background image

 

The material contained in this document is the property of Electronics & Innovation Ltd., it is 
subject to change without notice.  
 
May 2019                                                                                                                             Revision C 
 

are fed from the outputs of the oscillator and ramp generator.  The output of the 
bridge  is  then  fed  through  the  low  pass  filter  network  to  recover  the  signal 
waveform; then fed to the N connector at the output.  
 
There is a current limit protection circuit to protect the unit, in addition to the input 
drive  clamp.  Current  and  voltage  samples  are  taken  from  the  output  and  fed  to 
the BNC connectors on the front panel for monitoring purposes. 
 

                

 

 
 
The AC supply is fed through an EMI filter to two power supplies that convert the 
AC to 90 Vdc for the amplifier. one DC supply is used for 45 Volt required for the 
cooling fan and additional DC-DC converters to supply the fl 15 V for the 
gate drivers and +/- 15 volt rails, for the control circuitry. 
 

Содержание 1000S04

Страница 1: ...Ltd it is subject to change without notice May 2019 Revision C 1 1000S04 Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extrem...

Страница 2: ...rts so as to render the unit fully operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must...

Страница 3: ...of AM FM SSB pulse and any complex modulation signals within the bandwidth of the amplifier The amplifier has 60 dB gain it is unconditionally stable and will not oscillate even with combinations of...

Страница 4: ...240 VAC 50 60 Hz SIZE 3 1 4 X 17 X 21 9 inches 8 27 X 43 4 x 55 7 cm WEIGHT 40 pounds 18 2 kg CONNECTORS N type power BNC sample ports OPERATING TEMPERATURE 0 40 C RACK MOUNTING 2 U Chassis Chapter 2...

Страница 5: ...ction between the supply and the rear of the unit 2 3 1 Proceed as follows i Ensure that there is at least 3 or 7 5 cm clearance at the rear of the unit for air flow ii Connect the output via a 50 ohm...

Страница 6: ...t the output There is a current limit protection circuit to protect the unit in addition to the input drive clamp Current and voltage samples are taken from the output and fed to the BNC connectors on...

Страница 7: ...he equipment being returned for servicing it should be packed in the original shipping carton and packing material If this is not available wrap the instrument in heavy paper or plastic and place in a...

Страница 8: ...ver heat and cause eventual failure if the unit is operated without the cover in place N B Removal of cover will void warranty Ensure that the load is connected to the output prior to connecting the R...

Отзывы: