Chapter   1 Introduction 

 

 
The 2200L is a broadband solid state amplifier covering the frequency spectrum from 10 
KHz  to  12  MHz.  It  is  rated  at  200  watts  of  RF  power  with  low  harmonic  and 
intermodulation  distortion.  Over  300  watts  of  saturated  power  can  be  produced  with 
increased distortion products. A highly linear Class A design, the 2200L will amplify inputs 
of  AM,  FM,  SSB,  pulse  and  any  complex  modulation  signals.  The  amplifier  has  53  dB 
gain,  it  is  unconditionally  stable  and  will  not  oscillate  even  with  combinations  of 
mismatched source and load impedance. It is protected against failure due to output load 
mismatch and/or overdrive. 
 
RMS forward and reverse powers are monitored by a front panel meter. An integral power 
supply permits operation from 115/230 single phase AC power. 
 

1.2     INSTRUMENTATION IDENTIFICATION 

 
Each amplifier is identified by a serial number tag on the back panel of the unit. Both the 
model number and the serial number should be quoted to identify specific unit.  
 

1.3      SPECIFICATIONS 

 
Physical and electrical specifications are listed in Table 1-1 below 
 

Содержание 2200L

Страница 1: ...thout notice Jan 2006 Revision B 1 2200L Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extreme caution in handling these volta...

Страница 2: ...operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must be returned to E I freight cost t...

Страница 3: ...FM SSB pulse and any complex modulation signals The amplifier has 53 dB gain it is unconditionally stable and will not oscillate even with combinations of mismatched source and load impedance It is p...

Страница 4: ...nditions without damage POWER OUTPUT METER True RMS power detection 3 of full scale accuracy POWER REQUIREMENTS 85 264 VAC 47 63 Hz SIZE 5 1 4 X 16 5 X 18 1inches 13 4 X 41 9 x 46 0 cm WEIGHT 52 5 pou...

Страница 5: ...V rms indicated maximum input voltage is 5 times the level of the input signal required to achieve maximum output Input voltages in excess of 2 volts peak may permanently damage the instrument iii Con...

Страница 6: ...icted If the fault persists please contact Field Service 2 3 3 RS 232 Interface The 2200L features a standard RS 232 serial interface suitable for connection to a PC or host system The communication p...

Страница 7: ...nt end The output signal of the MMIC is coupled to the gate of transistor Q1 The further amplified signal appearing at the drain of Q1 is coupled to the input of Q2 This is transformed to 50 and fed t...

Страница 8: ...nd 24V J1 PS2 PS_48V 48V 110VAC_line 110VAC_neutral earth_gnd SELV 5V Inhibit SELV 5V ret Inhibit_ret DC_ok DC_ok_ret 48V_ret 24V 24V_ret 48V A1 Fan 24V Ret 1 12 05 P1 5 9 4 8 3 7 2 6 1 J2 24V_ret 48V...

Страница 9: ...o a power level of 13dBm This chapter therefore deals only with certain fundamental procedures for fault location S1 VHF_splitter_20W RF_in RF_out1 RF_out2 50 ohm 34dBm 48V_ret 48V_ret 24V_ret 2100L S...

Страница 10: ...or c Adjust the output level of the sweep generator so that a 50 ohm video detector connected at the output of the unit will not be damaged by excessive power output Reference section 4 4 1 for set up...

Страница 11: ...the oscilloscope to DC Time cm to Ext X and gain to l0mv cm b Set the sweep generator to the video sweep mode with the start frequency at 10 kHz and the sweep width to 12 MHz c Disconnect the 2200L f...

Страница 12: ...as shown on the oscilloscope 4 4 2 Measurement of Harmonics Figure 4 2 1 Equipment Required a Sweep Signal Generator b Calorimetric Power Meter HP435B c Spectrum Analyzer d Attenuator 30dB e Coupler...

Страница 13: ...ng parts to relieve these of unnecessary shock Close the carton securely and seal with durable tape Mark the shipping container FRAGILE to ensure careful handling Chapter 5 Safety Do not attempt to op...