 1 2 3 4 11...
Страница 21: ...EN 17 HV1900...