background image

CREATED ON: May 24, 2018

 

 

 

                                                 

Instruction Manual

 

 

 

 

 

ST-4M1 V2.0 

SEQUENTIAL TIMER WITH 4 CHANNELS

 

  

                                         

 

                            

 

                                                                      

                                                            

EAPL

 

 

 

                                                                                                     
Introduction

  

On power application and continuous shorting of S1 & S2 terminals, 
Timing sequence of the 1

st

channel (CH1) is initiated by switching the 

relay ON and ON-time starts. At the end of the ON-time relay goes 
OFF and OFF-time starts. After completion of the OFF-time CH2 relay 
comes ON and ON-time starts followed by OFF-time. This sequence 
continues for rest of the channels. After the OFF-time of CH4, again 
the CH1 relay comes ON and this cycle keeps repeating till the power 
is interrupted. 

 

 
 
 
 
 
 
 
 

 

 
 
 
      

 

        Box Accessories

 

       One (1) ST-4M1 SEQUENTIAL TIMER WITH 4 CHANNELS 
       One (1) Instruction manual. 

 

Safety Precautions

 

Read and follow all the safety precautions and instructions before 
installing and working with the equipment. 

 

S1- S2 start signal shall be applied. 

 

Shorting of S1-S2 shall be potential free; applying power to these 
terminals will damage the timer permanently. 

                           !   

DANGER 

HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH 

 

Apply appropriate personal protective equipment(PPE) and follow safety 
work practices 

 

Only qualified electrical workers should install this equipment. Such work 
should be performed only after reading this entire set of instructions. 

 

If the equipment is not used in the manner specified by the 
manufacturer, the protection provided by the equipment may be 
impaired. 

 

NEVER work alone. 

 

Turn OFF all power supplying the Sequential timers and the equipment in 
which it is installed before working on it. 

 

The successful operation of this equipment depends upon proper 
handling, installation and operation. Neglecting fundamental installation 
requirements may lead to personal injury as well as damage to electrical 
equipment or other property. 

 

NEVER bypass external fusing.

 

 

 

Source Voltage should not exceed specified limits. It will damage the 
unit beyond repair 

 

Do not apply voltage terminals. 

 

Before performing Dielectric or Megger testing on any equipment in 
which the Sequential timers is installed, disconnect all the input and 
output wires to the Sequential timers. High voltage testing may damage 
electronic components contained in the Sequential timers. 

Failure to follow these instructions will result in death or serious injury.

 

 

EAPL is not responsible for any consequential damages arising out of

 

use 

of our products, though the technology is cautiously chosen and 
implemented like any other well designed good electric device. 

Tools and Fasteners 

Kindly use star – type screw driver for tightening the screws. 

 

NOTE:

 Installation should include a disconnecting device, like switch or 

circuit breaker, with clear ON/OFF markings, to turn-off the auxiliary 
supply (control power).The disconnecting device should be within the 
reach of the equipment and the operator

Dimension 

 

 

 

 

 

 

 

 

Note: All Dimensions are in mm. 

 
  Front Panel          

 

 

    

 

 

 

 

 

 

 

Terminal Details 

A1,A2 : Source 

S1-S2  : Open - Stop Signal 

              Continuous – Timing Initiation. 

C1,NO1 : Control output 1 

C2,NO2 : Control output 2 

C3,NO3 : Control output 3 

C4,NO4 : Control output 4 

HOLD MODE: Continue the timing after resumption of interrupted power. 

RESTART MODE: After the resumption of interrupted power operation starts 

from the CH1 or waits for the start signal. 

 

     OD RK AN 050011

 

REV 02/24-05-2018

 

 

Page 1 of 2 

 

    

 